Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-Finance | ₹9.5 L | L1 | Accepted-Finance Lowest rate of tender |
| 2 | L2₹9.6 LRejected-Finance 5A GOBINDA SARKAR LANE KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | ₹9.6 L | L2 | Rejected-Finance Higher rate |
| 3 | L3₹9.6 LRejected-Finance | ₹9.6 L | L3 | Rejected-Finance Higher rate |
| 4 | L4₹9.6 LRejected-Finance | ₹9.6 L | L4 | Rejected-Finance Higher rate |
| 5 | L5₹9.7 LRejected-Finance 919 G MOTILAL GUPTA ROAD KOLKATA 700082 | KOLKATA | WEST BENGAL | 700082 | ₹9.7 L | L5 | Rejected-Finance Higher rate |
Tender Value
₹9.6 L
EMD Value
₹19,201
Closing Date
11 Mar 2026, 11:00 amClosed
Executive Engineer PWD KNHD
P16 INDIA EXCHANGE PLACE EXTENSION 2ND FLOORKIT BUILDING Kolkata 700 073
Annual Group maintenance of Building works to the old building G2 of W.B University of Health Science, Salt Lake sL-2
2026_WBPWD_1014662_2
WBPWD/EE/KNHD/NIT-56/25-26
Open Tender
Support/Maintenance Service
365 days
University of Health Science
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,201
Yes
9 Jun 2026
25 Feb 2026
13 Mar 2026
25 Feb 2026
11 Mar 2026
25 Feb 2026
Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary.(Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only).
Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any.[concrete plaster will be paid separately]
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian (ground floor)
1st floor
2nd floor
Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. 3rd floor level
Easing and oiling, cleaning collapsible gate and repairing to locking arrangements.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) Size not Iess than 600mmX 600 mm X 9.5 mm thick) ground floor
1st floor
2nd floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. WALLS Area of each tile above 0.09 Sq.m, Coloured decorative. ground floor
1st floor
2nd floor
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (ground floor )
1st floor
2nd floor
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
Supplying maruti lock (100mm)
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5 mm thick coloured / tinted / smoke glass.
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof:- With 0.5 mm thick sheet
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-Grid T-2430/1510)
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor ncluding removing rubbish within a ead of 75 m as directed.
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent: 4 water: 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement morter 20 mm thick plaster
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thick) Water Proof
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) one coat Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer): (Two coats) standard Quality
Supplying, fitting&fixing granite tiles 10 mm to 12 mm. thick incolumns,wall, facia etc.with 15 thick[avg]cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass/copper hooks including pointingin cement mortar (1:2) (1white cement : 2 marble dust) with admixture of pigment matching the stones hadesall complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Usingcement slurryat back sideof [email protected]/sq.m& white cement slurry for joint filling @ 1.8 kg/sq.m Area of each slab upto 0.2 Sq.m
Hydraulic door closer of approved quality as per I.S.I.standard fitted and fixed complete.Godrej Hydraulic door closer fitted and fixed complete.) Medium type
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fittedand fixed with cadmium plated screws. 300mm long x 10mm dia. Bolt
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete 300mm x 16mm dia. bolt.
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fittedand fixedwith cadmium plated screws 100 x 75 x 4.0mm.
Anodised aliminiumD-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fittedand fixed complete: 150 mm grip x 12 mm dia rod.
Door stopper (Anodised aluminium)
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and theentireframefitted with 37.5mm wide battens places both ways inorder tomake thedoor of solid core and internal lipping with Garjanor similar wood veneersusingphenol formaldehydeasglue etc.complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. 35 mm thick shutters (single leaf)
Supplying fitting & fixing in position 9 mm thick Heavy Duty Cement board - Type- A (High Pressure steam cured, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density > 1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 & ISO 8336, with fibre cement screws in partition excluding cost of supporting structure as per drawings and direction of Engineer-in-Charge complete. (Note: The Item -26 under Section - U (Page -247) can be used as supporting structure for internal partition ).
Supplying 'Godrej' mortice lock chromium plated with keys 4 levers including fitting & fixing complete.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.11 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_2492385.xls
BOQ • 0.40 MB
2911_NRe_6th5696FY011019_M3_OK.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid