Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹15.8 L+₹95,870.75 (6.45%)Rejected-Finance MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
25 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
PROVN OF SUPPORT INFRASTRUCTURE FOR ALTEK SIMULATOR UNDER PROJECT SUDARSHAN AT AF STN BHUJ
2023_MES_579563_2
8643/V/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER AND PS
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BHUJ
₹29,000
Yes
15 Apr 2023
6 Mar 2023
27 Mar 2023
6 Mar 2023
25 Mar 2023
13 Mar 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material & labour for 25 mm thick plain cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub base of floors etc complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for vitrified ceramic dark shade 10 mm thick (sqaure/rectangular) area of each tiles n.exc. 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match existing tiles and including 15 mm thick screed bed or bedding layer of mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
All as per item No 4.0 but in vertical surface such as dado,skirting and riser including rendering10 mm thick in CM 1:4 etc complete all as specified and directed by Engineer-in-Charge.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water remove Dust, debries/ rubbish etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of chalk whitening complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing old plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of chalk whitening complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm eachcomplete all as specified and directed by Engineer-in-Charge
Supply & fix anodised power coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix anodised power coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge
Material & labour for false ceiling of perforated particle board/tiles 60X60 cm in size and 12mm thick fixed with nails to timber frame work or with staples on snap grid fixed with screws in wall/ceiling, grid made of aluminium/G.I./M.S. complete all as specified and directed by Engineer-in-Charge.
Material & labour for aluminium window with double side hung shutter for glazing and gauging and frame with one or more rebates made out of JINDAL/ INDAL anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle and anodised aluminum fittings such as stay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) complete all as specified and directed by Engineer-in-Charge.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under above item shall be measured and paid separately
Supply only aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mm made out of standard aluminium moulded section of size 6mm x 7mm complete all as specified and directed by Engineer-in-Charge
Material & labour for 9 mm thick veneered particle board, solid core, exterior grade with decorative face veneers both face complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with and pressed steel terminal box powder coated of suitable size 3 mm thick backlite white/colour sheet top cover ISI marked with brass screws and cup washers for housing switches, socket, fan regulator etc complete all as specified and directed by Engineer-in-Charge for :-
One Fan point/exhaust fan controlled by one, one way switch single pole.
All as per item No 18 here-in-before but with 4.0 Sqmm Copper conductor cable for one 3 pin, 16 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge.
Supply & fix in recessed mounting LED 2x2 luminaire with white acrylic flat light dissipater with LED light source of 34/36 Watt of size 2’x2’(Feet) square shape suitable for False/POP ceiling including cutting the existing POP/false ceiling and fixing complete all as specified and as directed by Eng-in-Charge.
Material & labour for sub main wiring with two runs (two runs measured as one run) of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories to wall/ceiling with proper saddles and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and one run of conduit will be measured & paid as one unit)
Supply & fix modular switch 1 way 6A 1 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular socket 6A 5 pin 2 in 1 combined 2 module 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular socket 6/16A twin type 2 module 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular switch 16 Amp flush type 1 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of 3 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular white cover plate with frame of 4 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular white cover plate with frame of 6 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular surface mounting plastic box of 3 moduler ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular surface mounting plastic box of 4 moduler ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular surface mounting plastic box of 6 moduler ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix sheet metal enclosure double door type (CRCA) dust and vermin proof for DBs IP-43 protection class IP-43, 240 volts fixed on wall complete and making all connections complete all as specified and directed by Engineer-in-Charge for the following capacities-:
MCB DB SPN 12 way 240 volts with 200 Amps busbar
MCB DB SPN 8 way 240 volts with 200 Amps busbar
Supply & fix in replacement of isolators, MCBs, etc. In distribution board complete all as specified and directed by Engineer-in-Charge of the following rating and capacities-:
MCB SPN 240 volts 100 Amps Capacity, 10 KA
MCB SPN 240 volts 63 Amps Capacity, 10 KA
MCB SPN 240 volts 40/32 Amps Capacity, 10 KA
Supply & fix CEE 7/4 schuko socket enclosure 16 Amps, 240 volt with MCB DP 20 Amps complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing complete with copper earth plate electrode 60 cm x60 cm x 3.15 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper earth strip 20X3mm by means of nut, bolts, check nuts and washers of copper/ bronze as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour complete all as specified and directed by Engineer-in-Charge of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix copper strip 20 x 3.15 mm with saddles and fixing brazing etc for jointing etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for chemical earthing complete with Copper earth plate electrode (98 percent conductivity when annealed) of size 90cmx60cm x 5 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including Copper strip(98 percent conductivity when annealed) 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore GI pipe medium grade water pipe, wire mesh and lugs, test point etc including 150 mm of Magnesium sulphate above the top layer of salt and spreading evenly all round the plate and filling remaining with vegetable soil upto PCC chamber bottom and testing c complete all as specified and directed by Engineer-in-Charge. Note: On testing after completion, if the earth resistance less than desired is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Supply, install & testing air cooled split unit air conditioner 100% copper condenser & copper evaporator electric driven single phase of capacity of 2.0 TR indoor & outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating (as per 2019 BEE rating) including MS stand for oudoor unit, suction and delivery line copper material of suitable length as per site requirement complete including flexible copper cable 3 core 2.5 sqmm appx 2 M PVC drain pipe 20 mm dia approx 5.5 RM of including making holes to existing wall to draw cable and pipes to connect the indoor unit to the out door unit including provision of extra copper tubing/hoses etc and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
Supply & fix voltage stabilizer for automatic operation wall mounted single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stablized at 230 V with low and high cutoff facility including under and over current protection with accurancy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply & fix air cooled single phase isolation transformer 5 KVA, 240 V input voltage 240 V + 2.5% output voltage 240 V + 2.5% complete all as specified and directed by Engineer-in-Charge.
Radhe Krishn Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .