Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.7 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹16.7 L+₹1.1 L (6.82%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L-3₹16.9 L+₹1.2 L (7.64%)Rejected-Finance PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L-3 | Rejected-Finance Other than Lowest Bidder |
| Sl No | Description | Qty | Unit | AARTI ENTERPRISES L1 | Krishna Engineering L2 | JYOTI TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and fix in replacement Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool complete all as specified and directed. | 1 | EACH | 21,600 ₹21,600 | 22,000 ₹22,000 | 21,500 ₹21,500 Lowest |
| 2.00 | Supply and fix in replacement Air release valve complete assembly suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool complete all as specified and directed. | 1 | EACH | 11,850 ₹11,850 Lowest | 12,500 ₹12,500 | 13,000 ₹13,000 |
| 3.00 | Supply and fix in repairs V-belts, type A-23 model suitable for CSU motors for AC plant complete all as specified and directed.
Make: Fenner/ Dunlop or equivalent | 300 | EACH | 250 ₹75,000 Lowest | 320 ₹96,000 | 300 ₹90,000 |
| 4.00 | Supply and fix in repairs V-belts, type B-62 model suitable for AHU motors for AC plant complete all as specified and directed.
Make: Fenner/ Dunlop or equivalent | 36 | EACH | 550 ₹19,800 Lowest | 600 ₹21,600 | 590 ₹21,240 |
| 5.00 | Supply and fix in repairs V-belts, type A-44 model suitable for AHU motors for AC plant
Make: Fenner/ Dunlop or equivalent | 25 | EACH | 350 ₹8,750 Lowest | 430 ₹10,750 | 450 ₹11,250 |
| 6.00 | Material and labour for top up/ gas charging with refrigerant gas (R-410) for dehumidifier after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and directed. | 10 | KILOGRAM | 1,940 ₹19,400 Lowest | 2,450 ₹24,500 | 2,500 ₹25,000 |
| 7.00 | Supply and fix in replacement rotary / invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and directed | 2 | EACH | 12,000 ₹24,000 Lowest | 12,500 ₹25,000 | 12,300 ₹24,600 |
| 8.00 | Running/running capacitor of 35 MFD for dehumidifier complete all as specified and directed. | 8 | EACH | 535 ₹4,280 Lowest | 600 ₹4,800 | 580 ₹4,640 |
| 9.00 | Blower motor of dehumidifier FDNF96, 2 KG, 230V, 50Hz complete all as specified and directed. | 2 | EACH | 3,120 ₹6,240 Lowest | 3,500 ₹7,000 | 3,600 ₹7,200 |
| 10.00 | Fan blade for blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz complete all as specified and directed. | 3 | EACH | 720 ₹2,160 Lowest | 800 ₹2,400 | 900 ₹2,700 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER, AIR FORCE STATION NALIYA NO. 1
GE AIR FORCE STATION NALIYA NO 01
REPAIR AND MAINTENANCE OF CASSET AC/CSUS, MOTORS AND ASSOCIATED ITEMS AT 2403 SQN INSIDE TECHNICAL AREA AT AF STN NALIYA
2025_MES_697086_3
8029/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) Naliya No. 1
₹30,000
Yes
27 Aug 2025
15 May 2025
9 Jun 2025
15 May 2025
5 Jun 2025
22 May 2025
Amount
Supply and fix in replacement Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool complete all as specified and directed.
Supply and fix in replacement Air release valve complete assembly suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool complete all as specified and directed.
Supply and fix in repairs V-belts, type A-23 model suitable for CSU motors for AC plant complete all as specified and directed. Make: Fenner/ Dunlop or equivalent
Supply and fix in repairs V-belts, type B-62 model suitable for AHU motors for AC plant complete all as specified and directed. Make: Fenner/ Dunlop or equivalent
Supply and fix in repairs V-belts, type A-44 model suitable for AHU motors for AC plant Make: Fenner/ Dunlop or equivalent
Material and labour for top up/ gas charging with refrigerant gas (R-410) for dehumidifier after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and directed.
Supply and fix in replacement rotary / invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and directed
Running/running capacitor of 35 MFD for dehumidifier complete all as specified and directed.
Blower motor of dehumidifier FDNF96, 2 KG, 230V, 50Hz complete all as specified and directed.
Fan blade for blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz complete all as specified and directed.
Material and labour for servicing, greasing and alignment of AHU/CSU motors and pullies installed at AF Stn Naliya complete all as specified and directed.
Repairs , servicing , cleaning and descaling with the help of diluted Acid of heat exchanger for hot water & cold water installed in CSU (Ceiling suspended unit) of 3TR capacity including minor repair and parts as nut bolt brazing/welding etc for any leakage observed complete all as specified and as directed.
Repair / servicing, descaling and cleaning of Hot Water Generator 45KW capacity 3 pase 440 Volts 50Hz including minor parts as two qty heating coil /nut bolt/packing etc complete all as specified and directed.
Supply and fix in replacement to CSU monoblock pump set of capacity 0.25 HP, single phase 230 Volts complete all as specified and directed. Make Crompton/Kriloskar/ABB
Supply and fix in replacement of 12V 26 AH maintenance free batteries for power backup of UPS unit complete all as specified and directed. Make: Exide/Amtrex/Amaron
Supply and fix in replacement of 12V 7 AH maintenance free (SMF) batteries for power backup of UPS unit complete all as specified and directed. Make: : Exide/Amtrex/Amaron
Supply and fix in replacement of Spun Filter /Cartridge of RO Plant complete all as specified and directed.
Material and labour for Anti scalant suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica complete all as specified and directed.
Supply and fix in replacement of high TDS Membrane of RO Plant of size up to 40/40 complete all as specified and directed. Make-Filmtec or equivalent
Supply and fix in replacement of 25 mm Aggrigate for RO plant of any capacity complete all as specified and directed.
Supply and fix in replacement of 10 mm Aggrigate for RO plant of any capacity complete all as specified and directed.
Supply and fix in replacement of silica sand from Sand filter for RO plant of any capacity complete all as specified and directed.
Supply and fix in replacement of Activated Carbon from carbon filter for RO plant complete all as specified and directed.
Dismantling the components of Reverse Osmosis plant and checking the serviceability of plant including rubber bushes, fittings, low pressure/ high pressure motor pumps & Cleaning of membrane filter with citric acid and cleaning, washing with the help of high pressure water pump complete and re-fixing the same after necessary repairs and replacement of unserviceable parts, commissioning and testing complete all as specified and as directed by EIC. Notes:- Replacement of defective items of existing make/ size shall be measured and paid separately under respective items.
Supply and fix in replacement of EWT (Entering water temperature) of 13x3 or 12x3 TR chiller plant sensor as per existing model complete all as specified and as directed.
Supply and fix in replacement LWT(Leaving water Temperature) of 13x3 or 12x3 TR chiller Plantsensor as per existing model complete all as specified and as directed.
Material and labour for removing of damaged portion of duct insulation and fixing new Nitrile Insulation 13 mm (minium) thick closed cell elastomeric nitrile rubber insulation of 40-60 kg/cum density, on duct surface free from dust etc using a thin film of insulation material all as per manufacturer's recommended adhesive. Both duct and instulation, keeping the insulation material under compression (without any stretching), seal all joints air tight etc complete all as specified and as directed. Make:- Aramacell/ A Flex/ Armaflex/ K Flex as approved by GE.
Supply and fix in replacement 100 mm dia butterfly valve of AC chillier plant circulation pipe line, of existing model, welding the same as per existing fixing arrangements complete all as specified and as directed.
Supply Installation testing & commissioning of Humidifier controller for atuomation complete all as specified and directed.
Supply Installation testing & commissioning of Heater strip 2/4KW capacity complete all as specified and directed.
Supply of Thermostate for humidifier complete all as specified and directed.
Supply and fix in replacement of 40 TR capacity Cooling Tower PVC filings along with sprinkler set, tension bar GI material,turn buckle, branch pipe of suitable size(approx 50 mm dia) and FRP eliminator blades for each cooling tower complete all as specified and directed.
Supply and fix in repair to cooling tower blower induction motor of capacity 5 HP/3.7KW, three phase 440 Volts with rewinding of motors with suitable size of super enamelled copper wire including shaft bearing including taking down, transportation to maintenance work shop, refixing complete all as specified and directed. Make-Kirloskar, Type-KDI-527++.
Supply and fix power contactor 3 pase system for 1.5 HP motor installed at TP-III including 10 Amps relay & PLA relay of blower motor Motor complete all as specified and directed. Make - Make-L&T( Model No MNXA1 & MXA1) or equivalent
Supply and fix power contactor for single phase motor of capacity 0.25 HP installed at TP-III complete all as specified and directed. Make : Schnieder (Model No-LAEN22 ) or equivalent
Material and labour for opening of CSU(Ceiling suspended unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new shaft,new pully and bearings (02 Nos) for 3 TR Capacity CSU including testing and greasing complete all as specified and directed.
Material and labour for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 25 TR Capacity AHU including testing and greasing complete all as specified and as directed.
Material and labour for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02 Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 35 TR Capacity AHU including testing and greasing complete all as specified and directed.
Material and labour for FRP coating inside CSU area for arresting any type of water leakage in side CSU complete all as specified and directed.
Supply and fix in replacement of cooling tower water inlet float Float valve PVC type complete all as specified and directed.
Supply and fix metal based Float valve for Humidifier of capacity 2KW to 10 KW complete all as specified and directed.
Supply and fix Cooling Tower Fan blade suitable for 40 TR capacity cooling tower complete all as specified and directed.
Repair / servicing of stuck monoblock motor and pump set of 0.25 HP capacity single pase 440 Volts 50Hz lubricate the motor bearings after clean the rust with help of anti scale spray and tight the all nut bolt/packing etc complete all as specified and directed.
Supply and fix in repair to UPS of 600VA capacity of output 230 V, 50 Hz for BMS system complete all as specified and directed.
Supply and fix in repair to UPS of 1000VA capacity of output 230 V, 50 Hz for BMS system complete all as specified and directed..
Supply and fix in repair to UPS of 3000VA capacity of output 230 V, 50 Hz for BMS system complete all as specified and directed.
Supply and fix in repair of HRC Fuse link set of 03 of 400 Amp 3NA3 260-7Y, NH2, 500V~/120ka IS-13703 IEC 269-2 complete all as specified and directed.
Dismantling and taking out monoblock motor of 0.25 HP to 2 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as specified and directed.
Replacement of bearing of motor DE side complete all as specified and directed.
Replacement of bearing of NDE side complete all as specified and directed.
Dismantling and taking out monoblock motor of 3 HP to 7.5 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc.complete all as specified and directed.
Replacement of bearing of motor DE side complete all as specified and directed.
Replacement of bearing of NDE side complete all as specified and directed.
Dismantling and taking out monoblock motor of 10 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as specified and directed.
Replacement of bearing of motor DE side complete all as specified and directed.
Replacement of bearing of NDE side complete all as specified and directed.
Dismantling and taking out monoblock motor of 20 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc.complete all as specified and directed.
Replacement of bearing of motor DE side complete all as specified and directed.
Replacement of bearing of NDE side complete all as specified and directed.
Supply and fix of suitable size of super enamelled copper wire for winding of motors complete all as specified and directed.
Supply and fix Air Break DOL Starter of 6-10 Amp, testing and commisioning complete all as specified and directed.
Krishna Engineering (BID ID -3308482)
JYOTI TRADERS (BID ID -3307612)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .