Loading…
Loading…
Tender Value
₹2.9 L
EMD Value
₹5,773
Closing Date
5 Oct 2026, 11:00 am
AC(Electrical) FTR HQ BSF RAJASTHAN
AC(Electrical) FTR HQ BSF RAJASTHAN,Mandore Road,Jodhpur-342026
Repairing and Relaying of UG Cable at BSF Campus Jodhpur under FTR HQ BSF Rajasthan.
2026_BSF_927612_1
29/AC(E)/FTR-RAJ/2026-27
Open Tender
Electrical Works
Item Rate
60 days
IG FTR HQ BSF Jodhpur
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹5,773
Yes
24 Sept 2026
24 Sept 2026
6 Oct 2026
24 Sept 2026
5 Oct 2026
24 Sept 2026
24 Sept 2026 - 5 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 35 sq. mm and upto 95 sq. mm | 70 | Metre | - | - |
| 2 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm | 16 | Metre | - | - |
| 3 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm) | 1 | Each | - | - |
| 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 120 sq. mm (45mm) | 2 | Each | - | - |
| 5 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 16 sq. mm | 5 | Each | - | - |
| 6 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 25 SQ MM | 1 | Each | - | - |
| 7 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5 x 35 SQ MM | 4 | Each | - | - |
| 8 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5 X 120 sq. mm | 6 | Each | - | - |
| 9 | Excavation including refilling the cable trench for deducting the fault that occurs in existing PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade cable and taking the cable out from trench, repairing the existing cable and relaying the cabe in same trench including connection etc as required as per direction of Engg-in-charge. Upto 35 Sqmm | 73 | Metre | - | - |
| 10 | Excavation including refilling the cable trench for deducting the fault that occurs in existing PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade cable and taking the cable out from trench, repairing the existing cable and relaying the cabe in same trench including connection etc as required as per direction of Engg-in-charge. Above 95 Sqmm to Upto 185 Sqmm | 225 | Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
BOQ_974795.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .