| 1 | L1₹47.4 LAccepted-AOC 0 NEAR SATYANARAYAN SOCIETY GAYATRI MANDIR ROAD 0 BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹49.2 L+₹1.8 L (3.76%)Rejected-Finance BHUJ NAKHTRANA HIGHWAY ROAD AT POST SHUKPAR NAVAVAS BHUJ KUTCHH 370040 GUJ | KACHCHH | GUJARAT | 370040 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹51.7 L+₹4.3 L (9.06%)Rejected-Finance GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT
PROVISION OF CERTAIN CAP/MR/MW WORKS UNDER AGE BR-(I) (II) AND AGE (E/M) AT AF STATION BHUJ
2021_MES_484437_2
8888/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BHUJ
₹94,800
Yes
8 Mar 2022
27 Nov 2021
29 Dec 2021
27 Nov 2021
27 Dec 2021
4 Dec 2021
60 days
Amount
Material & labor for Chemical earthing complete with copper plate electrode (98 percent conductivity when annealed)of size 90 cm x 60cm x 5 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including copper strip(98 percent conductivity when annealed) 32 x 6 mm upto 7.5 mtr long by means of means of copper/brass bolt, nut, check nuts and washers besides brazing at all joints with GI protection pipe of 40mm bore medium grade up to 7.5 metre and connected to earthing test point all as shown in electrical plate No.3 of SSR part-I and as specified or indicated and testing on completion including excavation & eartwork in any type of soil, PCC (1:3:6) type C-2 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4 Kg/Sqm), with frame, funnel with 20mm bore GI pipe medium grade watering pipe, wire mesh and lugs test point etc including 150 mm of magnesium sulphate above the top layer of salt and spreading evenly all round the plate and filling remaining with vegetable soil upto PCC chamber bottom and testing on all as directed NOTE: On testing, after completion, if the earth resitance less than desired is not obtained, earthing will be regenerated at no extra coas till the desired earth resistance is obtained.
S&F copper strip 32 x 6 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing, with PVC insulation to prevent touch with ground etc all as specified and as directed by Engineer-in-charge.
S&F test point terminal block made of gun metal / phosphorus bronze/copper of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.
Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in trenches, under road/ foot path and making good of size 25 mm bore complete all as specified and directed.
Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in trenches, under road/ foot path and making good of size 15 mm bore complete all as specified and directed.
Suplly and fixed Gun matal gate valve with iron wheel head, screwed both ends iron pipe and fixed size 25 mm dia.
Cutting the existing steel tubing GI line of 25 mm bore inserting Tee including excavation earth work all as directed.
S&F bib tap standard for 15 mm bore of PTMT any colour screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
M & L for one light point/ fan point controlled by one, one way flame proof switch surface type wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through ERW steel conduit heavy duty ISI mark of size 20mm external dia with all accessories like tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles, pipe hooks etc as specified
Supply and fix Flame proof rotary type switch with termination box in LM6, 16A single pole 250V.
S & F flame proof and weather proof FLP LED flood light fitting 90 watt system effiency not less than 122 lumen watt Cat No 1251 of Make :Shyam Switchgears Ltd or equivalent in Sudhir Switchgears Ltd/Balinga.. complete all as directed and specified.
Excavating over areas, n exc 1.5 m deep and getting out in soft /loose soil complete all as specified and directed.
Removing soil excavation materials exceeding 500 m but not exceeding 1.5 km and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Material and labour for cement concrete 1:3:6 type C-1 (using 40mm graded stone aggregates) as in foundation, surface channel filling, coping and mass concrete complete
Material & labour for rendering 10 mm thick in CM 1:4 on brick works, concrete or similar surfaces finished surfaces even and smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/loose soil complete.
Removing soil excavation materials not exceeding 100 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for reinforced concrete pipe,class NP-3, 600 mm bore pipe, laid and jointed complete with collars, jointed with cement mortar (1:1) all as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil . etc all as specified and directed complete.
M&L for concrete bedding in 1:3:6 type C2 to drain pipes including packing under and haunching completely surrounding of pipes after they are laid and tested of size 600 mm RCC pipe.
M&L for hardcore broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layer not exceeding 15 cm thick, watered and rammed to a true surface complete.
M&L for premix bituminous macadam 75mm thick consolidated thickness using 4% binder content by weight of total mix using paving bitumenof grade VG-30, laid/rolled and compacted to required gradient and camber all as specified and directed.
M&L for bituminous premixed semi dense asphaltic concrete of 40 mm consolidated thickness of grade VG-30 with 6.0% binder content by weight of total mix to be laid with mechanical power, rolled and compacted to required camber and gradient with 8 to 12 tonne capacity power roller all as specified and directed by Engineer in Charge.
M&L for Precast cement concrete block masonary with solid blocks exc 10cm in width (1:5:8) 20mm graded aggregate and setting in cement mortar 1:6 all as specified and directed
M&L 150 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate in floor finished surfaces even and smooth without using extra cement complete all as specified and directed.
Forming dummy joints 65 mm deep X 10 mm wide filled with sealing compound grade 'B' all as directed by Engr-in charge
Taking down chowkats or frames with shutters (without taking off shutters from frames) size n. exc 1.5 sq mtr each
Taking down chowkats or frames with shutters (without taking off shutters from frames) size exc 1.5 Sqm & n.exc 4.00 Sqm each.
M&L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L for anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
M&L for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
M&L for providing precast reinforced cement concrete type A1, 1:1.5:3 using 20mm graded aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork and demolition / taking up of existing cover slabs & removing rubbish outside MD land. Note : S&F reinforcement shall be measured and paid separately.
M & L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality.
S& F framed work Fe 410 -W (Gde- E- 250) quality A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5mm FRLS PVC insulated unsheathed copper earth wire including Suitable for switches and sockets complete all as specified and directed by Engineer-in-Charge.
(a) One light point controlled by one, one way switch single pole
(b) One Fan point controlled by one, one way switch single pole.
(c) One 3 pin 5 Amp socket outlet on same board .
All as per item No.38.00 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board.
Supply and Fixing wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells or equivalent in Orient/Philips/Bajaj/CG/Surya/Polycab all as directed by EIC.
Supply and fix energy saving ceilling fan 1200mm sweep, colour- Ivory, connecting up including provision of cable from ceilling rose or connector to fan all as specified and directed by Engr-in-charge .Make :Havells or equivalent Bajaj/ Crompton Greaves/Usha.
Supply and Fix metal body exhaust fan, heavy duty AC single phase 230/240V of size 300 mm sweep 1400 RPM complete all as specified & directed by Engineer-in-Charge. Make:Havells or Equivalent in Bajaj//CG/Usha. Note:-The rate quoted shall be in including 4 nos of stainless steel fastner of suitable size to fit the exhaust fan and suitable ventillation jali (net) made with stainless steel for covering the hole from ouside , and no extra payment will be allowed to contractor on this regard.
S&F switch socket outlet, 2 in 1, 5 Amp, flush type all as directed/ specified.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal type all as directed/ specified.
S&F switch piano type, 5 Amp. SP, one way all as directed/ specified.
S&F ceiling rose surface bakelite 65mm x 50mm three terminal all as specified and directed
S&F stepped type electronic fan Regulator flush type on the existing phenolic laminated etc as reqd single pole 240 volts grade 350 watts heavy duty ISI marked.
S&F double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coated all as specified (Make : Havell's, L&T, Standard, Crompton/Indoasian/Polycab)
S&F MCB/Isolator SPN of 240 Volts 63 Amp capacity, 'C' series, 10 KA in the existing distribution board (Make : Havell's, L&T, Standard, Crompton/Indoasian/legrand)
S&F MCB/Isolator SPN of 240 Volts 32 Amp capacity, 'C' series, 10 KA in the existing distribution board (Make : Havell's, L&T, Standard, Crompton/Indoasian/legrand)
S&F MCB/Isolator SP of 240 Volts 20 Amp capacity, 'C' series, 10 KA in the existing distribution board (Make : Havell's, L&T, Standard, Crompton/Indoasian/legrand)
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply and install air cooed split unit Air Conditioners electric driven single Phase of capacity of 1.5 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating EER 3.2.
S&F Voltage stabilizer Electronic wall mounting type suitable for AC upto 1.5 TR for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 260 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 4.0 KVA
S&F metal clad enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through PVC Conduit and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note: Two runs of conductor with one run of earth wire will be measured & paid as one unit)
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 25 sqmm, 4.0 core complete all as specified and directed
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed.
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm all as specified and directed.
Removing soil excavation materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
S & F of tubes light grade of 40 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts complete all as specified and directed by EIC.
S&F MCCB four pole 63 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required. Make - Havells or equivalent in C&S/Schneider or Hager as approved.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete.
M&L plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete,all as specified
Material & labour for RCC M-30 (Design mix) with 20mm graded stone aggregates for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc all as specified and directed.
M&L for reinforced cement concrete M-30 (Design mix) using 20mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cills and in shelves and the like complete all as specified.
Material & labour for RCC M-30 (Design mix) with 20mm graded stone aggregates for Columns, pillars, piers,posts and struts etc all as specified and directed.
Material & labour for RCC M-30 (Design mix) with 20mm graded stone aggregates for chajjas all as specified and directed.
M&L for formwork to sides and soffits of suspended slabs such as roof slab, floor slabs landing horizontal or slopping and similar works thickness n.exc 200mm including necessary sufficient supports as directed by Engr-in-Charge etc for flat and rough finished surfaces of concrete etc complete.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar works vertical or to batter flat rough finished.
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia for links , stirrups, spacers and binders and binding with and including mild steel wire not. less than .9mm dia or securing with clips complete.
Material & labour for rendering 10 mm thick in CM 1:6 on brick works, concrete or similar surfaces finished surfaces even and smooth without using extra cement complete all as specified and directed.
Material & labour for rendering 15 mm thick in CM 1:4 on brick works, concrete or similar surfaces finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 concrete surface in ceiling etc. finishing the surfaces even on smooth without using extra cement all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) superior quality area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for 50 mm thick PCC 1:3:6 ,type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection all as specified and directed.
M&L preparation of new plastered surface on ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of Birla White Putty by finishing the surfaces even and smooth complete all as specified and directed by EIC.
M&L for preparation new plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and as directed using Nerolec surksha / Asian ACE / Berger Walmasta
S&F 35 mm thick 2nd class hard wood plain framed panelled shutter (two panells) with lock rail and pannel of 9mm BWP commericial ply or 12mm veneered particle board with commericial veenering on both faces. The size of rail and style as per IS: 1003 (part I). Kiln seasoned and chemically pressure treated complete.
M&L for aluminium window with double side hung shutter for glazing and gauging and frame with one or more rebates made out of JINDAL/ INDAL anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle and anodised aluminum fittings such as stay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) all as specified and directed.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under above item shall be measured and paid separately. Note : main section of aluminium shall be used 100mmx45MM with same thickness as mentioned in lieu of drg 65mm x 38mm above reffered due to less space available for fixing wire gauge shutter fixing grill
Supply only aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mm made out of standard aluminium moulded section of size 4.4 mm x 7mm
Supply , fabricate & fix anodised (15 micron) aluminium sliding windows/ ventilators made out of Jindal/Hindalco Aluminium sections as in frames , sliding/ fixed shutters etc. With one or more rebates incl. Jointing cleats & locking arrangements complete all as specified & as per manufacturer's instruction. Note- Quoted rate shall deemed to be included for supply of aluminium sections, fabricate & fixing in position of window frames & shutters, locking arrangements complete.
S&F rubber beading for fixing of glass complete.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete.
S & F 300 mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate including taking down old sliding door bolt all as specified and as directed.
S&F 150 mm size mild steel pressed handles, oval type, stove enamelled black complete.
S&F 100mm size butt hinges, medium weight, cold rolled mild steel complete.
S&F 110 mm bore PVC (SWR) pipes, single socket in any length with rubber ring joints fixed as in floor or laid in trenches complete.
S&F in repairs for 110 mm bore PVC (SWR) bends in any radius complete
M&L for applying cold bituminous primer @ 0.30 Ltr / Sqm conforming to IS 3384 laying APP polymer modified membrane 3.6 to 4.0 Kg/Sqm in weight with non-woven polyster reinforcement (mineral gravel finish on upper side of the membrane) and sealing all overlaps of 100mm in length side and 150mm on width side of membrane by torching the same as per manufacture instruction and all as per specified particular specification all as specified and directed by Engineer in Charge.
Supply only Liquid water proofing compound (ISI Marked).
M&L for damp proof course in cement concrete 1:2:4,type B-0 40mm thick to horizontal or vertical surfaces including necessary formwork complete.
M&L preparation of new wood surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete.
M&L for Anti-termite treatment by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface. Note:- Area of the sub structure in contact with back fill shall be measured.
M&L for treating the top surface of filled earth at the rate of 5Ltrs of emulsion per square meter of surface.
M&L for treating the soil under plinth protection at the rate of 5Ltrs of emulsion per square meter of surface area.
M&L for treating the soil alongwith external perimeter of building at the rate of 2.25Ltrs of emulsion per meter of the perimeter wall.
Supply, Installation, Testing and Commissioning , natural oil cooled, dual shield, all copper winding and conductor, CRGO sheet core, three phase delta/star, 1:1 Isolation Transformer of capacity 10 KVA and input frequency 50 Hz +/- 3 Hz capable of handling input voltage variations 415 +/- 10% removing electrical noise, spikes effectively complete with overload & short circuit protection complete for its intended purpose all as specified and as directed.
M&L for earthing complete with copper earth plate electrode of size 60cmx60cm x 3.15 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including copper strip of 20 x 3 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete. Note: copper strip exceeding 7.5m long shall be measured & paid seperately.
S&F copper strip 20 x 3.15 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc all as directed by engineer-in-charge complete.
Supply & Fix in replacement,connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete for the cable size 16 Sqmm 4 core all as specified and as directed by the Engineer-in-Charge. Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule "A" .
Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in trenches, under road/ foot path and making good of size 20 mm bore complete all as specified and directed.
M&L For preparation of earth chamber made up of PCC 1:3:6 type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame and lead all as specified and as directed by Enger-in-charge.
M& L for preparation of the earth chamber lead with lifting handle madeup of chequred iron plate of thickness 5 mm supproted by 50x50x6mm equal angles on the top of earth chamber base including required PCC work all as specified and as directed by Enger-in-charge.
Supply & Fix in replacement of 100 Amps off-Load changover switch front operated including disconnection incoming & outgoing cables & fixing of new changover testing complete all as directed by EIC.
Supply & Fix in replacement,connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete for the cable size 25 Sqmm 3.5 core all as specified and as directed by the Engineer-in-Charge. Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule "A" .
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil soil complete all as specified and directed by Engineer-in-Charge.
S & F of tubes light grade of 50 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts complete all as specified and directed by EIC.
S&F MCB TPN 63 Amps suitable for 415 volt isolator as incoming complete all as specified and as directed.
S&F MCB SPN 40 Amps suitable for 215 volt isolator as outgoing complete all as specified and as directed.
S&F MCB SP 40 Amps suitable for 215 volt isolator as outgoing complete all as specified and as directed.
S&F 9 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative other side balancing white lamination, fixed with screws to timber frame work including necessary teak wood beading.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L in repairs for 20mm thick granite, z black (table rubbed and polished) for platforms, wall lining (veneering to wall), cills and in similar items, including rounding of exposed both edges, laid over 20mm thick bedding / rendering in cement mortar (1:4) and pointing with white cement(1:2) using marble dust with admixutre of pigment to match with shade of granite.
M&L for point wiring (concealed wiring) complete with FRLSH PVC insulated unsheathed 1100 volts grade, conforming to IS-694, 1.5 Sq mm (nominal area) multi stranded copper conductor cable drawn though in including non metallic medium grade rigid PVC conduit ISI marked, 19/20 mm dia including all accessories by chipping the existing wall for inserting the conduit on the surfaces of walls/floors/celling and making good the disturbed surfaces, and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for one light point/fan point/exhaust point controlled by one modular switch, one way complete all as specified and as directed by Engr-in-charge.
One light point controlled by one,one way switch single pole modular type
One Fan point controlled by one,one way switch single pole piano type
One 3 pin 5 Amp socket outlet on independent board .
One 3 pin 5 Amp socket outlet on same board .
All as per item No 120 above but wiring with 4 sqmm FRLS multistranded copper wire complete.
Supply and fix energy saving ceilling fan 1200mm sweep and connecting up including provision of cable from ceilling rose or connector to fan and all as directed by Engr-in-charge .Make : Usha or equivalent Bajaj/ Crompton Greaves/Havells.
S&F modular stepped type electronic fan Regulator 240 volts grade 120 watts 2 module heavy duty ISI marked.
Supply and fix modified celling fan huk Anchor fastner to be welded on iron supports for hanging 1200 mm 'sweep 'ceiling fan
M & L Modular switch 1 way 6A 1module.
S&F modular metal flush box 6 module
S&F modular white cover plate with frame of 6 module ISI marked Havells or equivalent make of Anchor/Polycab all as specified and directed.
Supply and fix in Replacement recessed mounting LED 2x2 luminaire with white acrylic flat light dissipater with LED light source of 36 Watt of size 2’x2’(Feet) square shape suitable for modular ceilingincluding cutting the existing false ceiling and fixing complete all as specified and as directed by Eng In Charge. Make : Havells or equlvalent in Bajaj/ Philips/CG/Orient/Polycab.
Mepani Construction Company
AARTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .