Loading…
Loading…
Tender Value
₹84,486
EMD Value
₹2,112
Closing Date
10 Jun 2026, 3:00 pm5d left
Assistant Executive Engineer
O/o Office of the Assistant Executive Engineer,Electrical Sub Division Pathanamthitta, (For and on behalf of Governor of Kerala)-689645
GENERAL-Electrical Maintenance work in Connection with ceiling work at AEO Office Thiruvalla-General Electrical Work
2026_PWD_853621_1
PWD/BLDG/TR/6488/2026
Open Tender
Electrical Works
60 days
THIRUVALLA
Please refer Tender documents.
12 documents required · 12 mandatory
₹555
₹2,112
1 Jun 2026
1 Jun 2026
15 Jun 2026
1 Jun 2026
10 Jun 2026
1 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Electrical Maintenance Work | ||||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,689.22 | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 1.54.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | - | point | 1,259.99 | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | OD11792/2026-2027:Supply, Conveyance and fixing charges for 1800 lumen round/ square(1X1) recessed fitting made of die cast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea with all accessories in the existing hole of false ceiling, giving connections with the existing wire etc. as required. | - | each | 2,585.29 | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | OD11787/2026-2027:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% with remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: | - | each | 3,142.89 | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. | - | each | 205.4 | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | 424.29 | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. | - | each | 114.24 | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | - | metre | 109.53 | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | - | metre | 237.1 | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1442638.xls
BOQ • 0.33 MB
viewsbd.pdf
Tender Documents • 2.07 MB
Download all tender documents and submit your bid