Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
1 Feb 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager SRC-OS
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Works on MSB and ESB on ORV SINDHU SADHANA
2024_HSL_94050_1
20 / 22019 / 065 / MSB and ESB / 2023-24
Open Limited
Miscellaneous Services
Service
20 days
HSL Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹525
Yes
HSL
₹10,000
Yes
7 Mar 2024
9 Jan 2024
1 Feb 2024
9 Jan 2024
1 Feb 2024
9 Jan 2024
Amount
Main Switch Board ( 400 Volt & 230 Volt) Name Plate Details: MARINE ELECTRICALS, MUMBAI Special Requirements and Conditions: All meters to be calibrated. if defective meters found need to be renewed. Calibration certificate to be issued for the same. Volt meter : 9 Nos Ammeter : 8 Nos KW meter : 5 Nos Frequency meter : 7 Nos Earth Fault meter : 4 Nos Work Scope : Check the tightness of all the connections in the bus bar. Bus bar must be made free from dirt by vacuum cleaner and electro chemical. The Earth fault system of 3Phase 400v, 50Hz & 230v, 50Hz to be checked for earth fault alarm and the low insulation circuit to be identified and rectify the problem. Renew spares if required. All earth fault system should be working normal. All spares under vendor scope.
Main ACB ( 6 Nos) to be overhauled. (ie : 4 for DGS & 2 for AT) AC 23A, Ue 690 Volt, Ie 2500 Amps. Make : Schneider Electric, NW 25 H2, U1 1000 V, Uimp 12 KV, The job includes all the protection of the alternators and MSB safeties to be tried out. (ie: under voltage, over voltage, Under frequency, over frequency, over load, over current, reverse power trip and preferential trip etc ). During above exercise, if any defect found and same to be rectified. All spares under vendor scope.
MSB & ESB distribution MCCB operating knob defective, need to renew. Make: Schneider electric, Model NSX100N - 3 no.s and NSX100H - 2 no.s All spares under vendor scope.
Motor starter panel CT coils defective and erratic value showing in VAF meter same need to renew with new one. And defective VAF meter renewed with new one. All consumable spares in Vendor scope. And remote start/stop push button with indication lamps in ECR for pumps need to renew. Total starter panel: 20 no's. s/w pump no-1 and 2 remote start/stop box to be renew near pump location VAF METER MAKE: SELEC, MODEL: VAF39A-1 CT COIL MAKE: MAYUR, TYPE: RING, RATIO: 50/5, LINE: 0.66KV, FREQ: 50HZ CLASS:1 BURDEN: 5VA. All spares under vendor scope.
Emergency Switch Board (400 Volt & 230 Volt) Name Plate Details: MARINE ELECTRICALS, MUMBAI Special Requirements and Condition. Check the tightness of all connection in the bus bar. Bus bar to be cleaned by vacuum cleaner and electrosolve chemical. All meters to be calibrated in ESB and if any defective meters found same to be renewed. EDG ACB ( 400 A ) need to be serviced. The job includes all the protection of the alternators and ESB safeties to be tried out. Calibration certificate to be issued for the same. Voltmeter : 5 Nos Ammeter - 5 Nos Earth Fault Meter : 2 Nos Frequency Meter : 1 No(Need to renew) All spares under vendor scope.
DELTA MARINE ENGINEERS
SRI VINAYAKA MARINE SERVICES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .