Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAdmitted-Finance | ₹3.2 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 L+₹1.8 L (54.3%)Admitted-Finance | ₹5.0 L+₹1.8 L (54.3%) | L2 | Admitted-Finance |
| 3 | L3₹6.7 L+₹3.4 L (106.3%)Admitted-Finance | ₹6.7 L+₹3.4 L (106.3%) | L3 | Admitted-Finance |
| 4 | L4₹7.3 L+₹4.1 L (126.7%)Admitted-Finance 102 JASMINE PLOT N0 15 SECTOR 44 SEAWOODS WEST 400706 THANE MAHARASHTRA 400706 | THANE | MAHARASHTRA | 400706 | ₹7.3 L+₹4.1 L (126.7%) | L4 | Admitted-Finance |
| 5 | L5₹7.3 L+₹4.1 L (126.8%)Admitted-Finance | ₹7.3 L+₹4.1 L (126.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SRI SRINIVASA ENGINEERING WORKS L3 | ULTRA MARINE L7 | SHRI GURUDATTA ENGINEERING WORKS L5 | MY ENTERPRISES L6 | RAO ELECTRICAL ENGINEERIONG WORKS L2 | NASS Engineering Services Pvt Ltd L4 | RAVI MUTHUSAMY L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00BELOW MENTIONED LT COOLERS & HT COOLERS NEED TO BE CHEMICALY CLEANED AND PRESSURE TESTED. OPERATIONAL TRIALS TO BE SHOWN TO SHIP STAFF. | ||||||||||
| 1.10 | Central F.W. Cooler GXD-51N
Plate type Exchanger
Titanium Plate
F.W. Flow : 120 m3/h
S.W. Flow : 156 m3/h
Heat Dissipation : 3 308 kW Surface Area : 97.35 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket As required. (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 2 | NOS | 82,000 ₹2,08,000 | 4,00,000 ₹8,00,000 | 1,07,000 ₹2,16,000 | 1,55,000 ₹3,50,000 | 49,000 ₹1,22,000 | 83,000 ₹1,90,000 | 12,810 ₹85,400 Lowest |
| 1.20 | Aux. Sys. FWD F.W.
Cooler
GCP-51N
Plate type Exchanger
Titanium Plate
F.W. Flow : 120 m3/h
S.W. Flow : 156 m3/h
Heat Dissipation : 561 kW
Surface Area : 17.28 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket (Ship Supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 1 | NOS | 61,000 ₹77,000 | 4,00,000 ₹4,00,000 | 98,700 ₹99,700 | 1,20,000 ₹1,40,000 | 49,000 ₹61,000 | 83,000 ₹95,000 | 12,810 ₹42,700 Lowest |
| 1.30 | Aux. Sys. AFT F.W. Cooler
GX-60P
Plate type Exchanger Titanium Plate
F.W. Flow : 240 m3/h
S.W. Flow : 310 m3/h
Heat Dissipation : 2 214 kW
Surface Area : 63.28 m3 Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket as required (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 2 | NOS | 77,000 ₹1,94,000 | 6,50,000 ₹13,00,000 | 97,700 ₹1,97,400 | 1,40,000 ₹3,20,000 | 89,000 ₹2,18,000 | 1,60,000 ₹3,50,000 | 16,470 ₹1,09,800 Lowest |
| 1.40 | Heat Recovery Exchanger GX-42P
Plate type Exchanger SUS Plate
F.W. Flow : 40 m3/h
H.W. Flow : 115 m3/h
Heat Dissipation : 772 kW
Surface Area : 33.0 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket As required. (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines 10 NO PLATES TO BE
ADDED IN HT COOLER NO 1 E-741 | 2 | NOS | 74,000 ₹1,88,000 | 4,00,000 ₹8,00,000 | 1,08,000 ₹2,20,000 | 1,20,000 ₹2,80,000 | 40,000 ₹98,000 | 42,000 ₹98,000 | 12,810 ₹85,400 Lowest |
Tender Value
Refer Docs
Closing Date
4 Sept 2026, 3:00 pmClosed
M (SRC-OS)
Ph.No. 9493792254
OVERHAULING OF VARIOUS COOLERS ON ORV SAMUDRA RATNAKAR
2026_HSL_100019_1
SR COMPLEX/PRODUCTION/OUT SOURCE REQUISITION/2026/355
Open Tender
Miscellaneous Services
Service
30 days
HSL, VISAKHAPATNAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
9 Sept 2026
1 Sept 2026
4 Sept 2026
1 Sept 2026
4 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1BELOW MENTIONED LT COOLERS & HT COOLERS NEED TO BE CHEMICALY CLEANED AND PRESSURE TESTED. OPERATIONAL TRIALS TO BE SHOWN TO SHIP STAFF. | |||||
| 1.1 | Central F.W. Cooler GXD-51N
Plate type Exchanger
Titanium Plate
F.W. Flow : 120 m3/h
S.W. Flow : 156 m3/h
Heat Dissipation : 3 308 kW Surface Area : 97.35 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket As required. (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 2 | NOS | - | - |
| 1.2 | Aux. Sys. FWD F.W.
Cooler
GCP-51N
Plate type Exchanger
Titanium Plate
F.W. Flow : 120 m3/h
S.W. Flow : 156 m3/h
Heat Dissipation : 561 kW
Surface Area : 17.28 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket (Ship Supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 1 | NOS | - | - |
| 1.3 | Aux. Sys. AFT F.W. Cooler
GX-60P
Plate type Exchanger Titanium Plate
F.W. Flow : 240 m3/h
S.W. Flow : 310 m3/h
Heat Dissipation : 2 214 kW
Surface Area : 63.28 m3 Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket as required (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines | 2 | NOS | - | - |
| 1.4 | Heat Recovery Exchanger GX-42P
Plate type Exchanger SUS Plate
F.W. Flow : 40 m3/h
H.W. Flow : 115 m3/h
Heat Dissipation : 772 kW
Surface Area : 33.0 m3
Scope of the work: Work involves
- Chemically Clean the cooler
- Renew the gasket As required. (ship supply)
- Pressure test the cooler
- Assemble the cooler and pipe lines 10 NO PLATES TO BE
ADDED IN HT COOLER NO 1 E-741 | 2 | NOS | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
CQ355.pdf
Tender Documents • 0.82 MB
TBID355.pdf
Tender Documents • 0.36 MB
BOQ_109588.xls
BOQ • 0.28 MB
URGENT.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .