Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.2 L+₹2.0 L (21.7%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | L2 | Rejected-AOC L2 |
Tender Value
₹10.6 L
EMD Value
₹21,300
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
REPAIR MAINT TO UPKEEP EM INSTALLATION AT NARENDRA NAGAR, REPAIR REPLACEMENT OF LUMINARIES DISTRIBUTION BOARDS AND OTHER EM ALLIED WORKS AT RUDRAPRAYAG AND NARENDRA NAGAR AND REPAIR MAINT AND SERVICING OF SUMMER APPLIANCES AT NARENDRA NAGAR
2023_MES_631988_1
8778/E8
Open Tender
Civil Works
Item Rate
180 days
Narendra Nagar and Rudraprayag
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹21,300
Yes
2 Apr 2024
9 Dec 2023
18 Jan 2024
9 Dec 2023
11 Jan 2024
23 Dec 2023
Amount
Taking down Cement Plaster of any description on Brick or Stone walls or Concrete Surfaces including Racking out Joints, hacking for Key, scrubbing down with Water, etc. complete removal of debris outside MD land.
Dismantling mild steel work of any description from any position and height as directed and specified.
Demolition of brickwork built in cement mortar or cement lime mortar including all quoins arches pillars etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.
M& L for rendering in cement mortar (1:4), 15 mm thick finished even and smooth without using extra cement complete all as specified
M&L for plastering 15mm thick in CM 1:6 on internal face of wall ,finished even and smooth without using extra cement complete all as specified and directed complete.
M&L for brick work with modular size kiln well burnt bricks sub-class 'B', straight or curved on plan not exc 6m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coat of cement base paint complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels n exc 3 mtr long and joints shall be filled with the mixture of bitumen and sand in (1:3) by weight complete all as specified and directed.
M&L for old Plastered Surfaces and applying two Coats of cement base paint on Walls complete all as specified and as directed.
M&L for Preparation of Old decorated surface and applying one coat of white wash on Ceiling complete all as specified and as directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide primer over new untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described etc complete.
M&L for Preparation of old surface of wall and applying two coats of distemper oil bound over chalk whiting priming coat complete all as specified and as directed.
M & L for 100 mm thick cement concrete 1:4:8, type D2, with using 40 mm graded stone aggregate as in sub base to floors etc as specified and directed.
M & L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick as in floor, coping, finish the surfaces even and smooth with using extra cement complete as specified and directed.
M & L for Chequered cement concrete tiles 20Cm x 20 Cm x 20mm thick over and including 15mm thick screed bed in CM 1:6, set, jointed with grey cement and pigments and pointed in neat cement slurry in floors complete as directed and specified.
M & L for Running welding in repairs thickness of metal to be welded n.exc 6mm complete
Taking down of steel gates/doors exceeding 2 Sqm each and re-fixing in the same opening after necessary repair complete all as specified and directed.
S & F in repair Mild steel work as in Hooks and Pintle hinges for steel gates including necessary welding, cutting holes in wall, making good with PCC 1:2:4 type B1 and two coats of painting & wall finish to match with the existing complete all as specified and directed.
Supply, fabrication and fixing in repair (partial repair work) mild steel framed work as in gates,grills,grating of drain, etc including MS plain black sheet, hand-made sliding bolts, etc complete with a coat of red oxide primer all as specified and directed. (The MS section & thickness of plain sheet shall be matched with existing).
S&F Mild Steel work with hollow MS tubular section square or rectangular section as rafter/purlin including necessary welding bolting complete with using ERW or induction butt welded tubes confirming to relevant I.S. Fe 410 -W (Gde?E- 250) quality?A complete all as specified and directed
M & L for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws as specified
Providing precast cement concrete louvers and jallies, 35mm thick type B0 1:2:4 ( 12.5mm graded aggregate) set in cement mortar (1:4)(mea-sured solid), including all mouldings but excluding frame
S&F Reinforced concrete pipes 300 mm bore class NP2, laid and jointed complete with collars
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
M&L for point wiring in replacement in PVC conduit (concealed) all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, flexible pipes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels including taking out old unsv wiring all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 27 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 27 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 27 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way incl taking out old unsv switch all as specified & directed.
S&F in replacement switch piano flush type 15/16 Amps single pole one way incl taking out old unsv switch all as specified & directed.
M&L in replacement socket out let 5 pin 5/6 Amps incl taking out old unsv socket all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps incl taking out old unsv socket all as specified and directed.
S&F in replacement ceiling rose 3 terminals 65x25 mm dia poly carbonate isolated incl taking out old unsv ceiling rose all as specified and directed.
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl taking out old unsv holder .
S&F in replacement dimmer type electronic fan regulator flush incl taking out old unsv dimmer all as specified and directed .
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed.
S&F in replacement LED tube light fitting bright 18 watt slim elegant design and provision of two round/square PVC boxes 2 cm in depth and including connected with 2 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed .
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement MCB 6-32 amps, 10 KA, SP 240 volt, 'B' series all as specified and directed.
Supply and fix in replacement MCB 32-40 amps, 10 KA, SPN 240 volt, 'B' series all as specified and directed.
M & L in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to earth lead strip 32x6 mm by lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by medium grade galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth strip and protection pipe beyond 7.5 mtr will be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)
M&L for point wiring in replacement in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, flexible pipes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels including taking out old unsv wiring all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 48 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 48 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 48 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush incl taking out old unsv regulator all as specified and directed.
S&F in replacement of 3 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed.
S&F in replacement of 7 watt LED bulb. cool day light, 230/240V AC supply all as specified and directed.
S&F in replacement LED tube light fitting 2 feet 10 watt slim elegant design, including provision of two round/square PVC boxes 2 cm in depth and including connected with 2/3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fixing in replacement 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light square type of suitable site as per site requirement complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with two/three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, TPN 4 way vertical type with single/three phase outgoing with provision for MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement MCB 63 amps, 10 KA, SPN 240 volt, 'B' series all as specified and directed .
Supply and fix in replacement MCB 63 amps, 10 KA, TPN 240 volt, 'B' series all as specified and directed Make:-Legrand/Schneider/ HPL
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed. Note :- Defective parts like PVC flexible pipe, inner tank, thermal auto cut, indication lamp, heating element, circular ring , gyser assembly, bottom plate etc.shll be measured and paid separately
Supply only PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply only PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix in replacement of stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
Supply only inner tank 9 holes suitable for Geyser 25 liters capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only inner tank 6 holes suitable for Geyser 25 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only inner tank 9 holes suitable for Geyser 35 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only inner tank 6 holes suitable for Geyser 35 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only Inner tank 9 holes suitable for Geyser 50 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only Inner tank 6 holes suitable for Geyser 50 litres capacity incl Apparatus assembly made of copper Make : Usha/Lexus/Crompton
Supply only indication lamp (Green/Red) as per required at site all as specified & directed.
Supply only thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
Supply only geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
Supply only geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
Supply only circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
Supply only bottom plate as per existing size (ISI Marked) all as specified and directed
Supply only Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
Supply only Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle shall be measured and paid separately
Supply only ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed Make : SKF/TATA/Universal/polar
Supply only condenser capacity 4 MFD/ 3.15 MFD/ 2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with two coats of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L for burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
Supply only blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed. (ISI Marked)
Taking down carefully unserviceable ceiling fans of 1200/1400mm sweep from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- motor rewinding and condensor will be measured and paid separately.
M&L for rewinding ceiling fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 1200/1400 mm sweep including suitable size of bearings all as specified and directed.
Taking down carefully unserviceable Wall mounted fans of 300/400mm sweep from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- motor rewinding and condensor will be measured and paid separately.
M&L for rewinding Wall mounted fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 300/400 mm sweep including suitable size of bearings all as specified and directed.
Taking down and dismantling of refrigerator/deep freezer of capacity 160-320 litres of capacity after disconnecting of electric connection for servicing, overhauling washing Cleaning with new gasket of door, unserviceable tray change with new tray as per site refrigerator and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts all as specified and directed. Note:- Defective parts like capacitor, compressor, condensing coil, fan motor, blower motor, fan blade and gas charging will be measured and paid separately under relevant item of schedule as supply only items.
Supply only compressor suitable for 160-320 litres capacity refrigerator. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Supply only capacitor (starting/running) suitable for 160-320 litres capacity refrigerator (ISI Marked) all as specified and directed. Make : Voltas/Zeco/Blue Star
Supply only condensing coil assembly suitable for 160-320 litres capacity refrigerator all as specified and directed. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Supply only GAS charging (R-24/134A) suitable for 160-320 litres capacity refrigerator all as specified and directed.
Supply only PVC/Iron fan blade suitable for 160-320 litres capacity of refrigerator. (ISI Marked) all as specified and directed.
Supply only fan motor/blower motor suitable for 160-320 litres capacity of refrigerator all as specified and directed. Make : BLUE STAR/WHIRPOOL/VOLTAS/SAMSUNG
Taking down and dismantling of 1.5 Ton capacity air conditioner after disconnecting of electric connection for servicing, overhauling washing cleaning with blower and gas charging and refixing the same to its original position commissioning and testing after replacement of unserviceable parts. Note :- Defective parts like capacitor, compressor, condensing coil , fan motor, blower motor, fan blade, and gas charging will be measured and paid separately under relevant item of schedule as supply only items
Supply only compressor complete suitable for 1.5 Ton Capacity split Air conditioner complete all as specified and directed. Make : VOLTAS/BLUE STAR/CARRIER
Supply only capacitor (Starting/running) complete suitable for 1.5 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed.
Supply only condensing coil assembly complete suitable for 1.5 Ton Capacity Air conditioner complete all as specified and directed. Make : VOLTAS/BLUE STAR/CARRIER
Supply only GAS Charging (R-22/R-32) complete suitable for 1.5 Ton Capacity Air conditioner complete all as specified and directed.
Supply only PVC Fan blade complete suitable for 1.5 Ton Capacity Air conditioner (ISI Marked) complete all as specified and directed.
Supply only Fan Motor/Blower motor complete suitable for 1.5 Ton Capacity Air conditioner complete all as specified and directed.
M/S Swarn Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .