| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC 37 SAMARTH SOCIETY MEMNAGAR LAKE MEMNAGAR AHMEDABAD GUJARAT 380013 | AHMADABAD | GUJARAT | 380013 | L1 | Accepted-AOC Being L-1 | |
| 2 | L2₹15.9 L+₹52,484 (3.42%)Rejected-Finance 304 VELENTINE TOWER FILM CITY ROAD MALAD E MUMBAI 400097 | MUMBAI | MUMBAI | MAHARASHTRA | 400097 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.6 L+₹1.2 L (8.05%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹16.8 L+₹1.4 L (9.30%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹17.0 L+₹1.6 L (10.6%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L5 | Rejected-Finance Being L5 |
Tender Value
₹19.4 L
EMD Value
₹38,750
Closing Date
2 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr.Manager(E-E)
5th Floor, Operational Building, Parsiwada , Ville parle (E) , Mumbai-400099
As per BOQ
2020_AAI_58386_1
AAI/ENG/WR/SM/KAN/NIT-02/20-21
Open Tender
Electrical Works
Item Rate
90 days
Kandla Airport
As per Tender Notice
2 documents required · 2 mandatory
₹1,120
Yes
Airports Authority of India
₹38,750
Yes
23 Mar 2021
20 Oct 2020
4 Nov 2020
21 Oct 2020
2 Nov 2020
21 Oct 2020
21 Oct 2020 - 29 Oct 2020
90 days
Amount
Supply of heavy duty XLPE insulated PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098, Part I 1988 with upto date amendments of following size complete as required.
3.5 core 240 sq. mm
3.5 core 185 sq. mm
3.5 core 25 sq. mm
4 core 16 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required and making the ground surface same as before the execution of work.
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required and making the ground surface same as before the execution of work.
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required and making the surface same as before the execution of work.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm size in the existing masonry open duct as required and making the surface same as before the execution of work.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 x 3 mm MS flat clamp) size on wall surface as required and making the surface same as before the execution of work.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 x 3 mm MS flat clamp) size on cable tray as required and making the surface same as before the execution of work.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe of grade PN-04 , PE-63 along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
50 mm dia
100 mm dia
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
3.5 X 25 sq. mm (28mm)
3.5 X 185 sq. mm (57mm)
3.5 X 240 sq. mm (62mm)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 X 25 sq. mm
3.5 X 185 sq. mm
Design, Manufacture, Supply, Installation, Testing & Commissioning of totally enclosed, free standing, dust free, damp and vermin proof and water proof, Double door outdoor type IP 65 feeder pillar fabricated out of 2 mm thick CRCA sheet duly powder coated and including supply & fixing the following items and interconnection wiring with suitable size wires/cables and also including all civil work like excavation, PCC, Brick work etc. complete as per actual site requirement and specifications: (Please refer tender documents for details)
Supply and fixing of IP 65 loop in loop out box for street light poles (Hensel make, Model No-KM9250) of following sizes, including suitable connector and DIN rail for mounting of MCBs/connectors, making interconnections as required i/c suitable clamp for fixing.(Dimension-200mm x 160mm x 98mm)
Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required.
SKYLINE ENGINEERS
Techno Electricals
jaydeep agency corporation
Awasthi Electric Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .