Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 LAccepted-AOC DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | 1 | Accepted-AOC being L1 | |
| 2 | 2₹5.2 L+₹20,550 (4.10%)Rejected-Finance | 2 | Rejected-Finance Rejected being other than L1 | |
| 3 | 3₹5.3 L+₹26,160 (5.22%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | 3 | Rejected-Finance Rejected being other than L1 | |
| 4 | 4₹5.8 L+₹75,900 (15.1%)Rejected-Finance | 4 | Rejected-Finance Rejected being other than L1 | |
| 5 | 5₹6.0 L+₹98,600 (19.7%)Rejected-Finance | 5 | Rejected-Finance Rejected being other than L1 |
| Sl No | Description | Qty | Unit | K VENUGOPALA SWAMY L5 | M/S SIRI BUILDERS L3 | DHANA CONSTRUCTIONS L4 | PAVANI INFRAS L2 | BEST ENGINEERING L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for under ground electric cable, pipes etc.complete all as specified & directed. | 100 | Cum | 450 ₹45,000 | 480 ₹48,000 | 260 ₹26,000 Lowest | 450 ₹45,000 | 450 ₹45,000 |
| 2.00 | Returning, filling-in, including, spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified & directed. | 90 | Cum | 165 ₹14,850 | 180 ₹16,200 | 80 ₹7,200 Lowest | 200 ₹18,000 | 150 ₹13,500 |
| 3.00 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. | 10 | Cum | 420 ₹4,200 | 380 ₹3,800 | 150 ₹1,500 Lowest | 400 ₹4,000 | 350 ₹3,500 |
| 4.00 | M&L in repair for Unplasticized PVC 25 mm pipes of pressure rating 10 kgf/Sq.Cm fixed complete to walls, ceilings or in floors etc., existing pipe of any type as per site requirement complete all as specified and as directed. | 50 | Rm | 200 ₹10,000 | 290 ₹14,500 | 280 ₹14,000 | 160 ₹8,000 Lowest | 170 ₹8,500 |
| 5.00 | -Do- But 32 mm | 50 | Rm | 250 ₹12,500 | 300 ₹15,000 | 320 ₹16,000 | 200 ₹10,000 Lowest | 200 ₹10,000 Lowest |
| 6.00 | M&L in repair for Unplasticized PVC 40 mm pipes of pressure rating 10 kgf/Sq.cm laid in trenches as per site requirement complete all as specified and as directed. | 60 | Rm | 270 ₹16,200 | 260 ₹15,600 | 400 ₹24,000 | 220 ₹13,200 Lowest | 280 ₹16,800 |
| 7.00 | -Do- But 50 mm | 120 | Rm | 320 ₹38,400 | 310 ₹37,200 | 460 ₹55,200 | 300 ₹36,000 Lowest | 350 ₹42,000 |
| 8.00 | -Do- But 63 mm | 20 | Rm | 450 ₹9,000 | 400 ₹8,000 Lowest | 560 ₹11,200 | 400 ₹8,000 Lowest | 400 ₹8,000 Lowest |
| 9.00 | -Do- But 90 mm | 20 | Rm | 650 ₹13,000 | 650 ₹13,000 | 560 ₹11,200 Lowest | 600 ₹12,000 | 780 ₹15,600 |
| 10.00 | -Do- But 110 mm | 20 | Rm | 750 ₹15,000 | 770 ₹15,400 | 600 ₹12,000 Lowest | 800 ₹16,000 | 750 ₹15,000 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
21 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2025_MES_734079_2
AGE(I)/SL/8680
Open Tender
Civil Works - Water Works
Works
180 days
SURYALANKA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) SURYALANKA
₹10,000
29 Nov 2025
7 Oct 2025
23 Oct 2025
7 Oct 2025
21 Oct 2025
14 Oct 2025
7 Oct 2025 - 12 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for under ground electric cable, pipes etc.complete all as specified & directed.
Returning, filling-in, including, spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified & directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
M&L in repair for Unplasticized PVC 25 mm pipes of pressure rating 10 kgf/Sq.Cm fixed complete to walls, ceilings or in floors etc., existing pipe of any type as per site requirement complete all as specified and as directed.
-Do- But 32 mm
M&L in repair for Unplasticized PVC 40 mm pipes of pressure rating 10 kgf/Sq.cm laid in trenches as per site requirement complete all as specified and as directed.
-Do- But 50 mm
-Do- But 63 mm
-Do- But 90 mm
-Do- But 110 mm
S&F in repair 110mm outer dia, ISI marked 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches or floors etc., including taking up existing unserviceable pipes of any type complete all as specified and as directed.
-Do- But 90 mm
-Do- But 75 mm
-Do- But 63 mm
S&F in repair 32mm outer dia, ISI marked 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking up existing unserviceable pipes of any type complete all as specified and as directed.
-Do- But 25 mm
S&L in repair Ductile Iron pipes 100 mm dia with spigot and socketed ends class k-9 in any length with internal cement motar lining and external zinc and bitumen coated confirming to IS:8239-2000 including push on rubber gasket joints and laid in trenches as per IS 12288 complete all as specified and as directed. Make: Tata Metaliks/ Jindal/ Electrosteel / Srikalahasthi
M&L for making suitable hole in Existing 150/100mm DI/CI pipe and fixing of Iron D Clamps with any ferrule size for tapping, including disconnecting the existing PVC/PPR/GI tapping pipe from PVC 110mm main pipe line by closing the old tapping with PVC dummy and reconnecting to ferrule with necessary accessories, fittings, Gaskets etc, excavation and refilling complete all as specified and directed. Note: Supply of D Clamp with Ferrule is measured under relevant item.
Supply of iron D Clamp made out of MS flat not less than 50mm width not less than 5 mm thick, suitable size for 100mm DI pipe, 25 mm GI socket welded to D clamp with necessary gaskets, nuts and Bolts for connection, including two coat of red oxide paint complete all as specified and directed.
S & F in repair Sluice valve 100mm dia, Class PN 1.6 complete set as per site requirement complete all as specified and as directed.
S & F in repair UPVC ball valve of size 50mm dia, 2 Inch long complete all as specified and as directed.
M&L in repair for Construction of valve chamber of size 1200 x 1200 x 1000 mm (internal dimension) suitable for 150/100 mm sluice valve, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, brick wall with sub class 'B ' bricks built in CM 1:4, PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping, plastering in CM 1:4,15 mm thick including provision of MS sheet cover 4 mm thick with two coat of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including excavation earth work in any type of soil, returning in filling and removing the surplus soil complete all as specified & directed.
PAVANI INFRAS (BID ID -3460134)
M/S SIRI BUILDERS (BID ID -3461679)
DHANA CONSTRUCTIONS (BID ID -3461148)
K VENUGOPALA SWAMY (BID ID -3460992)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
8680Tenderdoc.pdf
Tender Documents • 0.34 MB
8680PS.pdf
Additional Documents • 0.07 MB
BOQ_821966.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .