MISCELLANEOUS ELECTRICAL WORKS IN ENERGY DEPARTMENT AT TNPL UNIT - II, TRICHY.
2026_TNPL_648441_1
TNPL/TOS/U2/ 252623004048
Open Tender
Electrical related work
365 days
TNPL UNIT II, MONDIPATTI
REFER PRE-QUALIFICATION CRITERIA
5 documents required · 5 mandatory
₹0
₹17,600
7 Mar 2026
29 Jan 2026
24 Feb 2026
29 Jan 2026
23 Feb 2026
29 Jan 2026
8337500379 Street Light: Dismantling/fixing of 75W / 150W 250W / 400W light fittings with control gear at elevations upto 30 Mtr.
8337500375 Earthing Systems: Renovation of earth pit - Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures, etc.
8337500376 Street Light: Installation of street light poles with a pole pit of 0.75 x 0.75 x 1.0M, erection of pole, concreting with 1:3:6 mix, cutting and bending of 50mm dia GI pipes for loop in / loop out in marshalling box, fixing and commission
8337500377 Street Light : Dismantling of street light poles.
8337500373 Surface wiring (Reaper or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit - For additional runs (more than one cable) in the same PVC Pipe
8337500380 Street Light : Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Mtr.
8337500381 Post top lantern/75W street light fitting: Installation of above luminaire on MS/GI post with a pole pit of 0.5 x 0.5 x 0.5 Mtr. Concreting with 1:3:6 mix, installation of marshalling box with loop in and loop out cabling, Cement
8337500384 Removal of XLPE insulated steel wire armoured aluminium conductor cable and wind the removed cable in drum / or as coil and shifting it to cable yard or other location as instructed by Engineers - 11 KV, 3 Core x 300 sq.mm Cable & above
8337500383 Excavation upto a depth of 1 mtr for laying the above cable sizes and for communication cables wherever necessary 2" sand cushioning and 3 side brick laying, refilling trench including cost of sand, brick etc.
8337500387 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire-Single/Twin tube light fitting
8337500388 Wiring in Industrial area: Wiring of armoured/power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - Fan with regulator / exhaust fan
8337500389 Wiring in Industrial area:Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire-Mercury vapour/sodium vapour lamp
8337500390 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board &fitting for the following along with earth wire - Electrical appliances upto 1.5KW
8337500391 House Wiring: Concealed wiring: Wiring in concealed PVC conduit of appropriate size between Main switch board and sub main switch boards to individual light/fan/power socket etc., using 7/20 or 3/20 PVC wire along with earth wire.
8337500392 House Wiring: Concealed wiring: Telephone wire in concealed PVC conduit - For single run (One Cable)
8337500393 House Wiring: Concealed wiring: Telephone wire in concealed PVC conduit - For additional runs (more than one cable) in the same PVC Pipe
8337500397 Fixing of pull chord switch (Fabrication, fixing angles, welding & fixing the switch)
8337500398 Fixing of pull chord rope hook (Fabrication of hooks & welding)
8337500400 Termination of LT cable / straight through joint after laying upto 2.5 sq.mm
8337500402 Cable laying and Termination work: Laying of L.T. power and control cables including charges for laying, dressing and clamping of cables - in racks, trays, in concrete shafts/underground excluding excavation and back filling upto 2.5 sq mm
8337500406 Wiring in Industrial area: Wiring of armoured/ power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - Single phase power socket
8337500407 Wiring in Industrial area: Wiring of armoured /power cable in conduit from switch board to individual light/fan etc including installation of switch board and fitting for the following along with earth wire - 3 phase power socket
8337500412 Cleaning of slots and preparing stator for rewinding - Upto 10KW
8337500418 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be in the scope of TNPL). Use of thinner for any exigency - shall not exceed 3% upto 10 KW
8337500419 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be scope of TNPL). Use of thinner for any exigency - shall not exceed 3% abv 10 Kw&upto 30 KW
8337500420 Painting of Motors - cleaning the surface, applying one coat of redoxide paint followed by 2 coats of smoke grey paint (supply of paint shall be scope of TNPL). Use of thinner for any exigency - shall not exceed 3% abv 30 Kw&upto 75 KW
8337500421 Excavation upto a depth of 600mm for laying the above cables sizes, 2" sand cushioning and 3 side brick laying refilling trench including cost of sand, brick etc.
8337500422 Excavation and back filling of cable trench upto a depth of 600mm including removal of old sand and bricks, relaying the same or providing inverted V shaped concrete coverings supplied by TNPL wherever applicable.
8337500423 Removing of the following cable sizes from racks/ trays in concrete trenches/overhead trays/ vertical shafts/undergrounds - upto 2.5 sq.mm
8337500427 Installation of earth pit including supply of charcoal and clay and brick chamber and laying and connection of earth pit to MSB - Excavation depth - 1.75 Mtr.
8337500429 Cutting of blacktop / concrete road and excavation upto a depth of 1000mm for laying pipes for cable crossing and refilling trench exclusing repair of blacktop / concrete
8337500431 Cable Trays, Supports, Frames and Misc. Steel Fabrication Works: Cable removal/fixing/ replacement of push button stations and/or canopy for the same.
8337500432 Surface wiring (Reaper or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit - For single run (One Cable)
8337500433 Earthing Systems: Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures,- Earthing using 50x6 GI/copper
8337500434 Earthing Systems: Installation of equipment grounding system for indoor and outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators etc and trays and grounding of structures,- Earthing using 25x3 GI/copper
8337500440 Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Metre
8337500442 Excavation upto a depth of 450mm and laying of Co-axial Cable in PVC pipe and refilling the trench without sand and brick
8337500443 Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays including dressing of cables - 11 KV, 3 core x 300 sq.mm cable & above
8337500430 Cable Trays, Supports, Frames and Misc. Steel Fabrication Works:Fabrication and erection of MS cable trays, supports, frame and Misc.Steel fabrication work including one anti-rust coat of primer ,two finished coats of approved enaml paint
8337500745 LAYING OF CABLE SIZE ABOVE 2.5 & UP TO 16 SQ MM
8337500746 LAYING OF CABLE SIZE 35 SQ MM
8337500747 LAYING OF CABLE SIZE 70 SQ MM
8337500748 LAYING OF CABLE SIZE ABOVE 70 & UP TO 185 SQ MM
8337500749 LAYING OF CABLE SIZE 240 SQ MM
8337500750 LAYING OF CABLE SIZE 300 SQ MM
8337500739 REMOVING OF CABLE SIZEABOVE 2.5 & UP TO 16 SQ MM
8337500740 REMOVING OF CABLE SIZE 35 SQ MM
8337500741 REMOVING OF CABLE SIZE 70 SQ MM
8337500742 REMOVING OF CABLE SIZE ABOVE 70 & UP TO 185 SQ MM
8337500743 REMOVING OF CABLE SIZE 240 SQ MM
8337500744 REMOVING OF CABLE SIZE 300 SQ MM
8337500752 Cable termination 2.5 sq mm & up to 16 sq mm
8337500753 Cable termination of 35 sq mm
8337500754 Cable termination of 70 sq mm
8337500755 Cable termination above70 sq mm & up to 185 sq mm
8337500756 Cable termination of 240 sq mm
8337500757 Cable termination of 300 sq mm
8337500720 CABLE TRENCH CLEANING
8337500721 Removing of Electrical scrap
8337500011 Helper - TNPL Unit II
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tendernotice_2.pdf
PDF • 0.55 MB
Tendernotice_3.pdf
PDF • 0.53 MB
Tendernotice_4.pdf
PDF • 0.28 MB
BOQ_777420.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid