| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-Finance | L1 | Accepted-Finance Please see Financial Evaluation sheet | |
| 2 | L2₹5.4 L+₹11,689.25 (2.22%)Accepted-Finance | L2 | Accepted-Finance Please see Financial Evaluation sheet | |
| 3 | L3₹5.6 L+₹31,660.80 (6.01%)Accepted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Accepted-Finance Please see Financial Evaluation sheet | |
| 4 | L4₹5.7 L+₹41,077.86 (7.80%)Accepted-Finance | L4 | Accepted-Finance Please see Financial Evaluation sheet | |
| 5 | L5₹5.9 L+₹68,028.11 (12.9%)Accepted-Finance MADHYAVEEDHI YELLAPUVANIPALEM VISAKHAPATNAM 530027 ANDHRA PRADESH INDIA | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L5 | Accepted-Finance Please see Financial Evaluation sheet |
Tender Value
Refer Docs
EMD Value
₹12,700
Closing Date
15 Jun 2022, 4:00 pmClosed
The Director
Directorate of Lighthouses and Lightships Deep Bhavan, Port Residential Area, Saligrampuram, Visakhapatnam - 530024
Electrification of New power house cum Office building at Santapalli Lighthouse
2022_DGLL_693268_1
MT-VSP-01002(01)/1/2020 Maint SNLH
Open Tender
Electrical Works
Works
90 days
Santapalli Lighthouse, Chintapalli (post)
EMD
11 documents required · 11 mandatory
₹0
₹12,700
Yes
Deep Bhavan Visakahpatnam
29 Jun 2022
7 Jun 2022
16 Jun 2022
7 Jun 2022
15 Jun 2022
7 Jun 2022
10 Jun 2022
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mm * 75mm) for Wall mounted fan
3 Module (100mm*75mm)
6 Module (200mm*75mm)
8 Module (125mmX125mm)
12 Module (200mm*150mm)
Supplying and fixing following modular switch/socket along with all the accessories required for installation on the existing modular plate & switch box including connections but excluding modular plate etc.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing PVC batten/ angle holder including connections etc. as required. (fancy type)
Supplying and fixing 3 pin, 5 A ceiling rose along with all the accessories required for installation on the existing junction box.
Supplying and fixing of minimum 25 mm size medium class PVC conduit in recess along with all the accessories (juction boxes,ceiling plates etc ) required for installation. Job includes cutting and plastering the wall, applying 1mm thick cement based putty and painting the wall.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing recessed PVC conduit along with all the accessories required for installation.
2 x 1.5 sq. mm(for lamp holder)
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door
Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and Commissioning etc. as commissioning etc. as required.
40 A Isolator 2 Pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A Isolator 2 Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A Single pole MCB
16 A Single pole MCB
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, Installation, testing and commissioning of following electrifical fittings (ceiling fan, including wiring the down rods of standard length (upto 30 cm), pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall) including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
4' 22W LED tube light fitting
LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb
25Watt LED street light fitting (Die cast powder coated enclosure with structured LED arrays and IP65/66 protectionand)
Single Phase Heavy Duty Exhaust Fan Dia 18 Inch 1400 RPM
Providing and fixing of street light bend pipe 1"(inch) GI class "C" pipe including clamp/SS screws etc.,
Ceiling Fan, Electro-phoretic lacquered/ Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation with Sweep 1200mm and Hight performance even at low voltage.
Two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying, laying of Bare Copper wire, 8 SWG in surface/ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (including all accessories like, clamp, screws etc., /tools)
Supplying and laying of the following one length Copper Armoured PVC insulated/PVC sheathed XLPE power cable ammended to IS 7098(Part 1) 1988 in ground. Job includes earth excavation, sand cushioning, protective covering with bricks and refilling the trench with excavated earth.
3 core X 4 sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Ph to outside gate light - 100 mtrs, PH to Inside street Light - 20 mtrs, PH to outside street light - 40 mtrs)
2 core X 6 sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Power house to IQ)
4 core X 16 sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Electric Pole to Power house)
2 core X 16 sqmm Copper un-armoured PVC insulated power cable as required. (Genset room o/p to AMF Panel)
3 core X 2.5sqmm submersible flat cable
3 core X 2.5sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Power house to LH tower bottom 40 meter for stair case & 40 meter for Main Light)
Laying of Various sqmm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade in the existing RCC road (including cutting and refilling) and GI 50 mm pipe as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required and Including clamped with 25x3mm GI flat clamp.
Electrification charge for installation of 15 KVA single phase Genset, AMF panel , Energy meter and pump house starter and termination of cable ends and connected in panel board. etc., including all accessories, tools, etc.,
Labour charge for making hole size of 600 mm in LH tower for cable inlet side (including all tools)
Labour charge for shifting of existing 15KVA single phase Genset from old power house to new power house including all accessories, tools, etc.,
Labour charge for shifting of existing 15 KVA single phase AMF Panel from old power house to new power house including all accessories, tools, etc.,
Labour charge for fixing PVC pipe, Junction box and fun hooks in slab during concrete of slab.
Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, 25mm PVC bends, tees, 1,2,3,4 way junction boxes,Cutting plates, 12 mm Fan SS hooks, Fan rod for extension, wire strippers, 1inch PVC insulation for copper strip(for neutral earthing), steel spring, pvc junctions boxes etc., Wall white putty and paints.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.(for power house) (1 No for Genset Body & Neutral Earthing) Lighthouse located at rocky area diffcult to digging earth pit (heavy duty machinary and labour charges) (plate earthing)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(for powerhouse Earthing) ((Lighthouse located at rocky area diffcult to digging earth pit (heavy duty machinary and labour charges))
Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required. (For Genset body & Neutral Earthing)
Supplying and fixing of aluminium checker plate size of 4 feet X 1 feet X 5mm thickness including cutting and fabrication etc.,
Supplying and fixing of 6 Inch PVC heavy pipe for cable inlet
Supplying and fixing 6 inch long bend
Energy meter shifting charge of APEPDCL
Providing and laying in position Cement Concrete in foundation bed with 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) All work up to plinth level including laying, compacting, curing as directed by the engineer in charge including cost of all materials, labours, tools & plants, curing, safety measures and all other charges etc., complete.
Providing of Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete, Suspended floors, roofs, landings, balconies and access platform, Columns, Pillars, Piers, Abutments, Posts and Struts and Stairs, including cost of all labour, materials, tools & plants ,safety measures and all other charges etc., complete.
Foundations, footings, bases of columns, etc. for mass concrete
20 mm thick cement plaster with CM 1:3 of brick masonry surfaces and Concrete surfaces for Eexterior plastering up to floor two level, including and finished even and smooth in CM 1 : 3.as per standard specification and as directed at site including supply of all material, labours, scaffolding, curing, tools & plants,safety measures and all other charges etc., complete.
Supply, Installation and testing of LT Distribution panel, Fabriated out of 16SWG CRCA Sheet not less than 2mm thick, powder coated, dust/vermin proof, compartmentalized with hinged doors, with one incomer and 3 outgoing with following single front, fixed type indoor installation type, Power Control Cubical Panel-with double bus bar system and Epoxy based powder coating of Colour Siemens Gray.(Wall Mounted) E.B INCOMER: Consisting of the following 1.100A,Kit-Kat Fuse Re-wirable type - 3 nos. 2.100A, Neutral Link - 1 no. 3.Main ON/OFF switch (SFU) HRC fuse 100AMPS. 4.Digital VAF(Multifuction) Meter along with necessary CT & PT. 5.R,Y,B Phase Indication Lamps (LED Type) 6.25kA, 4Pole, Surge Protector - 1 no. OUT-GOING FEEDERS: 1.63A,4Pole,10kA, MCB - 2 nos.
QUALITY ENGINEERING SERVICES
SRI SRK ENGINEERS
RADIANTTECHNOLOGIES
CH SUBBARAO AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .