Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹11.1 L+₹2.7 L (31.7%)Accepted-Finance 638 GROUND FLOOR WEST GURU ANGAD NAGAR LAXMI NAGAR LAXMI NAGAR EAST DELHI DELHI 110092 UDYAM DL 02 0031392 | EAST DELHI | DELHI | 110092 | L2 | Accepted-Finance OK | |
| 3 | L3₹11.5 L+₹3.0 L (36.0%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | Rejected-Technical | - | Rejected-Technical as per NIT conditon no. 05 | |
| 5 | Rejected-Technical CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | - | Rejected-Technical reffered to condition no. 23 |
| Sl No | Description | Qty | Unit | SAI TRADING CORPORATION L2 | RUDRA ALLIANCE L3 | paramount systems L1 |
|---|---|---|---|---|---|---|
| 1.01 | Dismantling of defective 1000 Sq mm single core cable from the main LT cable from the main LT panel after suitable checking live parts to ensure safety of the working persons & other items requiring change in the panel as required at site. | 2 | Jobs | 50,600 ₹59,708 | 71,200 ₹84,016 | 2,000 ₹2,360 Lowest |
| 1.02 | Supply of 1000 mm sq x 1 core aluminium armoured cable 1.1 kV grade.
Make : Havells/Grandley/ Gloster. | 220 | Mtr | 5,87,400 ₹6,93,132 | 5,94,000 ₹7,00,920 | 3,30,000 ₹3,89,400 Lowest |
| 1.03 | Laying of 1000 sq mm sq cable using necessary clamps, hardware, brass compression glands, lugs etc as required at site | 220 | Mtr | 1,10,000 ₹1,29,800 Lowest | 1,14,400 ₹1,34,992 | 1,65,000 ₹1,94,700 |
| 1.04 | Termination of 1000 sq mm cable using necessary clamps, hardware, brass compression gland, lugs etc as required at site. | 4 | Job | 47,200 ₹55,696 Lowest | 50,000 ₹59,000 | 58,000 ₹68,440 |
| 1.05 | Supply of GI perforated cable tray with various size(width – 600 mm,50 mm – 2 mm), including bends, tees & necessary hardware as required at site. | 20 | Mtr | 13,600 ₹16,048 | 13,800 ₹16,284 | 10,000 ₹11,800 Lowest |
| 1.06 | Installation of cable tray with non welded joints and structures. Requirement of cable tray shall be decided as per cable size with necessary hardware like angle, nut bolts & fastner etc as required at site. | 1 | Job | 29,400 ₹34,692 | 29,600 ₹34,928 | 25,000 ₹29,500 Lowest |
| 1.07 | Connection between Main LT Panel to motor/starter with the 1000 sq. mm x 1 core cable & suitable thimbles, lugs & glands etc as required at site. | 4 | Jobs | 60,800 ₹71,744 | 55,200 ₹65,136 Lowest | 1,00,000 ₹1,18,000 |
| 1.08 | Testing and commissioning of cable from LT panel as per required parameter include following :
i. Continuity earth test
ii. Meggaring of all equipment for phase to phase, phase to neutral and phase to earth.
iii. Conducting all function test. | 1 | Job | 42,300 ₹49,914 | 44,000 ₹51,920 | 25,000 ₹29,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹22,500
Closing Date
17 Sept 2025, 3:00 pmClosed
Sh. Yogesh Lohchab
Wazirabad Water Works
Changing of LT Cable system with other allied works of set no -1 and 2 at 3rd Raw Water Pump House. (Re-invite)
2025_DJB_278035_7
NIT No. 08 (2025-26)
Open Tender
Miscellaneous Services
Item Rate
30 days
Wazirabad Water Works
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804
₹22,500
24 Sept 2025
11 Sept 2025
17 Sept 2025
11 Sept 2025
17 Sept 2025
11 Sept 2025
11 Sept 2025 - 17 Sept 2025
Dismantling of defective 1000 Sq mm single core cable from the main LT cable from the main LT panel after suitable checking live parts to ensure safety of the working persons & other items requiring change in the panel as required at site.
Supply of 1000 mm sq x 1 core aluminium armoured cable 1.1 kV grade. Make : Havells/Grandley/ Gloster.
Laying of 1000 sq mm sq cable using necessary clamps, hardware, brass compression glands, lugs etc as required at site
Termination of 1000 sq mm cable using necessary clamps, hardware, brass compression gland, lugs etc as required at site.
Supply of GI perforated cable tray with various size(width – 600 mm,50 mm – 2 mm), including bends, tees & necessary hardware as required at site.
Installation of cable tray with non welded joints and structures. Requirement of cable tray shall be decided as per cable size with necessary hardware like angle, nut bolts & fastner etc as required at site.
Connection between Main LT Panel to motor/starter with the 1000 sq. mm x 1 core cable & suitable thimbles, lugs & glands etc as required at site.
Testing and commissioning of cable from LT panel as per required parameter include following : i. Continuity earth test ii. Meggaring of all equipment for phase to phase, phase to neutral and phase to earth. iii. Conducting all function test.
SAI TRADING CORPORATION (BID ID -1620470)
RUDRA ALLIANCE (BID ID -1620490)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .