DGM TOS and Disposals
DGM TOS and Disposals, TOS, Kagithapuram
Miscellaneous Electrical works in Factory, Colony, Intake well, BR3 and Clonal Plant for the year 2022 to 23
2022_TNPL_255400_1
TNPL/TOS/U1/222313003845
Open Tender
Support/Maintenance Service
Tender cum Auction
365 days
Kagithapuram
As per pre qualification document
8 documents required · 8 mandatory
₹590
TNPL
₹95,000
21 Dec 2022
8 Oct 2022
14 Nov 2022
8 Oct 2022
12 Nov 2022
8 Oct 2022
Amount
Miscellaneous Electrical works in Factory, Colony, Intake well, BR#3 and Clonal Plant for the year 2022-23
Cable laying work: Laying of L.T. Power/ control cables-for laying, dressing and clamping of cables-in racks, trays in concrete shafts/underground (excluding excavation & back filling)-upto 2.5 sqmm
Cable laying work:Laying of L.T.power /control cables-for laying, dressing&clamping of cables- in racks, trays, in concrete shafts/underground (excluding excavation&back filling)-above 2.5sqmm upto 35sqmm
Cable laying work:Laying of L.T.power/ control cables-for laying, dressing&clamping of cables- in racks, trays, in concrete shafts/underground (excluding excavation&back filling)-above 35sqmm upto 95sqmm
Laying of L.T. Power/ control cable/ telephone cables including charges for dressing & clamping in racks, trays, concrete shafts/underground(excluding excavation & back filling )-above 95sqmm
Cable Trays, Supports, Frames and Misc. Steel Fabrication Works: Cable removal / fixing / replacement of push button stations and/or canopy for the same.
Fabrication and erection of MS cable trays, supports, frame and Misc. Steel fabrication work including one anti-rust coat of primer, two finished coats of approved enamel paint
Cleaning of slots and preparing stator for rewinding - Upto 10KW
Cleaning of slots and preparing stator for rewinding - Above 10KW and Upto 30 KW
Cleaning of slots and preparing stator for rewinding - Above 30KW and Upto 75 KW
Cleaning of slots and preparing stator for rewinding - Above 75KW
Removal of armoured aluminium cable from trays/underground(excluding excavation)&wind the removed cable in drum/as coil&shifting it to cable yard/other location as instructed - 3.3 KV, 3core x120sqmm cable&abv
Removal of armoured aluminium cable from trays/underground(excluding excavation)&wind the removed cable in drum/as coil&shifting it to cable yard /other location as instructed - 11 KV,3corex300 sqmm Cable&abv
Concealed wiring: Laying and Wiring in PVC concealed conduit of appropriate size between Main switch boards for single phase supply using 4.0 or 6.0 sqmm wire along with earth wire .
Concealed wiring: Laying and Wiring in PVC concealed conduit of appropriate size between Main switch boards for Three phase supply using 4.0 or 6.0 sqmm wire along with earth wire
Concealed wiring: Telephone wire in concealed PVC conduit - For single run (One Cable)
Concealed wiring: Telephone wire in concealed PVC conduit - For additional runs (more than one cable) in the same PVC Pipe
Surface wiring (Casing Capping or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit - For single run (One Cable)
Surface wiring (Casing Caping or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit – For additional runs (more than one cable) in the same PVC Pipe / casing caping
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds (excluding excavation) - above 35 sqmm & upto 95 sqmm
Removing the following LT cable / telephone cable from racks/ trays concrete trenches/overhead trays/ vertical shafts/undergrounds(excluding excavation) - above 95sqmm.
Surface wiring:Laying and Wiring in PVC Conduit or Casing Capping of appropriate size between Main switch boards for single phase supply using 4.0 or 6.0 sqmm wire along with earth wire
Surface wiring:Laying and Wiring in PVC Conduit or Casing Caping of appropriate size between Main switch boards for Three phase supply using 4.0 or 6.0 sqmm wire along with earth wire .
Wiring in Industrial area:Wiring of armoured / power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire – 1 phase power socket.
Wiring in Industrial area:Wiring of armoured / power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire - 3 phase power socket.
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire - MV/SV /CFL/LED lamp.
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including fixing of switch board&fitting for the following along with earth wire- single/twin tube light
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including fixing of switch board&fitting for the following along with earth wire- fan®ulator/exhaust fan.
Earthing:Excavation of 2.75Mtr depth,filling with charcoal&clay,erecting electrodes,backfilling, providing necessary brick work&connection with G.I/copper Strip from earth pit to main grid(excluding electrode)
Earthing:Installation of equipment grounding for indoor&outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators, trays&grounding of structures - Earthing using 25x3GI/copper
Earthing:Installation of equipment grounding for indoor&outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators, trays&grounding of structures- Earthing using 50x6 GI/copper.
Fixing of 63 Amps power plug unit (Fabrication, fixing frames, welding and fixing the switch)
Fixing of pull chord rope hook (Fabrication of hooks & welding)
Fixing of pull chord switch (Fabrication, fixing angles, welding & fixing the switch)
Installation and commissioning of Main Switch Board consisting of Main switch, one or more fuse cut outs, ELCB and meter - 1 phase
Installation and commissioning of Main Switch Board consisting of Main switch, one or more fuse cut outs, ELCB and meter - 3 phase
Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays (including dressing of cables) / underground (excluding excavation) - 3.3 KV, 3 core x 120 sqmm cable & above
Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays (including dressing of cables) / underground (excluding excavation) - 11 KV, 3 core x 300 sqmm cable & above
Painting of Motors -cleaning the surface, applying one coat of red-oxide paint& two coats of smoke grey paint (supply of paint by TNPL). Use of thinner for any exigency - shall not exceed 3% - upto 10KW
Painting of Motors -cleaning the surface, applying one coat of red-oxide paint&two coats of smoke grey paint (supply of paint by TNPL). Use of thinner for any exigency shall not exceed 3% - Abv 10KW & upto30 KW
Painting of Motors - cleaning the surface, applying one coat of red-oxide paint&two coats of smoke grey paint (supply of paint by TNPL). Use of thinner for any exigency shall not exceed 3% - Abv 30KW&upto 75KW
Painting of Motors : Cleaning the surface, applying one coat of red-oxide paint&two coats of smoke grey paint (supply of paint by TNPL). Use of thinner for any exigency shall not exceed 3%abv 75KW & upto 160KW
Painting of Motors : cleaning the surface, applying one coat of red-oxide paint&two coats of smoke grey paint (supply of paint by TNPL). Use of thinner for any exigency shall not exceed 3% -abv 160KW&HT motors
Installation of street light poles with a pole pit of 0.75x0.75x1.0M, erection of pole, concreting with 1:3:6 mix, cutting&bending of 50mm dia GI pipes for loop in/loop out in marshaling box, fixing&erection
Street Light : Dismantling of street light poles.
Post top lantern/70W street light fitting:Installation of abv luminaire on MS/GI post with a pole pit of 0.5x0.5 x0.5Mtr. Concreting with 1:3:6 mix, installation of marshaling box with loop in&loop out cabling.
Post top lantern / 70W street light fitting: Dismantling of post top lantern/70W Street light fitting.
Excavation & back filling of cable trench upto depth of 1Mtr including removal of old sand&bricks, re-laying the same/providing inverted V- shaped concrete coverings supplied by TNPL wherever required.
Excavation upto depth of 1Mtr for laying the armoured cables of all sizes&for communication cables wherever necessary 2" sand cushioning&3 side brick laying, refilling trench including cost of sand, brick etc.
Cutting of blacktop / concrete road and excavation upto a depth of 1mtr for laying pipes for cable crossing and refilling trench excluding repair of blacktop / concrete
Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Meter
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds ( excluding excavation) - upto 2.5 sqmm
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds (excluding excavation) - above 2.5 sqmm & upto 35 sqmm
Surface wiring:Laying&Wiring in PVC Conduit / Casing Caping between Main switch board&sub-main switch board to individual light/fan/power socket etc. using 1.5 /2.5sqmm wire along with earth length upto 5Mtrs.`
Surface wiring:Laying&Wiring in PVC Conduit / Casing Caping between Main switch board&sub-main switch board to individual light/fan/power socket etc. using 1.5/2.5sqmm wire along with earth length upto 10Mtrs.
Concealed wiring:Laying&Wiring in PVC concealed conduit between Main switch board&sub main switch board to individual light/fan/power socket etc.using1.5 or 2.5sqmm wire along with earth length upto 5Mtrs.
Concealed wiring: Laying&Wiring in PVC concealed conduit between Main switch board & sub main switch board to individual light/fan/power socket etc. using 1.5/2.5sqmm wire along with earth length upto 10Mtrs.
Termination of LT cable on both ends / straight through joint - upto 2.5 sqmm
Termination of LT cables on both ends / straight through joint - Above 2.5 sqmm & upto 35 sqmm
Termination of LT cables on both ends / straight through joint - Above 35 sqmm & upto 95 sqmm
Termination of LT cables on both ends / straight through joint - Above 95 sqmm
Termination of HT cables on both ends / straight through joint - 3.3 KV grade cable
Termination of HT cables on both ends / straight through joint - 11 KV grade cable
Wiring in Industrial area: Removal of scrap copper wire from the defective electrical motors of capacity - Upto 10 KW
Wiring in Industrial area: Removal of scrap copper wire from the defective electrical motors of capacity - Above 10KW and Upto 30 KW
Electrician for colony Electrical Maintenance work
Electrician for clonal plant
Fixing extra power socket with switch(5A/15A) in addition with concealed/ surface wiring between main switch board & sub main switch board to individual power socket with switch using 1.5/2.5sqmm wire.
Dismantling and fixing of 70W / 150W / 250W / 400W light fittings with control gear at elevation upto 30 Mtr
Replacing of Bulb/lamp in Industrial light fitting/ Tower light fitting upto 30 Mtr Elevation
Replacement of MCB/Fault attending in the Industrial light fitting upto 30 Mtr Elevation
Man power for Telephone Exchange (Skilled)-ITI
Bidder Name
Amount in Words
Ravi Engineers and Contractors
NVN ELECTRICALS
Ravi Engineers and Contractors
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .