| 1 | L-1₹26.1 LAccepted-AOC SHYAM BHAWAN OPP BANK OF INDIA CHOPASNI ROAD JODHPUR 342003 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹26.6 L+₹48,314 (1.85%)Rejected-Finance HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L-2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L-3₹29.0 L+₹2.9 L (11.2%)Rejected-Finance KALATALAV TA ABDASA DIST KUTCH GUJARAT PIN 370 660 | KACHCHH | GUJARAT | 370660 | L-3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L-4₹30.4 L+₹4.3 L (16.5%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jul 2024, 6:00 pmClosed
GE (AF) Naliya No. 1
GE AIR FORCE STATION NALIYA NO 01
REPAIRING/REPLACEMENT OF INTERNAL WIRING FITTING AND FIXTURE AND FLAME PROOF LED LIGHTS, WIRING FITTING AND FIXTURE, SWITCH SOCKET, DBS AND CONNECTED EARTHING ITEMS AT TECH AREA AT AF STN NALIYA
2024_MES_659269_1
8986/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Naliya No. 1
₹60,000
Yes
13 Sept 2024
12 Jun 2024
13 Jul 2024
12 Jun 2024
10 Jul 2024
26 Jun 2024
Amount
Taking down copper/aluminum point wiring (light, fan, socket or power) complete and including (fitting and fixture such as switches, socket ,ceiling rose ,pendent ,regulators,light fittings, etc to be measured separetaly) NOTE:- Job including for taking out old gutties,screw,nails,casing caping/conduit etc and making good to disturbed surface of wall ,floor etc including to match with the existing surface complete all as specified and directed.
Material and labour for point wiring with 1.5 sq mm FRLSH single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including PVC box ISI marked of suitable size for mounting the switches , socket outlets , fan regulatorscomplete all as specified and directed for following :-
One light/Fan point controlled by one switch.
One socket 3 pin outlet 5 amp on independent board.
One light point controlled by two 2-way switches.
One 3 pin socket outlet 5 amp on the same board with other switches.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size
All as per serial item No 2.00 here-in-before but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm 2.5 sq mm copper cable as earth continuity conductor complete all as specified and directed.
Material and labour for point wiring for one light/Fan/socket 5Amps point on indep board controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FRLSH cable 1100 volts grade ISI marked drawn through and including heavy duty ERW conduit not less than 20 mm dia concealed type , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly complete all as specified and directed.. Note : Point wiring will be done from Main DB. Length of point wiring may be beyond 5 mtrs and no extra amount for long point wiring will be considered complete all as specified and directed.
Material and labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 1.5Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring complete all as specified and directed. Note: 02 Runs of main cable and one run earth wire with conduit will be measured as one Running Metre for payment complete all as specified and directed.
Material and labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring complete all as specified and directed. Note: 02 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix in replacement switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6,16A, 250V, 2P+earth complete all as specified and directed
Supply and fix in replacement LED Light Fittings1x16 Watt flame proof, CMRL certified recommended for gas/vapor group of IIA &IIIB Zone 1 & 2 , IP65 protectection with die cast aluminium housing with resistant toughened glass with, LED tube light fixture driver, holdes, connectors etc and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed.
Supply and fix in replacement LED Light Fittings 2x16 Watt flame proof, CMRL certified recommended for gas/vapor group of IIA &IIIB Zone 1 & 2 , IP65 protectection with die cast aluminium housing with resistant toughened glass with, LED tube light fixture driver, holdes, connectors etc and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed.
Supply and fix in repair/replacement of flame proof, weather proof type, distribution board, Aluminum die cast alloy in LM6 material sheet metal enclosure including MCB 63 Amp SPN (incomer) and 07 Nos SP 6-32 Amps (out going), terminal, wiring and all fitting accessories etc complete all as specified and as directed.
Supply and fix in repair/replacement of LED flame proof well glass in die cast aluminum housing with heat resistant toughened glass, 70watt , IP65 protected and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed.
Supply and fix flame proof, weather proof distribution board, Aluminum die cast alloy in LM6 material sheet metal enclosure including MCB 40 Amp, SPN (incomer) and 06 Nos SP 6-32 Amp (out going) terminal, wiring and all fitting accessories complete all as specified and directed.
Supply and fix flame proof, weather proof distribution board, Aluminum die cast alloy in LM6 material sheet metal enclosure including MCB 63 Amp, SPN (incomer) and 12 Nos SP 6-32 Amp (out going) terminal, wiring and all fitting accessories complete all as specified and directed.
Supply and fix in repair/replacement of LED flame proof well glass in die cast aluminum housing with heat resistant toughened glass, 60watt , IP65 protected and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed.
Supply and fix in replacement LED flood Light fitting 100 watt, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminum IP66 flood light, suitable for highlighting architectural facade and general purpose lighting and connected items complete all as specified and directed.
Supply and fix in replacment of switch piano flush type single pole one way 5 amp complete all as specified and directed.
Supply and fix in replacment of switch piano flush type single pole two way 5 amp complete all as specified and directed.
Supply and fix in replacment of ceiling rose three terminal/PVC polycarbonate, isolated body ccomplete all as specified and directed.
Supply and fix in replacment of switch socket combination 2 in 1, 3 pin 5/15 amp flush type complete all as specified and directed. .
Supply and fix switch socket combination 2 in 1,5 amp flush type complete all as specified and directed.
Supply and fix in replacment of socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type complete all as specified and directed.
Supply and fix in replacment of MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified and directed.
All as per item No 23 above but 4 way complete all as specified and directed.
Supply and fix in replacment of sheet metal enclosure 4 ways double door triple pole and neutral with 415 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified and directed.
Supply and fix in replacment of vertical type DB ,double door Suitable for isolated neutral bar 4 ways,IP 43 protection, Door earthing,mechenical impact strength IK 08 insulated busbar assembly ,fixed in the wall with suitable nut and bolt including 4 pole MCCB 125 Amp 16 KA fixed in DBs as incommer three phase supply fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified and directed.
Supply and fix in replacment of Isolater TPN 4 pole 100 amp complete all as specified and directed.
Supply and fix in replacment of Isolater TPN 4 pole 63 amp complete all as specified and directed.
Supply and fix in replacement of MCB single pole and neutral 35-63 amps, 240 Volts, complete all as specified and directed.
Supply and fix in replacement of MCB 6 to 32 amps single pole 240 Volts, complete all as specified and directed.
Supply and fix in replacement of switch bell push, flush type 5 Amp complete all as specified and directed.
Supply and fix in replacement of bell, AC, 230 Volts single pole complete all as specified and directed.
Supply and fix in replacement of lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified and directed.
Supply only LED Batten for LED tube light with 01 Nos of LED tube 18 Watt fixed on two Nos of Square Block with twin core copper flexible wire and incl taking down old type tube light fitting complete all as specified and directed.
Supply only LED plastic batten for LED tube light with 01 Nos of LED tube 10 Watt fixed on two Nos of Square Block with twin core copper flexible wire and incl taking down old type tube light fitting/holder any type complete all as specified and directed.
Supply and fix in replacement of LED street light fitting 20 W with pressure die cast housing along with prismatic polymer carbonate diffuser and LED with secondry optic with IP 65 protection, including provision of GI pipe light grade of suitable size bent to the shape fixed in the wall with two nos of clamps,nut,bolts,screw etc and taking down old UNSV street light fitting any type complete all as specified and directed.
Supply and fix in replacement of fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
Supply and fix in replacement of LED Post top lantern of 40 watt, warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection, including provision of suitable size of GI pipe medium grade and suitable length as required on the site fifed on the existing pillers by welding of four Nos of leg and fixed by using fastner and nut and bolts and neccessary connection with twin core copper cable multistranded 1100 volt grade complete all as specified and directed.
Supply and fix in replacement of 36W LED recessed 2x2 luminaire 6500K fixed in the existing Ciling/roofs white powder coated CRCA housing with LED seanless front frame with flat white transmissionacrylic cover and necessary connection with twin core copper cable of suitable size complete all as specified and directed.
Supply and fix in replacement sub main wiring drawing through PVC casing caping of suitable size with all fittings two run of single core 6 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 6 sq mm FRLS as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit and all accessories complete all as specified and directed.
Supply and fix in replacement sub main wiring drawing through PVC casing caping of suitable size with all fittings two run of single core 4 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 4 sq mm FRLS as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit and all accessories complete all as specified and directed.
Material and labour for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition complete all as specified and directed.
Checking and attending complaints by means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : (i) The electrician deployed by the contractor shall have ITI /05 years expreince certificate in concerned trade.Helperdeployed shall be min 8th pass with min 03 years expriance in relevant trade (ii) This item covers only cost of labour for attending complaint and taking down of old material. (iii) Item to be replaced under this item shall be either isued free for fixing under schedule 'B' or shall be contractor supply under respective items of this schedule as decided by Enge-in -charge. Decision of GE in this regard shall be final and binding. (iv) Complaints noted '' NO Light'' shall be attended imediately up to 2200 hrs without fail,failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill. (v) Minor items as PVC wire of any size as per requirement up to 1.0 Metre length,thimble,electric tape etc shall deemed to be included in the quoted rate of this items. (vi) The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be leived/imposed on the contractor and recovery shall be made from his dues. (vii) Contracror shall arrange suitable T&P incl necessary means of transport, ladder and safety measures to make it functional complete all as specified and directed.8. Contractor or his rep will report daily at complaint cell for collection of complaints from the concerned JE's incharge,in case after checking& attending the defects, if it is not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engeer in charge by the contractor/his rep immediately. If Engr -in -chargr is satisfied with contractor's view, no recovery will be made on this account. (viii) Labour charges for this item shall not be included under items which includes 'Material and labour', 'Suply and fix in repair', fixing only /fixing in repair in respective item of this Schedule/BOQ.
Supply only switch socket combination 5/15 A 250V AC universal with box in polycarbonate complete all as specified and directed.
Supply only switch piano flush type 5 amps single pole one way complete all as specified and directed.
Supply only switch socket combination multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
Supply only socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
Supply only electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers complete all as specified and directed.
Supply only replacement of capaciator 2.50 Mfd, 240 V complete all as specified and directed.
Supply only Hylem sheet 3 mm thick size 9'' x 11'' including cutting of switch, socket complete all as specified and directed.
Supply only Hylem sheet 3 mm thick size 8'' x 5'' including cutting of switch, socket complete all as specified and directed.
Supply only of Isolater TPN 4 pole 100 amp complete all as specified and directed.
Supply only Isolater TPN 4 pole 63 amp complete all as specified and directed.
Supply only MCB single pole and neutral 35-63 amps, 240 Volts, complete all as specified and directed.
Supply only MCB 6 to 32 amps single pole 240 Volts, complete all as specified and directed.
Supply only switch bell push, flush type 5 Amp complete all as specified and directed.
Supply only lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified and directed.
Supply only moduler switch 1 way 6A 1 module complete all as specified and directed.
Supply only moduler bell push 6 A, 1 module complete all as specified and directed.
Supply only moduler socket 6 A, 2/3 pin,2 module complete all as specified and directed.
Supply only moduler socket 6A/16A, 2/3 pin combined,2 module complete all as specified and directed.
Supply only moduler fan regulator 120 W. 2 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 1 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 2 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 3 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 4 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 6 module complete all as specified and directed.
Supply only moduler white cover plate with frame. 8 module complete all as specified and directed.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep including taking down old unserviceable board any type and removing the all unserviceable swinches sockets complete all as specified and directed. Note: New switchs, sockets, switch sockets mounting on the new board will be measured seprately.
Supply only PVC rectangular block for mounting switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover of size 200mmx150mmx50mm deep including taking down old unserviceable board any type and removing the all unserviceable swinches sockets etc all as directed. Note: New switchs, sockets, switch sockets mounting on the new board will be measured seprately.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 350mmx300mmx50mm deep including taking down old unserviceable board any type and removing the all unserviceable swinches sockets etc all as directed. Note: New switchs, sockets, switch sockets mounting on the new board will be measured seprately.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit with adequate quantity of charcoal and dust and common salt, not less than 2.25 mtr deep below ground level connected to & using galvanised iron strip 25×4mm as earthing lead drawn through GI protection pipe of size ordered specified for protection of earthing lead from earth electrode to test point/main DB from mechanical injury or tempering by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate No 5 of SSR Part - I and connected to earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting with earth point testing etc complete all as specified and directed. Note:- On testing after completion of earthing if desired earth resistance is not achieved, the earthing will be redone at no extra cost to obtain the desired earth values <5 ohms.
NILESH SUBHASH KARALE
Hari Construction
Krishna Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .