Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.4 LAccepted-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹13.5 L+₹1.1 L (8.75%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L-2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Jan 2024, 6:00 pmClosed
GE (AF) Naliya No. 1
GE Air Force Station Naliya No 01
REPAIR REPLACEMENT OF INTERNAL WIRING FITTING AND FIXTURE AND CONNECTED EARTHING ITEMS AT DOMESTIC AREA AT AF STN NALIYA
2023_MES_632109_1
8934/E8
Open Tender
Electrical and Maintenance Works
Item Wise
270 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Naliya No. 1
₹30,000
Yes
19 Mar 2024
11 Dec 2023
10 Jan 2024
11 Dec 2023
8 Jan 2024
26 Dec 2023
Amount
Taking down copper/aluminum point wiring (light, fan, socket or power) complete and including fitting and fixture such as switches, socket,ceiling rose ,pendent ,regulators,light fittings etc complete all as specified and as directed. NOTE:- Job including for taking out old gutties, screw, nails, casing caping / conduit etc and making good to disturbed surface of wall ,floor etc including to match with the existing surface.
M&L for point wiring with 1.5 sqmm FRLSH single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor FRLSH as earth continuity conductor and connected to common earth dolly including PVC box ISI marked of suitable size for mounting the switches , socket outlets , fan regulators etc complete all as s specified and directed for the following :-
One light/Fan point controlled by one switch.
One socket 3 pin outlet 5 amp on independent board.
One light point controlled by two 2-way switches.
One 3 pin socket outlet 5 amp on the same board with other switches.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size
All as per item No 2 above but with copper conductor cable of 2.5Sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor complete all as specified and as directed.
S & F in replacment of switch piano flush type single pole one way 5 amp complete all as specified and as directed.
S & F in replacment of switch piano flush type single pole two way 5 amp complete all as specified and as directed.
S & F in replacment of ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified and as directed.
S&F in replacment of switch socket combination 2 in 1, 3 pin 5/15 amp flush type complete all as specified and as directed.
S&F switch socket combination 2 in 1.5 amp flush type complete all as specified and as directed.
S&F in replacment of socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type complete all as specified and as directed.
S&F in replacment of MCB DB SPN 8 ways double door horizontal type with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking out old DBs any type and cap and making good and match with the existing surface of wall complete all as specified and directed.
All as per item No 10 above but 4 way complete all as specified and as directed.
S&F in replacment of sheet metal enclosure vertical type 4 ways double door triple pole and neutral with 415 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified and directed
S&F in replacment of vertical type DB ,double door Suitable for isolated neutral bar 4 ways,IP 43 protection, Door earthing,mechenical impact strength IK 08 insulated busbar assembly,fixed in the wall with suitable nut and bolt including 4 pole MCCB 125 Amp 25KA fixed in DBs as incommer three phase supply fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall all as specified and directed
S&F in replacment of MCB TPN 100 amp complete all as specified and as directed.
S&F in replacment of MCB TPN 63 amp complete all as specified and as directed.
S&F in replacement of MCB single pole and neutral 32-63 amps, 240 Volts, Complete all as specified and directed.
S&F in replacement of MCB 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
S&F in replacement of switch bell push, flush type 5 Amp complete all as specified and as directed.
S&F in replacement of bell, AC, 230 Volts single pole complete all as specified and as directed.
S&F in replacement of lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified and directed.
S&F LED aluminium extruded housing batten light 01 Nos of LED 20-2500 lumens with efficacy of 125 LM/Watt fixed on two Nos of Square Block with twin core copper flexible wire and including taking down old type tube light fitting etc complete all as specified and as directed.
S&F LED aluminium extruded housing batten light 01 Nos of LED 10 Watt 100 LM/Watt fixed on two Nos of Square Block with twin core copper flexible wire and including taking down old type tube light fitting/holder any type etc complete all as specified and as directed.
S&F in replacement of energy efficient conventional LED Bulk head fitting 10 W IP 65 including twin core copper flexible wire and including taking down old type fitting/holder any type etc complete all as specified and as directed.
S&F in replacement of LED street light fitting 15 W with pressure die cast housing along with prismatic polymer carbonate diffuser and LED with secondry optic with IP 65 protection, including provision of GI pipe light grade of suitable size 40 mm and 1.5mtr long bent to the shape fixed in the wall with two nos of clamps,nut,bolts,screw etc and taking down old UNSV street light fitting any type complete all as specified and as directed.
S&F in replacement of fan regulator flush type on the existing phenolic laminated sheet etc as per requred complete all as specified and as directed.
S&F in replacement of LED Post top lantern warm white 45watt made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection, including provision of suitable size of GI pipe medium grade and suitable length as required on the site fifed on the existing pillers by welding of four Nos of leg and fixed by using fastner and nut and bolts and neccessary connection with suitable twin core copper cable multistranded 1100 volt grade, complete all as specified and as directed.
S&F in replacement of 9 Watt LED bolard in rectangular shaped victorian design with opal acrylic diffuser and IP 65 protection,including PCC work for mounting the fittings with suitable size of nut,bolts and connection with two core Copper cable 4sqmm complet all as specified and as directed.
S&F in replacement of 30W LED recessed 2x2 luminaire fixed in the existing Ciling/roofs white powder coated CRCA housing with LED seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size complete all as specified and as directed.
S&F in replacement sub main wiring drawing through and including PVC casing caping 32 mm size of size with all fittings two run of single core 6 sq mm FRLSH single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 6 sq mm FRLSH as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit and all accessories complete all as specified and as directed. Note: Three runs of cable, one run of casing & caping shall be measured as one unit.
S&F in replacement sub main wiring drawing through and including PVC casing caping of 32 mm size with all fittings two run of single core 4 sq mm FRLSH single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 4 sq mm FRLSH as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit and all accessories complete all as specified and as directed. Note: Three runs of cable, one run of casing & caping shall be measured as one unit.
M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
Checking and attending complaints by means of repairing/rectifying the electric defects/faults related to elctrical equipments,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : 1 The electrician deployed by the contractor shall have ITI /05 years expreince certificate in concerned trade.Helper deployed shall be min 8th pass with min 03 years expriance in relevant trade. 2. This item covers only cost of labour for attending complaint and taking down of old material. 3. Item to be replaced under this item shall be either isued free for fixing under schedule 'B'or shall be contractor supply under respective items of this schedule as decided by Enge-in -charge.Decision of GE in this regard shall be firm and binding. 4. Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail,failing which recovery of Rs.120/ per complaint shall be effected from the RARs/ F Bill. 5. Minor items as PVC wire of any size as per requirement up to 1.0m length,thimble,electric tape etc shall deemed to be included in the quoted rate of this items. 6.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be leived/imposed on the contractor and recovery shall be made from his dues. 7. Contracror shall arrange suitable T&P incl necessary means of transport, ladder and safety measures to make it functional complete all as specified and directed. 8. Contractor or his rep will report daily at complaint cell for collection of complaints fromthe concerned JE's incharge,in case after checking& attending the defects, if it is not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engeer in charge by the contractor/his rep immediately. If Engr -in -chargr is satisfied with contractor's view, no recovery will be made on this account. 9. Number of complaints attend at one location will be consider in one job only. i.e In each complaint for one location will be measured in one job only.
Supply only Switch socket combination 6/16 A 250V AC universal with box in polycarbonate complete all as specified and directed.
Supply only switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
Supply only socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
Supply only electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
Supply only capaciator 2.50 Mfd, 240 V complete all as specified and directed.
Supply only Hylem sheet 3 mm thick size 9'' x 11'' with suitable holes for switch,socket complete all as specified and as directed.
Supply only Hylem sheet 3 mm thick size 8'' x 5'' with suitable holes for switch,socket complete all as specified
Supply only of MCB TPN 100 amp
Supply only MCB TPN 63 amp
Supply only MCB single pole and neutral 35-63 amps, 240 Volts, Complete all as specified and directed.
Supply only MCB 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
Supply only switch bell push, flush type 5 Amp.
Supply only lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified & directed.
Supply only moduler switch 1 way 6A 1 module
Supply only moduler bell push 6 A, 1 module
Supply only moduler socket 6 A, 2/3 pin,2 module
Supply only moduler socket 6A/16A, 2/3 pin combined,2 module
Supply only moduler fan regulator 120 W. 2 module
Supply only moduler white cover plate with frame. 1 module
Supply only moduler white cover plate with frame. 2 module
Supply only moduler white cover plate with frame. 3 module
Supply only moduler white cover plate with frame. 4 module
Supply only moduler white cover plate with frame. 6 module
Supply only moduler white cover plate with frame. 8 module
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 200mmx150mmx50mm deep.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 350mmx300mmx50mm deep.
Supply only LED tube 18/20 watt
S&F in repair of aesthetically designed LED security light luminiareis of 35 watts system wattage for energy saving having IP 66 degree of protection,with minimum system efficiency as>85%,made of pressure die casting aluminum housing power coated in graphite grey and heat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light Fitting should have operating voltage range of 120-270 VAC,THD<10%,P.F>.95 The fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including 40mm dia GI pipe light grade of 1.5mtr length with necessary clamp & nut bolts complete all as specified and directed.
KALIKAY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .