| 1 | L1₹1.1 CrAdmitted-Finance NA | NA | NA | 121004 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹1.9 L (1.78%)Admitted-Finance 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | ₹1.1 Cr+₹1.9 L (1.78%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S DEEPAK SEMWAL L1 | R. S. ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil. | 177.89 | cum | - | - |
| 2.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). | 137.79 | cum | - | - |
| 3.00 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 4.14 | cum | - | - |
| 4.00 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand) | 59.23 | cum | - | - |
| 5.00 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand | 1.51 | cum | - | - |
| 6.00 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) | 111.51 | cum | - | - |
| 7.00 | Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) | 29.09 | cum | - | - |
| 8.00 | Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) | 52.59 | cum | - | - |
| 9.00 | Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete. | 24 | sq.m | - | - |
| 10.00 | Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. | 253.8 | sq.m | - | - |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
17 Jun 2020, 11:30 amClosed
S.E R.W.D Circle Pauri
Superintending Engineer Rural Works Department Circle Pauri Near Agency Chowk Pauri Garhwal
MAINTINANCE WORK OF SH.SHANAKARACHARYA MADHAVASHRAM HOSPITAL koteshwar at RUDRAPRAYAG
2020_RES_24033_4
40/R.W.D/T.I-02/2020-21
Open Tender
Civil Works - Buildings
Item Wise
365 days
Rudraprayag
Technical Qualification as per NIT
3 documents required · 3 mandatory
₹4,720
Executive Engineer Rural Works Department
₹2.2 L
22 Jun 2020
2 Jun 2020
17 Jun 2020
2 Jun 2020
17 Jun 2020
2 Jun 2020
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. T M T Fe 500 or more
Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together bymechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge.Profile B
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thickcement mortar 1:3 (1 Cement : 3 fine sand).
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing ISI marked oxidised M.S.sliding door bolts250x16mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodisedTwin rubber stopper
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes.
Providing & fixing fly proff wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 m and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Providing&laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface prepration, first layer of slurry of cement@ o.488kg/sqm mixed with waterproofing compound &.0.253kg/sqm (b) laying second layer of fiber glass cloth when the first layer is still green. overlaps of joints of fiber glass cloth should not be less than 10 cm.(c)third layer of 1.5mm thickness consisting of slurru of [email protected]/sqm mixed with waterproofing [email protected]/sqm and course [email protected]/sqm thish will be allowed to air cure for 4 huors followed by wter curring for 48 hours. the entire treatment will be taken up to 30cm on parapit wall and tucked into groove in parapit all around(d) fourth &final layer of brick tiling with cement morter (which will be paid seprately .for purpose of measurement the entire treated surface will be measured.
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Providing and applying white cement based putty of average thickness 1 mm of approvd brand and manufacture over plastered surface to prepare the surface even and smooth complete
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including finishing the topsmooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with commonburnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia 4mm.
Demolising brickwork manually/ by mechanical means including stacking servicible material and dispoal of unserviceble material within 50 m lead as per direction of Engineer -in -charge
Providing and fixing aluminium work for doors, windows, ventilators and partitionsFor fixed portion.Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitionsFor shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12mm thick prelaminated particle board flat pressed threePrelaminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters andWith float glass panes of 5.50 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand andWith stainless steel cover plate
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thickAnodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100mm with SSAnodized (AC 15 ) aluminium
Excavation in foundation for retaining & breast walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWD Uttarakhand specifications)
Random Rubble Masonary laid dry in breast wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C. grade M 20 Nominal mix 1:2:4 (Hand mixed)
Providing and Laying of Interlocking Concrete Block Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504.
R. S. ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.94 MB
BOQ_28627.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .