| 1 | SITC of 80W LED Floodlight luminaire | SITC of 80W LED Canopy luminaire with powder coated pressure die-cast aluminium housing with Heat resistance clear toughened glass and silicon gasket fixed with SS screws. Lens should be mechanically fixed and fixing by glue is not acceptable with The potted driver used is specially designed to have built-in open or short circuit protections. The luminaire should have CRI more than 70, and CCT of 5700K and shall be compliant with IP65 classification with operating temperature of -10degC to +50degC. Luminaire shall be designed to emit at least 9600 nominal lumens with system efficacy of at least 120 lumen per watt. The luminaire shall be designed to ensure lumen depreciation L70 over 50000 burning hours as per LM 80 report. The luminaire should have fins on the back to ensure good heat dissipation and to prevent dirt from settling on the luminaire along with aiming angle scale. Driver should be fully potted BIS certified and shall have a power factor more than 0.95 and THD less than 10 percentage with a minimum inbuilt surge protection of internal 4kV and external 10kV and suitable for an operating voltage range of 140 to 280V AC. Driver should sustain upto 8 hours at 440 V AC.Driver should comply Driver safety requirements as per IS 15885 with BIS certification. Manufacturer should have in house NABL testing facility. LM 79 report from NABL accredited Lab shall be submit. The luminaire should comply with all the required IEC and IS standards. | 4 | Job | amrendraks | 60 |
| 2 | SITC of 50W RGBW Surface mounted Medium beam Square Projector | SITC of RGBW Surface mounted Medium beam Square Projector luminaires suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution with glass cover. Power consumption should be between 45W to 50W at steady state full intensity. Luminaire should be able to run on AC or DC Voltage. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral or separate non-integral power supply unit. The lumen maintenance L70 at 25 deg. C of the LED shall not be less than 70 percentage of the initial lumen after 50,000 burning hours. Ingress Protection should be IP66 or higher. Housing should be made of Diecast Aluminium with 3-4 mm thick safety glass. Impact resistance level should be suitable to site condition. Adequate heat sink with proper thermal management shall be provided. Operating Temperature - 10 Deg. C to +50 Deg. C, Operating Humidity - 10 to 90 percentage , Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE or LUMILED or OSRAM or NICHIA or reputed make shall be used for the light fittings. | 4 | Job | amrendraks | 60 |
| 3 | SITC of 20W RGBW Surface mounted Narrow beam Square Projector | SITC of RGBW Surface mounted Narrow beam Square Projector luminaires suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution with glass cover. Power consumption should be between 15W to 20W at steady state full intensity. Luminaire should be able to run on AC or DC Voltage. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral or separate non-integral power supply unit. The lumen maintenance L70 at 25 Deg. C of the LED shall not be lessthan 70 percentage of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of Diecast Aluminium with 3-4 mm thick safety glass. Impact resistance level should be suitable to site condition. Adequate heat sink with proper thermal management shall be provided. Operating Temperature- 10 Deg. C to + 50 Deg. C, Operating Humidity- 10 to 90 percentage, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE or LUMILED or OSRAM or NICHIA or reputed make shall be used for the light fittings. | 12 | Job | amrendraks | 60 |
| 4 | SITC of DMX Controller System | SITC of DMX Controller System with Standalone interfaces. Controller should deliver 2 x 512 DMX channels, the controller should have future upgradation provision up to 4 DMX universe Port. the controller should have new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management.). the controller should offer multiple possibilities to trigger your lighting scenes - time or date, input ports, TCP or UDP commands. Should have Intuitive backlit keyboard with 10 presets. PC DMX IN triggers-Yes, Standalone DMX IN triggers- External triggers- 10 buttons for direct access,2 buttons to change scene,+ 1 button to change zone. 16 dry contact trigger ports via 20-Pin IDC Socket. Internal calendar- Yes, Backup of the internal clock - Yes, 3weeks without power, Memory card- Yes microSD card, 32GB max, Input power voltage- 5 to 5.5V DC 0.6A with power adaopter working on AC power supply, via USB(USB power supply included), Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons - iPhone or iPad or Android remote and programming apps. Temperature- 0 to +50 Deg. C , DMX Compatibility- 8 and 16 bit DMX fixtures, System Compatibility- Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X. | 1 | Job | amrendraks | 60 |
| 5 | SITC of 4 port Splitter cum Booster | Supply, installation, testing and commissioning of DMX Splitter cum Booster, Input Power- 100 to 240 VAC, auto-ranging, 50 or 60 Hz.,Housing rugged alluminium, Operation Temperature -17 Deg. C to +55 Deg. C (0 Deg. F to 131 Deg. F) , 5 or 6 output ports with 3 or 5-pin terminal sockets , each port should be optically isolated, Protection Rating IP20 including connection complete as required. | 1 | Job | amrendraks | 60 |
| 6 | Supplying and fixing 8 way DD SPN MCB DB | Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface or recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB or RCCB or Isolator) | 1 | Each | amrendraks | 60 |
| 7 | Supply and fixing of SP MCB | Supplying and fixing 5 amps to 32 amps rating, 240 volts, 10 kA, C - curve,miniature circuit breaker suitable for inductive load of SP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 6 | Each | amrendraks | 60 |
| 8 | Supply and fixing of DP MCB | Supplying and fixing 32 amps rating, 240 volts, 10 kA, C - curve,miniature circuit breaker suitable for inductive load of DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | Each | amrendraks | 60 |
| 9 | | Wiring for Group-C light point or fan point or exhaust fan point or call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface or recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 10 | Point | amrendraks | 60 |