| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49 A GALLI NO 09 KAILASHPURI PALAM COLONY NEW DELHI 110045 | NEW DELHI | NEW DELHI | DELHI | 110045 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹8.6 L+₹26,720 (3.20%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NO,SLOW PROGRESS,SHOW CAUSE NOTICE ISSUED BY HQ CE DELHI ZONE LETTER NO 80000/WLR/B-50L/894/E8 DATED 29.12.2020 |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
25 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
MANNING AND OPERATION OF ELECTRIC SUPPLY INSTALLATION AT RTS DEPOT HEMPUR UNDER GEEAST BAREILLY
2020_MES_403448_3
C8883/E8
Open Tender
Miscellaneous Services
Item Rate
334 days
HEMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹26,000
Yes
10 Mar 2021
10 Feb 2021
27 Feb 2021
10 Feb 2021
25 Feb 2021
13 Feb 2021
10 Feb 2021 - 12 Feb 2021
60 days
Amount
Providing services for manning, operation and maintenance of 11 KV MRS (Main Receiving Station) comprising of HT control relay panel 11 KV HT RMU panel alongwith 400 KVA Transformer - 01 No , Servo Voltage Stabilizer 400 KVA - 01 No, APFC panel - 01 Nos and ACB Panel- 01 No, LT Panel - 02 Nos, 125 KVA DG Set - 01 No, Bus bar system GOD & DO system 2 and 4 pole structure, Submersible Pump with motor capacity 15 HP - 01 No and Over Head Tank capacity 25000 Gal - 02 Nos and all supply sluice valve, attend/fixing the complaint of burnt out over head line of HT/LT fuse, all cables & joints alongwith all connected accesories including entering and maintenance of external fittings of main incoming & outgoing feeder voltage, ampere, power factor details etc.. UPPCL breakdown, load shedding /shutdown, MES breakdown/shutdown in register /documents, lodging electric complaints on phone and cleaning of installation in all respect including operation of street lights at RTS & Depot, Hempur area and operation of pump house as per given timings complete by employing one skilled electrician per shift (08.00 hrs) in 03 shifts a day including sunday & holiday complete all as specified and directed
Providing services for attending daily electric complaints of external & internal as directed by concerned JE, attending external complaints, detecting fault in HT/LT overhead line /underground cables in electric distribution system including street lights under AOR of RTS & Depot, Hempur & attending daily internal complaints assigned by JE , detection of short circuit, fixing of fittings etc one skilled electrician per shift (08.00 hrs) in 02 shifts a day including sunday/Holiday (Time decided by Engr-in-Charge), complete all as specified and directed by Engr in Charge. Note :- (i) Mate Electrician (Helper) to be detailed from department side. (ii) All the spares require replacement during attending the complaint of external and internal electric fittings will issued by deptt as user requirement on daily basis .
NOTE FOR ITEM NO 1&2 ABOVE: (i) The MRS shall be operate in three shifts of 0800 hrs duration each shift on all days for 11 months & that will be maintained for the entire contract period except where if any altration is required to meet functional requirement for any installation during contract period. The shift duty staff is fully responsible for daily operations as per user requirements or as directed by Engr in charge. In case of any brake down of supply the same should be communicated to Duty electrician and consult with UPPCL Sub stn for restore the supply and inform to JE/Engr in charge. (ii) The contractor should procure the tools what ever is required as per requirement for smooth operation and repairs for Electrician. The tools includes Electricians Cutting pliers, Nose pliers, line tester, Screw drivers, Adjustable spanners, ring spanners and HT/LT ladder etc. including insulation tap, HT tape, jumper, fuse wire, lugs, indication lamp for HT/LT over head line and to be kept with substation(iii) The contractor should procure all the safety equipments what ever is required for smooth operation and maintanance works for operator. The equipments includes Electricians Hand gloveses, Safety belts, Helmets,ear pads, Earth discharge rods, etc. and to be kept with sub station (iv) The contractor should kept all the measuring instruments what ever is required for testing and maintenance works for electrician. The equipments includes test lamps, Tong tester, Multi meter, Earth testers, LT/HT Meggers,temp gauges/thermometers etc. and to be kept with Sub station(v) Diesel required for running the DG sets shall be issued by Deptt,.as free for filling through retail issue voucher, The consumables like electrolites/distilled water, petrollium jelly, grease etc also including minor repairs to DG Sets deemed to be incuded in the quated rate. (vi)All Tenderer are advised that read SchA notes and Specification of tender before quoting the rate.
D K THUKRAL AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .