Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹8.6 L
EMD Value
₹17,176
Closing Date
10 Mar 2020, 2:00 pmClosed
EXECUTIVE ENGINEER
INDIAN INSTITUTE OF MANAGEMENT CALCUTTA, ENGINEERING DIVISION, D.H.ROAD, P.O. JOKA, KOLKATA - 700104
Annual Maintenance and Servicing of different type and model room AC, Water Cooler, Refrigerator, Deep freeze etc. at IIMC Campus
2020_IIMCT_549535_1
ED/IIMC/NIT/1/19-20/90 3rd Call
Open Tender
AMC/ Maintenance Contracts
Item Rate
365 days
IIM CALCUTTA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
IIMC CONSTRUCTION WORKS ACCOUNTS
₹17,176
IIM CALCUTTA, ENGINEERING DEVISION, JOKA
12 Mar 2020
3 Mar 2020
11 Mar 2020
3 Mar 2020
10 Mar 2020
3 Mar 2020
6 Mar 2020
Amount
Overhauling of window room/split AC as detailed below :- I. Opening the unit and dismantling the parts inside. II. Thorough washing / scrubbing and cleaning of unit / overhauling of fan motor. III. Providing bitumen compound on base tray including rubber support , clip etc. IV. Painting on sheet metal body & cleaning (both sides) by Berger /ICI approved make enamel paint. V. Re – assembling the unit, electrical wiring, testing and re - installation of the unit properly. Details as mention on NIT
Overhauling of Water Cooler, Refrigerator and Deep freeze etc as detailed below :- I. Opening the unit and dismantling the different parts. II. Scrubbing, washing and cleaning of sheet metal body and structure. III. Painting the full metal body , spare by Berger / ICI make enamel paint. IV. Overhauling of fan motor. V. Re - assembling, testing, new wiring ,re – installation with necessary connection in complete including rubber , clip etc. (Details as mention on NIT)
Supply , fitting, fixing of different Refrigeration / Air conditioning spare & components in place of defective ones as following:-
(A) Compressor starting relay :- I. Box type for AC units (Arvind / Ranutrol)
(A) Compressor starting relay :- II. Box type for Refrigerator / Deep freeze / Water Cooler (Arvind / Ranutrol)
(A) Compressor starting relay :- III. Open type with overload protection for Refrigerator, / Deep freeze /Water Cooler (Arvind / Hitech)
(B) Three core round PVC insulated Copper wire(flexible) as per following :- I. 1.5 sq. mm (KDK)
(B) Three core round PVC insulated Copper wire(flexible) as per following :- II. 2.5 sq. mm (KDK)
(B) Three core round PVC insulated Copper wire(flexible) as per following :- III. Fixing charge of wire (for Dept.supply of wire)
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- I. Above 20 MFD upto 40 MFD
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- II. Above 40 MFD upto 80 MFD
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- III. Above 80 MFD.
(C) Supply of compressor starting capacitor (Aluminium base, Make- Sarada/ Havells) of following capacity :- IV. 6-20 MFD
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- I. Above 30 MFD
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- II. Above 20 MFD upto 30 MFD.
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- III. Above 6 MFD upto 20 MFD.
(D) Supply of Compressor/ blower motor running capacitor (Aluminium base , Make-Sarada/ Havells) of following capacity :- IV. 4 – 6 MFD.
(E) Supply of Overload protector for following types of Compressor:- I. 0.75 to 2TR capacity. (Sriram)
(E) Supply of Overload protector for following types of Compressor:- II. 1/6 TR / 1/3 TR / ½ TR / ¼ TR capacity (Sriram)
(G) Supply of air filter for window / split AC unit.
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- I. WRAC / SAC unit (switch make-Renutrol / Annapurna).
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- II. Water cooler (switch make-Renutrol / Annapurna).
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- III. Deep Freeze (Switch make-Renutrol / Infoss).
(H) Supply of Auto thermostat switch for following different capacity Refrigerator/ water cooler / Deep freeze/ Air conditioning unit :- IV. Refrigerator (Renutrol / Infoss).
(I) Supply of front grill cover compatible with the running WRAC / SAC units.
(J) (i) Supply of base tray for AC units (size and iron sheet gauge thickness as per original tray used.
(J) (ii) Supply of cabinet for AC unit (size and iron sheet gauge thickness as per original cabinet used)
(K) Supply of following spare for AC unit blower motor :- I. Condenser fan blade (same as per original sample).
(K) Supply of following spare for AC unit blower motor :- II. Evaporator runner (same as per original sample).
(L) Supply of Fan blade for Water cooler / Deep Freeze / Freeze. (same as per original sample).
(M) Supply of Inlet /outlet water tap (Brass) for Water cooler.
(N) Supply of Float valve (Brass with brass nipple) for Water cooler.
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (i) WRAC/SAC unit.
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (ii) Water cooler/Deep Freeze.
(O) Supply and fixing of blower motors (Crompton Greaves / Universal / DLF) for the following :- (iii) Compressor cooler (Deep Freeze).
(P) (i) Supply of Blower motor with blade (approved brand) for frost free Refrigerator.
(P) (ii) Supply of PTCR (approved brand as per original sample)
(Q) Supply and fixing of new Compressor (Carrier/Hitachi/ Kirloskar) for AC / Water cooler / Refrigerator / Deep Freeze as mentioned below :-
a. Reciprocating type : i. Above 0.5 TR upto 1 TR
a. Reciprocating type : ii. Above 1 TR upto 2 TR
a. Reciprocating type : iii. Upto 0.5TR
a. Rotary type : (i) Upto 1 TR
a. Rotary type : (ii) Above 1 TR upto 2 TR (Job under Q includes complete work with new capillary tube , strainer , charging of refrigerant gas etc. Original challan of compressor to be produced)
(R) Supply, fitting and commissioning of AC / SAC’s condensing unit (Copper tube as per sample design) including Capillary tube , strainer & Refrigerant Gas charging to set right the following AC to work satisfactorily. (i) Above 1 TR upto 2 TR AC
(R) Supply, fitting and commissioning of AC / SAC’s condensing unit (Copper tube as per sample design) including Capillary tube , strainer & Refrigerant Gas charging to set right the following AC to work satisfactorily. (ii) upto 1 TR AC/WC
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl. leg rubber,clip,connector etc) :- (j) Above 0.5 TR upto 1 TR Capacity
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl. leg rubber,clip,connector etc) :- (ii) Above 1 TR upto 2 TR Capacity
Repairing of defective / burnt compressor after dismantling including replacement of motor winding, big & small end bush, suction & discharge reeds, compressor oil and re – installation of the same for the following (incl. leg rubber,clip,connector etc) :- (iii) Upto 0.5 TR
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- i. WRAC / SAC unit blower motor
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- ii. Water cooler/Deep Freeze/ B. Motor etc.
Repairing of damaged / burnt blower motor including rewinding of Armature coil, heat varnishing, Supply & fixing Gun – metal bush and refitting complete :- iii. SAC (indoor unit)
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- i. 0.5 TR / 0.75 TR / AC & WC Compressor.
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- ii. 1.0 TR / 1.5 TR Compressor (WR AC)
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- iii.g1.5 TR / 2 TR Compressor (SAC)
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- iv. Water cooler / Deep Freeze.
Supply & charging refrigerant gas of the following Refrigeration / AC unit including supply and fixing of capillary pipe, strainer / drier, leak testing, N2 flashing etc. as required to complete the job:- v. Refrigerator
Repairing of sheet metal body & structure of different type, model, capacity of Water cooler/Refrigerator/ Deep Freeze & AC. All sheet metal jobs to be done by 20 SWG GI sheet & MS angle per original size, shape where it will be fitted. Rate incl.2 coats approved make & brand synthetic enamel paint with 1 coat Red Lead primer as follows :-
A. For water cooler (upto 80 lts. capacity) :- (i) Repairing portion with volume more than 75 % of body.
A. For water cooler (upto 80 lts. capacity) :- (ii) Repairing portion with volume above 50% upto 75%
A. For water cooler (upto 80 lts. capacity) :- (iii) Repairing portion with volume between 30 % to 50% of body.
A. For water cooler (upto 80 lts. capacity) :- (iv) Repairing portion with volume less than 30 % of body.
B. For Cabinet & body of WR unit :- (i) Repairing portion with volume more than 70% of body.
B. For Cabinet & body of WR unit :- (ii) Repairing portion with volume between 40% to 70 % of body.
B. For Cabinet & body of WR unit :- (iii)Repairing portion with volume less than 40% of body.
(a) Repairing and minor sheet metal job / patch work for all type of mode Refrigerator / Air conditioner unit.
(b) Supply and fixing wooden frame (made by 2” X 4” Sal wood) in place of existing broken / damaged frame including installation & electric connection complete.
(c) Supply and fixing wooden frame (made by 2” X 4” Sal wood) including wall / grill cutting, plastering and allied work to complete the proper installation of any make & capacity WRAC unit with electric connection complete.
(d) Installation of WRAC unit in place of existing other make unit with allied work and electrical connection complete.
(e) Dismantling of Hi-wall / Floor mounted SAC machine & re-install the same at new location including necessary materials , refrigerant gas, bracket etc. complete in all respect for satisfactory performance of AC.
A. Replacement of internal electrical wiring of RAC / Water cooler / Refrigerator / Deep Freeze unit including necessary, Brass terminal clip, connector, insulating tape and connection complete.
B. (i). Replacement of Door gasket only of Water cooler.
B. (ii) Replacement of Magnetic Door gasket only of Refrigerator / Deep Freeze.
(C) Replacement of body insulation of RAC unit with necessary pasting materials and related work complete in all respect. (i) 50% and above of total insulated area.
(C) Replacement of body insulation of RAC unit with necessary pasting materials and related work complete in all respect. (ii) Less than 50% of total insulated area.
Lifting and shifting charges of WRAC / Water cooler / Refrigerant / Deep Freeze for delivery after repairing the unit. (Excluding : Installation unit , overhauling unit)
Routine checkup, cleaning & servicing of WRAC / SAC / WC / Refrigerant / Deep Freeze an instructed by Engg. In Charge.
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- I. Attend but failed to start & run.
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- II. Attend rectified the fault & successfully completed the job.
Breakdown call attending of any type, make and capacity Refrigerator & Air conditioning unit as details below:- III. Attend, made it ok & servicing the unit.
Through scraping, cleaning & painting of WR AC unit, protective grill, case by paint 1 coat of Berger Red Lead primer (Paint should be approved make)
Supply and fixing of WR AC unit water tray (made of 20 SWG GI sheet) with adequate size outlet vent.
Providing of suitable waste water drain line (made by PVC water pipe & of approved brand) on the wall by saddling 1 Mt. apart including necessary attachment to complete the job. I. 12 mm PVC pipe line
Providing of suitable waste water drain line (made by PVC water pipe & of approved brand) on the wall by saddling 1 Mt. apart including necessary attachment to complete the job. II. 19 mm PVC pipe line
Fixing of waste water tray of RAC including drain line pipe.
Supply and fixing of the following Electrical accessories :- (i) 6-10 A , three pin plug top (Anchor)
Supply and fixing of the following Electrical accessories :- (ii) 16-20 A , three pin plug base (Anchor)
Supply and fixing of the following Electrical accessories :- (iii) Single core flexible copper wire 2.5 sq. mm FRLM(Finolex)
Supply and fixing of the following Electrical accessories :- (iv) Single core flexible copper wire1.5 sq. mm FRLM (Finolex)
Any work to be done at site on emergency basis in connection with AC / Cooler / Deep Freeze / Refrigerator which is not a part of the Schedule will be executed as and when required. (Rates will be ascertained on the basis on rate analysis as per prevailing market rate/ submission of original bill ) and payment will be made as per actual work at site duly supported by relevant papers (eg. Cash memo/ bills etc. 10 % profit will be given on the cost of original bill )
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .