Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | ₹36.7 L Quoted ₹37.3 L | L1 | Accepted-AOC LOWEST BID |
| 2 | L2₹38.0 L+₹62,364 (1.67%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | ₹38.0 L+₹62,364 (1.67%) | L2 | Rejected-Finance HIGHER BID |
| 3 | L3₹38.9 L+₹1.5 L (4.13%)Rejected-Finance | ₹38.9 L+₹1.5 L (4.13%) | L3 | Rejected-Finance HIGHER BID |
| 4 | L4₹40.5 L+₹3.1 L (8.43%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹40.5 L+₹3.1 L (8.43%) | L4 | Rejected-Finance HIGHER BID |
| 5 | L5₹43.5 L+₹6.1 L (16.4%)Rejected-Finance | ₹43.5 L+₹6.1 L (16.4%) | L5 | Rejected-Finance HIGHER BID |
| Sl No | Description | Qty | Unit | Abhishek Enterprises L4 | Ashok Electric and Electronics L5 | MONA GENERATOR SEVICES PVT. LTD. L6 | NAGEL ENTERPRISES L1 | Shree Saaram Engineers L3 | JYOT ENTERPRIES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed. | 550.8 | CUM | 180 ₹99,144 | 260 ₹1,43,208 | 196 ₹1,07,956.8 | 300 ₹1,65,240 | 130 ₹71,604 Lowest | 220 ₹1,21,176 |
| 2.00 | Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed. | 328.6 | CUM | 50 ₹16,430 | 90 ₹29,574 | 73 ₹23,987.8 | 40 ₹13,144 Lowest | 40 ₹13,144 Lowest | 40 ₹13,144 Lowest |
| 3.00 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed. | 222.2 | CUM | 40 ₹8,888 Lowest | 85 ₹18,887 | 45 ₹9,999 | 40 ₹8,888 Lowest | 50 ₹11,110 | 40 ₹8,888 Lowest |
| 4.00 | M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed.
Note: Punned thickness shall only be measured and paid | 165.2 | CUM | 950 ₹1,56,940 | 860 ₹1,42,072 | 977 ₹1,61,400.4 | 200 ₹33,040 Lowest | 550 ₹90,860 | 900 ₹1,48,680 |
| 5.00 | Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed. | 13,600 | EACH | 21 ₹2,85,600 | 17 ₹2,31,200 Lowest | 20 ₹2,72,000 | 21 ₹2,85,600 | 20 ₹2,72,000 | 24 ₹3,26,400 |
| 6.00 | S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, for cable protection complete all as speicifed and directed. | 36 | RM | 450 ₹16,200 | 390 ₹14,040 Lowest | 436 ₹15,696 | 450 ₹16,200 | 400 ₹14,400 | 390 ₹14,040 Lowest |
| 7.00 | Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 2 core 10 sqmm etc. complete all as specified and directed | 100 | RM | 150 ₹15,000 | 160 ₹16,000 | 150 ₹15,000 | 115 ₹11,500 Lowest | 121 ₹12,100 | 156 ₹15,600 |
| 8.00 | Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 10 sqmm etc. complete all as specified and directed | 320 | RM | 175 ₹56,000 | 190 ₹60,800 | 211 ₹67,520 | 150 ₹48,000 | 148 ₹47,360 Lowest | 221 ₹70,720 |
| 9.00 | Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 16 sqmm etc. complete all as specified and directed | 1,500 | RM | 235 ₹3,52,500 | 230 ₹3,45,000 | 226 ₹3,39,000 | 190 ₹2,85,000 Lowest | 191 ₹2,86,500 | 236 ₹3,54,000 |
| 10.00 | Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 25 sqmm etc. complete all as specified and directed | 150 | RM | 300 ₹45,000 | 280 ₹42,000 | 299 ₹44,850 | 240 ₹36,000 Lowest | 263 ₹39,450 | 310 ₹46,500 |
Tender Value
₹39.4 L
EMD Value
₹78,820
Closing Date
17 Feb 2026, 6:00 pmClosed
GE ARMY
BHUJ
REPAIR/REPLACEMENT TO CERTAIN LT PANELS, AND VARIOUS OTHER ITEMS AND CETAIN MISC E/M WORKS TO VARIOUS STREET LIGHT UNDER GE (A) BHUJ
2026_MES_750458_1
8419
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹78,820
18 Mar 2026
29 Jan 2026
19 Feb 2026
29 Jan 2026
17 Feb 2026
12 Feb 2026
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, for cable protection complete all as speicifed and directed.
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 2 core 10 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 10 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 16 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 4 core 25 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 3.5 core 35 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 3.5 core 50 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 3.5 core 70 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 3.5 core 95 sqmm etc. complete all as specified and directed
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls of size 3.5 core 240 sqmm etc. complete all as specified and directed
M&L for Disconnecting, taking out, removing old existing unserviceable LT underground cable of any size all as specfied and directed
Material and labour for bring the van mounted full automated underground cable fault locator machine at site for find out LT cable fault in underground completely all as specified and directed. Note: (a) Fault machine,cable & T&P required shall be arranged by the contractor. (b) Cable jointing kit for LT is measured separately
M&L for refreshing of incomming and all outgoing XLPE cable of any size including excavation for removing cable loop , refreshing of exsiting all cable by removing insulation ,including removing old damaged lugs and fixing of suitable size lugs, PVC conncetor,dressing of all cables . nuts ,bolts,washer to all incomming and outgoing MCCB , insulating all bare conductor with insulating cable of suitable colour all as sepcfiedc and directed. Note: 1. Lugs and insulation tap will be measured as separate item.
M&L for repair of LT panel doors using 75 mm SS hinges, SS latch, including welding & cutting work as per site requirement all as specified and directed.
M&L for spray painting of LT panel inside and outside surface, including surface prepration by scrubbing of existing paint, and applying two coat of synthtic enamel paint over one coat of red oxide, colour of paint & pattern as per exsiting all as specfied and directed.
Supply and fix in repiars the following items and disconnecting, taking out the old unserviceable one, including necessary replacemnet of lugs ,nuts,bolts lugs , cutting existing CRCA sheet of any size and capacity wherever reqd complete all as speicifed and directed.
MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA complete all as speicifed and directed.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA complete all as speicifed and directed.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 160 Amps 36 KA complete all as speicifed and directed.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 250 Amps 36 KA complete all as speicifed and directed.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 400 Amps 36 KA complete all as speicifed and directed.
M&L for removing shrub and creeper on electrical pole ,electrical panel ,at substation ,chain link fencing on hardstanding pcc all as specfied and directed.
supply and fix in repiar on load changeover 415V 250A with enclosure, disconncetion & taking down and reconnection with proper size of lugs all as specfied and directed.
Material and labour for cutting of existing road ,insert the required size pipe for drawn of cable etc and repair the same with PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for filling the disturbed road opening for cable crossing include levelling with road surface and smooth finishing complete all as specified and directed. ( for Road Cutting Repair)
Maintaning of LT over head lines by trimming the of tree branches tuching to the HT/LT over head conductors lines upto 03 mtr away from the live conductors surrounding area complete all as speicifed and directed.. Note :- cost of labours deemed to be including cutting the tree branches and depositing the tree branches away 50 Mtr away from the poles or as directed at sie complete.
Taking down & Supply and fixing cable junction box with new pole mounted polycarbonate cable junction box of size 255x205x112mm or next higher size for street light with IP-66 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system, cable gland, cable terminal for incoming and outgoing cable according to cable size including terminals for one incoming and one outgoing cables of size 16/25 sqmm 4 core, tapping of 3 Core 2.5/1.5sqmm from terminals, with one MCB SP 6 Amp 240V AC with mounting on DIN rail, pole clamp of flat iron, nut, bolt and washers complete all as specified and directed . Make : National/Sintex/Hansel
Supply and fix and heating of insulating PVC sleeve of size suitable for LT cable of szie 25 sqmm to 180sqmm as per colour code including refreshing end of cable on pole or LT panel all as specfied and directed.
Supply install testing,commissioning of CRI tested Copper earthing electrode of length 3 metres, 40mm dia and back fill compound of 50kgs ,and conductive gel to retain moisture should be filled layer wise and inter connceted by exothermic brazing & copper strip of size 32x6mm should be suppllied and fix upto testpoint protected by GI pipe of size 50mm dia up to test point including disconnection of old earth strip and fix to new chemical earthing, PCC earth pit of standared size as per SSR part-1 and submmision of earth results and painting of Date of test , value obtain at site and all specified and as directed.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to Galvanised iron earth strip 32x6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed. Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On testing after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Supply and fix PVC copper cables from bus bar to MCCB inside panal including nuts bolts washer ,drilling holes in to bus bar of following sizes completion all as specified and directed.
a)10 sqmm PVC single core
b)16 sqmm PVC single core
c) 25 sqmm PVC single core
Supply and fix 2 core aluminium service cale of size 4sqmm all as specfied and directed.
Supply and fix 2 core aluminium service cale of size 6sqmm all as specfied and directed.
Supply and fix 2 core aluminium service cale of size 10sqmm all as specfied and directed.
Supply and fix aluminium lugs of following size including insulation on lugs as per colour code complete all as speicifed and directed.
a) 16sqmm
b) 25sqmm
c) 35sqmm
d) 50sqmm
e) 70sqmm
f) 120sqmm
g) 150sqmm
i) 250sqmm
j) 300sqmm
M&L for cable jointing kit LT 1.1KV straight through joint 185sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 120sqmm ,heat shrinkable type with all accessories a completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 95 sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 70 sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 50sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 35sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
M&L for cable jointing kit LT 1.1KV straight through joint 25sqmm ,heat shrinkable type with all accessories completion all as specified and directed.
Supply and drawing through the pole for making connections to the light fittings, three core, PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor (FRLS) cable 3Cx1.5 sqmm complete all as specified and directed.
Supply and fixing PVC pipe 25/20 mm through FRP Junction to street light clamp on the pole including all connecting accessories to the pole complete all as specified and directed.
Supply and fixing PVC flexible pipe 25/40 mm for protection of cable etc complete all as specified and directed.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with system efficacy greater or equal to 120 lumen/watt, beam angle =120 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV and optics designed for Road lightning ,PF>0.95 and IEC safety class 1 protection complete all as directed. Make : Philips Cat Part No BRP331 LED 42 or any equivalent of Bajaj/Havells
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with system efficacy greater or equal to 120 lumen/watt, beam angle =120 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV and optics designed for Road lightning ,PF>0.95 and IEC safety class 1 protection complete all as directed. Make : Philips Cat Part No BRP333 LED 84 or any equivalent of Bajaj/Havells
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with system efficacy greater or equal to 120 lumen/watt, beam angle =120 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV and optics designed for Road lightning ,PF>0.95 and IEC safety class 1 protection complete all as directed. Make : Philips Cat Part No BRP334 LED 110 or any equivalent of Bajaj/Havells
Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with system efficacy greater or equal to 120 lumen/watt, beam angle =110 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV PF>0.95 and IEC safety class 1 protection complete with driver and lamp. Make : Philips Cat Part No BVP282 LED120CW FG SY5WB or any equivalent of Bajaj/Havells
Supply and fixing in replacement LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with system efficacy greater or equal to 120 lumen/watt, beam angle =110 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV PF>0.95 and IEC safety class 1 protection complete with driver and lamp. Make : Philips Cat Part No BVP283 LED240CW FG SY5WB or any equivalent of Bajaj/Havells
Supply and fixing in replacement 100 watt 230 volts AC High bay light with high efficiency having minimum 120 lumen/watt complete with drivers, suitable connection for hanging on ceiling with including connecting up with three core flexible copper conductor cable of suitable size complete all as speicifed and directed. Make: Philips/Crompton/Bajaj
M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 2.50 Sqmm for connection drawing through pole or GI brackets from junction box to light connector of street light fittings including heavy duty PVC conduit of size 20mm dia, lugs /thimbles according to size of cable complete all as directed.
Labour only for checking the serviceability of different spares / components / parts of security light fitting/street light any wattage/capacity of any description and in position or by taking down the fitting, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fitting and making the light fitting serviceable, connecting to electric supply and its testing on installation complete all as directed. NOTES : Contractor's quoted rates are deemed to be included the following : - (a) Removal of unserviceable / broken parts of fitting, fixing of new parts(driver) in replacement to make the fitting serviceable. New parts shall be measured and paid for separately as "supply only" against respective item of Sch ‘A’ and treated as one complaint. (b) Necessary T&P i.e. ladder, tools etc required for checking, making the light fitting in serviceable conditions including necessary screws, insulating tapes, internal wiring, gasket etc fixing in position and testing, of any description on poles / on walls / on pillars etc i.e. in any position. (c) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (d) when refreshing the cable, insulation tape should be done to avoid carbon.
Supply only LED driver for street light rating upto 45W complete all as specfied and directed
Supply only LED driver for street light rating from 45W upto 90W complete all as specfied and directed
Supply only LED driver for flood light rating from 200W complete all as specfied and directed
Supply only LED MCPCB (LED chip) upto 45W complete all as specfied and directed
Supply only LED MCPCB (LED chip) from 45 to 90W complete all as specfied and directed
Supply only LED MCPCB (LED chip) from 100W to 200W flood lightcomplete all as specfied and directed
Material and labour for Repairs to replacement of Unserviceable Street Lights Digital Timer switch single phase 230V Operated 50 hz frequency with inbuilt chargeble battery backup upto minimum 24 hrs complete all as specified and directed. Make : L & T GIC Make CRONO cat part No 67DDT0 or any equivalent Specifications of ISI Make as approved by the GE.
Material and labour for replacement of un serviceable 3 pole 415 Volts power contactors Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1,Current Rating up to 40 Amps for Street Light Timer switches complete all as specified and as directed. Make : L&T cat part No MNX 40 or any equivalent of Siemens/Schnider
Supply and fix 2 core aluminium service cale of size 4sqmm all as specfied and directed.
Supply and fixing in replacement old rusted street light bracket, clamps, nuts and bolt with new street light bracket made out of 25 mm dia medium grade GI pipe (length of pipe should not be less than 2 mtrs) , two set of clamp flat iron, nuts & bolts as required , bend to shape and fixing arrangement duly welded complete all as speicifed and directed.
Supply and fixing in replacement old unserveceable cable junction box size 250mm x 200mm x 100 mm with new pole mounted thermoplastic cable junction box for street light with IP-65 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed . Make: Sintex/National
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
LISTOFMAKE.pdf
Tender Documents • 0.20 MB
BOQ_840514.xls
BOQ • 0.38 MB
TENDER8419.pdf
Tender Documents • 0.54 MB
PS8419.pdf
Tender Documents • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .