Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest Rate, Reasonable Rate | |
| 2 | L2₹5.1 L+₹17,100 (3.48%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹5.2 L+₹27,570 (5.61%)Rejected-Finance DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance 3RD LOWEST |
Tender Value
₹5.6 L
EMD Value
₹11,214
Closing Date
17 Sept 2024, 6:00 pmClosed
AGE (I) Raiwala
AGE (I) Raiwala
PROVN OF GENSET FOR SECURITY LIGHT IN ZONE A AND B OF RAIWALA MIL STN AND PROVN OF 01 X 1.5 TON SPILIT AC AT 6 MTN ARTY BDE SIG COY (TRUCK AUTOMATIC MANUAL ROOM) AT RAIWALA MIL STN
2024_MES_664787_1
8943/E8
Open Tender
Miscellaneous Services
Works
150 days
AGE (I) Raiwala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Raiwala
₹11,214
Yes
17 Dec 2024
9 Jul 2024
19 Sept 2024
9 Jul 2024
17 Sept 2024
26 Jul 2024
9 Jul 2024 - 24 Jul 2024
Amount
Supply ,install,commissioning and testing totally enclosed (silent operation with canopy,CPCB-IV+ compliant ),static type Diesel Engine driven,liquid cooled, Generating set of 10 KVA/8KW capacity accommodated within accoustic enclosure (at 0.8 lagging P.F) , 415V, 50 Hz, 3 Phase system & for 0.85 Load factor including AMF Panel , base plint as per manufacturer recommendation.(A) Diesel Engine :- Diesel Engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temprature of 50°C ,50% RH & at 1000m above MSL, conforms to BS:5514/ISO 3046, BS 649, IS 10000 with capacity of 10% overload for one hour in every 12 Hours of contineous operation. The engine shall have noise limit of 75 dB(A) at 1 metre (or complied with CPCB and Environmental norms as notified by GoI time to time), Emission limit ( NOx + THC or NOx + NMHC or RHC <= 4.0 g/kW-hr, CO <= 3.5 g/kW-hr , PM <=0.2 g/kW-hr and Smoke limit <=0.7 m¯¹ as applicable to diesel engine) notified by Min of Env vide GSR 281(E) dt 07 Mar 2016(and amendment thereof ,if any). The OEM shall undertake Type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced. The engine shall be engraved clearly as DIESEL on the cylinder block and a conformance label meeting the following requirement shall be affixed :-(a) Name and address of manufactuter of engine (b) Statement that the engine or product conforms to Env(Protection) Rules, 1986 (c) Type approval certificate number (d) Date of manufacture of engine (e) Rated speed and corresponding gross power in kW. The follwing accessories shall be as under :-(A1) Air Intake System.(i) Air intake manifold.(ii) Dry type air cleaner.(A2) Exhaust System.(i)Dry exhaust manifold with Residential silencer and catalytic converter.(A3) Cooling system.(i) Engine water pump.(ii) Radiator with Fan.(iii) Coolant additive concentrate.(A4) Lubricating system.(i) Oil pan.(ii)Engine mounted lube oil pump.(iii) Lube oil filter (A5) Starting System.(i)12/24 v DC Starter Motor, Voltage regultors.(ii)12/24v DC Alternator for Battery charging.(iii) 12V suitable maintenance free battery of suitable numbers.(A6) Engine mounted microprocessor based (preferably) Instrument panel with digital display for the following :-.(i) LED indicating lamps - for Genset running, remote start, shutdown, warning , manual, auto and stop.(ii) Data Logs - engine run time and controller on time.(iii) Start/Stop switch with Key.(iv) Indication/Display of - for water temp, lub oil pressure, Lub oil temp, Battery charging, RPM, Over speed, Low lub oil trip , Engine hours..(v) Engine and alternator Data - staring battery voltage, Engine running Hrs, Engine temp, Engine oil pressure, Alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) Protection to Genset.i) Low lube oil pressure warning/shutdown .(ii) High engine temp warning/shutdown.(iii) Low coolant temp warning (iv)Sensor failure indication.(v)Low/High battery voltage warning.(vi)Weak battery warning.(vii)Fail to start shutdown.(viii)Cranking lockout.(ix)High/Low AC Voltage shutdown.(x) Under/Over frequency shutdown.(xi)Loss of sencing volatge shutdown.(C) Others.(i) AVM Pads.(ii) First fill of lubricanting oils.(iii) Flywheel with housing.(iv) Residential silencer.(D) Alternator - Synchronous alternator copper wounded rated 10KVA, 415 Volts, 1500 RPM, 3 Phase , 50 Hz, AC Supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 1000 m MSL, brushless type, self exicited, SPDP encl, contineous duty, sel regulated through AVR conforming to IS:4722 with Class F/H insulation. The salient feature are as under : (a) Permanent lubricating bearing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) Permissible unbalancing capability minimum 25% per phase.(E) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable for 10 KVA capacity diesel Generator set duly fabricated of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- .(i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section ..(ii) Structure heavy duty rectangular MS box channel ..(iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks .(iv) Out side cover: Made out of CRCA sheet 2 mm thick. (v)Accustic insulation ( side &Top ) sound proofing mineral rock wool slab thickness 100mm of density 96Kg/m3 confirming to IS 8183 , covered by fire Resistant fiber tissue as per manufacturer recommendation .Test report from original manufacturer to be submitted before incorporation in the work for authenticity of material .(vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated .(vii) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel (viii) Sheet metal shall be eleven tank pretreated and powder coated.(F)AMF CONTROL PANEL:- As per manufacturer's design with the following options: (a) Start/ stop settings including delay and timing setting duly programmable.(b) programmable timing for idle running .(c) Auto/ manual option.(d) Self starting kiks for three times or as per programme .(e) Alarm for any fault with buzzer and indicating lamp .(f) One main supply voltage monitor .(g) One alternator supply voltage monitor .(h) One set of DC control relays and timers.(j) One set of control relays for the automatic control system .(G) FOUNDATION:- RCC Fuoundation M 20 ( or as per manufacturer design) ,250 mm overall height, 100mm above floor level and 150 mm below floor level of required size. (H) Acoustic Louvers / Attenuators at Air inlet/outlet :-The Hospital sparked grade acoustic frame spare and accessouries louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacture from 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts.(J) FUEL TANK :- One No of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load, tank shall be fitted with in canopy as per manufacturer's design including the following:-(i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for drain oil.(iii) fuel strainer.(iv) Pipe for fuel. (v) Air vent.(vi) Mannually operated one no. fuel pump.(K) INSPECTION PORT :- Aluminium box frame with double welded glass fix type sealed with EPDM/neoprene rubber gasket, for viewing instrument panel. NOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted .(b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted .(c) DG Set shall be placed at the site directed by Eng-in-charge which can be upto 20 meter from the road.(d) Testing of DG set shall be done as per relivant clause of PS.
Supply & laying cable XLPE insulated PVC sheathed, galvanised steel strip of wired armored. Electric power cable (heavy duty) 1100 V grade with stranderd aluminium conducter of size 25 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Material and labour for sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed. Note: Punned(consolidated) thickness of sand will bell be measured and paid.
Material and labour for cable protection with sub class 'B' bricks old size laid flat over sand cushioning of cable perpendicular across the cable in trenches complete all as specified and as directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
Supply and laid 50 mm GI light grade pipe for cable protection complete all as specified and directed.
M&L for road cutting for laying cable and through GI Pipe of suitable size making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as directed by Enger -in- charge.Note: GI pipe should be deemed to be included in the quoted rate.
Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32x6mm GI strip earthlead welded and riveted to earth plate at one end and connected to main switch / control switch of the building at another end GI earth strip encased in and including 40 mm dia GI light grade pipe and 20 mm dia GI 'meadium grade' pipe as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4type B-1 duly reinforced with MS TMT bars 8 mm dia @ 150 c/c both ways and with 10 mm dia MS bar in lifting handle , excavation , earth work including laying the GI pipe concealed in floor / wall all as described in electrical plate No 3 of MES SSR part-I
Supply and install hi wall split units indoor/outdoor complete INVERTER type with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity1.5 Ton all as apecified and directed by Engr-in-charge.Note-:1. The contractor should provide the necessary T&P for installation of AC. 2. The required length of copper tubing for suction and delivery upto 10 m deemed to be included in the quoted rate. 3. While installing AC the required pressure of refrigerent filled and checked by contractor without any extra cost. 4. The refrigerent of AC should be as per new enviromental guidlines as green gas.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit measured as one RM or one length. To connect near by MCB DB incoming and connect Sheet metal enclousre for AC connection.
Supply and fixing single pole and neutral enclosure with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA rupturing capacity 240 Volts AC complete all as specified & directed.
Supply and fixing 40-63 A amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning on exsiting near by DB
Supply and fix Voltage stabilizer for Air conditioner with automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
M/s badrinath Traders (BID ID -3097844)
TARUN ENGINEERING WORKS (BID ID -3081179)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .