Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹29.6 L+₹64,630 (2.23%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹32.2 L+₹3.2 L (11.0%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.2 L+₹3.2 L (11.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹32.4 L+₹3.4 L (11.8%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹29.7 L
EMD Value
₹59,320
Closing Date
25 Apr 2020, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA No CWE/HILLS/PGH/04 of 2020-21 OUTSOURCING OF E/M INSTALLATION (33 KV SB STATION) AND CONNECTED AREA MISC ELECTRICAL WORK AT PITHORAGARH UNDER GE (MES) PITHORAGARH
2020_MES_337371_1
CA No CWE/HILLS/PGH/04 of 2020-21
Open Tender
Electrical Maintenance Service
Works
330 days
PITHORAGARH
CLASS D
10 documents required · 10 mandatory
₹500
Yes
GE PITHORAGARH
₹59,320
Yes
22 May 2020
3 Apr 2020
27 Apr 2020
3 Apr 2020
25 Apr 2020
18 Apr 2020
4 Apr 2020 - 17 Apr 2020
Amount
Providing services for smooth functioning of 33/ 11 KV MRS at Pithoragarh Cantt having 10 MVA capacity 33/11 KV transformer comprising of 33 KV steel structures with bus bars, insulators, AB switches, transformer 5000 KVA - 02 Nos. of 33/11, 63 KVA(33/0.433) - 01 No battery bank & battery charger, 33 KV HT panel boards, 11 KV VCB breakers, 33 KV outdoor structure, PT's metering system bus couplers, HT/LT cables, control cables, LT panel boards for substation lighting & lighting, earthing pits of all the equipments (including regular watering) & plants, carrying out regular testing (Routine test / type test of transformer, earth test of all substations HT/LT equipments) of the equipments and maintaining of the earth testing register / insulation testing register / Oil testing registers, shut down register / visual check register etc, Log sheet with Duty Roaster / attendance register records of the electric supply with all parameters as described at the substation and daily maintenance of the complete surrounding area of the MRS. As when Supply fails/ restore from UPCL or breakdown is informed to the MRS in charge within 05 Minutes of breakdown, complete all as specified and directed by the Engr-in-Charge. NOTE :-(i) The job shall be maintained by deploying 03 Nos. Skilled Electricians and 03 Nos. Mate Electricians in three shifts (including Sunday and holiday) as given below :- (a) First shift 0600 hrs to 1400 hrs (b) Second shift 1400 hrs to 2200 hrs (c) Third shift 2200 hrs to 0600 hrs (ii) Quoted rate shall be deemed to inclusive of leave/ reserve / off of the tradesmen employed as per labour laws. (iii) Quoted rate shall be deemed to inclusive of normal maintenance i.e oiling, greasing, tightening of conductors, tightening of HT/LT cable joints of all equipments installed at receiving centre, restoration of jumpers, HT fuses by means of using existing resources during short circuits due to wind / rains without any extra cost of material to the department within premises of MRS and to restore the supply for incoming and outgoing feeders. (iv) Maintaining of log sheet of 33 KV VCBs and 11 KV VCBs (Log sheet shall be provided by the contractor at his own cost shall be done by the electrician employed. (v) Keeping record of maintenance, checking earth resistance of all equipments and regular watering of earth pits shall be done by the electrician employed. (vi) Keeping record of shut down / break downs shall be responsibility of tradesmen deployed at MRS shall be done by the electrician employed. (vii) Reliver duty Electrician & Mate Electrician wages deemed to be included in quoted rates. (viii) All T&P for testing at MRS to be provided by the contractor and no extra cost to be paid to the contractor for T&P. (ix) Electrician employed should be holding ITI certificate with minimum 4 years experience (x) The contractor shall be responsible for safety, security, cleaning and upkeep of installation as per MES standards for installation. (xi) The contractor shall provide first aid box / kit and all safety equipments like discharge rod, safety belt, hand gloves, helmet, glasses, rain coat, gum boot etc in the installations and rates are deemed to be included in quoted rates.(xii) Electrician / mate electrician on duty should be in proper dress as approved by the GE.
Outsourcing for manning & operation for smooth functioning of HT/LT Electric distribution system for proper distribution of electric supply at the different locations at Cantt area to carrying out regular checks and services to the HT/LT feeders, HT/LT overhead lines and rectification any fault occurred in the feeder like disconnection of jumpers, breaking of ACSR conductor, GI wire, disconnection of cable lugs from the panel / transformer, blown out of fuse element, fallen of tree branches, tripping of feeders and loose connection in the service wire / cable, short circuiting of conductors, fixing of HT joints any type and attending of complaints for no lights from poles and other type of faults in HT/LT feeders all transformer, ACB, LT panel except MRS, up keep of 11 KV Sub Station and ensure serviceability of all the equipments, watering in earth pits of transformer, including undertaking routine maintenance / checks, replacement of fuses on two / four pole structure, maintenance of 11/.433 KV transformers, maintenance of surrounding area of the sub stations, checking of electrical control panel and through cleaning of equipment / machinery on all the days including Sundays and holidays in two shift of schedule as given below complete all as specified and directed by Engr-in-charge:- (i) First shift 0600 hrs to 1400 hrs by deploying 01 skilled electrician + 02 Nos Mate Electrician (ii) Second shift 1400 hrs to 2200 hrs by deploying 02 Nos. Mate Electrician. NOTE:- (a) The cost of minor part such as nut & bolts, washers, rubber gasket etc is deemed to be included in quoted rates. (b) Reliver duty Mate Electrician wages deemed to be included in quoted rates. (c) Spare parts shall be measured and paid separately under respective items of BOQ. Note for item no. 1 & 2 :- (i) In case of requirement, tradesmen provided for one area may be utilised in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (ii) Tools & plants shall be provided by contractor. (iii) Temporary laying only of LT underground cable of any size and any length for restoration of electric supply during break down / other requirement deemed to be included in the above quoted rate. (iv) Complaint register and Complaints slip books as per site requirement shall be provided by the contractor at his own cost. (v) Departmental equipments of each installation shall be under safe custody of the contractor. (vi) Group insurance & EPF for the electrician & Mate electrician shall be made by the contractor at his own cost and documentary proof shall be submitted to Engr-in-Charge. (vii) All T&P as required, shall be provided by the contractor at his own cost. (viii) Proper handing / taking over of inventories of all installations shall be kept in record.
Supply only jumper wire cross sectional area 50 Sqmm single core stranded aluminium conductor, PVC insulated on OH lines, complete all as directed.
Supply only jumper wire cross sectional area 70 Sqmm single core stranded aluminium conductor, PVC insulated on OH lines, complete all as directed.
Supply only jumper wire cross sectional area 95 Sqmm single core stranded aluminium conductor, PVC insulated on OH lines, complete all as directed.
Supply only insulator pin type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height and 65 mm dia suitable for working pressure 1100 Volts grade, complete all as specified and directed.
Supply only insulator shakle type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 75 mm height and 90 mm dia suitable for working pressure 1100 Volts grade, complete all as specified and directed.
Supply only pin type porcelain , vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height and 150 mm dia suitable for working pressure 11000 Volts grade complete all as specified and directed.
Supply only disc type insulator, poprcelain, vitreous in single disc assy for tension with tension clamps for conductors, working pressure 11000 volts of size 145 mm high and 255 mm dia ball complete all as specified and directed.
Supply only galvanised iron 8 SWG (4mm dia) continuous bearer wire (earth wire) on steel poles including binding wire of suitable size, complete all as specified and directed.
Supply only ACSR conductor of any type, any size, complete all as specified and directed.
Supply only 1100 volt grade, heavy duty 16 Sqmm cable, PVC insulated aluminium conductor served with inner sheathing or PVC tape and overall PVC sheathed in service connection of in jumper wire for one twin core cable flat with stranded aluminum conductor, complete all as specified and directed.
Supply only 1100 volt grade, heavy duty 10 Sqmm cable, PVC insulated aluminium conductor served with inner sheathing or PVC tape and overall PVC sheathed in service connection of in jumper wire for one twin core cable flat with stranded aluminum conductor, complete all as specified and directed.
Supply only 1100 volt grade, heavy duty 6 Sqmm cable, PVC insulated aluminium conductor served with inner sheathing or PVC tape and overall PVC sheathed in service connection of in jumper wire for one twin core cable flat with solid aluminum conductor, complete all as specified and directed.
Supply only 1100 volt grade, heavy duty 2.5 Sqmm cable, PVC insulated aluminium conductor served with inner sheathing or PVC tape and overall PVC sheathed in service connection of in jumper wire for one twin core cable flat with solid aluminum conductor, complete all as specified and directed.
Supply only cable end box (Heat shrinkable) out door type HT 11000 volts grade suitable for XLPE 11000 Volts grade screened armored cable of size 50 Sqmm to 95 Sqmm, 3 core, heat shrinkable connected with electric system, complete all as specified and directed. Make :- REYCHEM/ DENSON/ M SEAL
Supply only cable end box (Heat shrinkable) out door type HT 11000 volts grade suitable for XLPE 11000 Volts grade screened armored cable of size 120 Sqmm to 185 Sqmm, 3 core, heat shrinkable connected with electric system, complete all as specified and directed. Make :- REYCHEM/ DENSON/ M SEAL
Supply only cable end box (Heat shrinkable), straight through type HT 11000 volts grade suitable for XLPE 11000 Volts grade screened armored cable of size 120 Sqmm to 185 Sqmm, 3 core, heat shrinkable connected with electric system, complete all as specified and directed. Make :- REYCHEM/ DENSON/ M SEAL
Supply only HT tape roll 3/4 inch size, ISI marked, complete all as directed.
Supply only LT tape roll 3/4 inch size, ISI marked, complete all as directed.
Supply only fuse wire 5 Amps to 100 Amps as directed by Engr-in-Charge.
Supply only lugs / connectors of size 16 Sqmm, complete all as directed.
Supply only lugs / connectors of size 25 Sqmm, complete all as directed.
Supply only lugs / connectors of size 35 Sqmm, complete all as directed.
Supply only lugs / connectors of size 50 Sqmm, complete all as directed.
Supply only lugs / connectors of size 70 Sqmm, complete all as directed.
Supply only lugs / connectors of size 95 Sqmm, complete all as directed.
Supply only lugs / connectors of size 120 Sqmm, complete all as directed.
Supply only lugs / connectors of size 150 Sqmm, complete all as directed.
Supply only lugs / connectors of size 185 Sqmm, complete all as directed.
Supply only lugs / connectors of size 240 Sqmm, complete all as directed.
Supply only PG clamp suitable for dog /weasel / ferret / squirrel conductor, complete all as directed.
Lopping / pruning of tree branches uo to the extend to obtain clearance all around the LT over head lines / HT over head lines conductor up to 3.00 m from furthest conductor on pole including removing of cut branches and cleaning of site, complete all as directed by Engr-in-Charge. Note :- (i) The tree's branch etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (ii) Pruning of all tree branches in one tree shall be measured as one job. (iii) The contractor will employ sufficient labour (Not from item no. 01 & 02) to complete the job with in time as directed. (iv) The contractor will be responsible for any type of mis-happening / accident while pruning the trees. (v) The contractor will take proper shut down from MES installation before starting the work and clear it before resuming power supply. However full assistance will be provided by MES staff for shut down / resuming supply. (vi) The contractor will provide proper tools and safety devices to his staff for pruning of trees
Amit Engineering
SANJEEV ENTERPRISES
URBANS CONSTRUCTIONS
shahji contractors
Ishtiaq and Sons
M/s J P Traders
M/S Shahjee Fridge Service
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .