Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.8 L+₹1.9 L (6.00%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹33.0 L+₹2.1 L (6.67%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹33.8 L+₹2.9 L (9.42%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BHUJ
CWE AF BHUJ KHAVADA ROAD 370001
MAINTENANCE TO CENTRAL AIR CONDITIONIG PLANTS AT AF STATION BHUJ
2023_MES_606154_2
84215/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF BHUJ
₹60,000
Yes
22 Sept 2023
8 Aug 2023
8 Sept 2023
9 Aug 2023
6 Sept 2023
23 Aug 2023
9 Aug 2023 - 23 Aug 2023
Amount
M & L for Preventive maintenance of LT panel of any size including tightening the connections of cable from MCCB / Contactor / switches, replacing all lug with new of any size aluminium / copper, replacing the complete internal wiring, copper cable by 16 Sqmm single core FRLS multistranded connection between MCCBs and connector , contactors , replacing connector of size 40 Amps to 100 Ams, TPN set by new connectors complete all as specified and directed. Note: Material such as 16 Sqmm copper wire, connector, contactor, MCB, MCCBs, Starters, phase preventer will be measured and paid saperately.
S & F in repair thermal overload relay (Auto / manual reset) for power contactor type NO/ NC having variable relay range from upto 25 Amps 3 Phase, 415 Volt all as per existing installed on site and as specified and directed by Engineer-in-charge. Note : Make shall be proivded as per existing make and as approved by GE
S & F in repair MCCBs 415 Volts, 4 Pole Fixed type 100 Amps with Braking capacity 25 KA all as specified and directed by Engineer-in-charge.
S & F in repair MCCBs 415 Volts, 4 Pole Fixed type to 125 Amps with Braking capacity 25 KA all as specified and directed by Engineer-in-charge.
S & F in repair MCCBs 415 Volts, 4 Pole Fixed type 160 Amps with Braking capacity 25 KA all as specified and directed by Engineer-in-charge.
S & F in repair MCCBs 415 Volts, 4 Pole Fixed type 250 Amps with Braking capacity 35 KA all as specified and directed by Engineer-in-charge.
S & F in repair MCB 415 Volts, 4 Pole Fixed type 40 Amps with Braking capacity 10 KA all as specified and directed by Engineer-in-charge.
S & F in repair MCB 415 Volts, 4 Pole Fixed type 63 Amps with Braking capacity 10 KA all as specified and directed by Engineer-in-charge.
S & F in repair Single phase preventer relay with adustable time on delay 6/7 wire , 415 V SPPR type SDz5 all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V ,9 Amps type NO/NC built in surge, along with auxiliary contactor as per installed / existing all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 12 Amps type NO/NC built in surge, along with auxiliary contactor as per installed / existing all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 18 Amps type NO/NC built in surge along with auxiliary contactor as per installed / existing all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 25 Amps type NO/NC built in surge along with auxiliary contactor installed / existing all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 32 to 40 Amps type NO/NC built in surge along with auxiliary contactor installed / existing all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 65 Amps type NO/NC built in surge along with auxiliary contactor installed / existing / Add on block (mino contactor) all as specified and directed by Engineer-in-charge.
S & F in repair 3 pole power contactor AC, 415 V, 100 Amps type NO/NC built in surge along with auxiliary contactor installed / existing / Add on block (mino contactor) all as specified and directed by Engineer-in-charge. Note for items No 3 to 16: Make shall be proivded as per existing make and as approved by GE
S & F in repair three phase cable connector with base strip 415 volts, TPN set 63 Amps all as specified and directed by Engineer-in-charge.
S & F in repair three phase cable connector with base strip 415 volts, TPN 100 Amps as specified and directed by Engineer-in-charge.
S & F in repair fan belts V shape of size B-79 having nylone thread reinforced and skid tigh tensile strength, notchs for proper griping on pully or wheel all as directed by Engineer in charge. Note: Make shall be fenner / Dunlop / Emcon or as approved by GE from make list of Appendix 'B'.
All as per item No.19 above but of size B-70
All as per item No.19 above but of size B-76
All as per item No.19 above but of size B-57
All as per item No.19 above but of size B-54
All as per item No.19 above but of size A-31
All as per item No.19 above but of size A-28
M & L for opening outdoor unit at site taking out unservisible condenser motor, S & F in repair burnt out unservisible condenser motor 0.37 Kw (0.5 HP), 230 V 50 HZ, 900 - 1000 rpm single phase from outdoor unit of package type AC plant complete all as specified and directed. Note: Make shall be proivded as per existing make and as approved by GE
M & L for opening outdoor unit at site taking out broken / defective condenser motor fan blade size 450 mm sweep , S & F in repair, testing condenser motor fan blade size 450 mm ( 3/ 4 blade ) suitable for 0.37 Kw (0.45 HP), 230 V 50 HZ, IP 55 single phase condenser motor sweep package type AC plant all as specified and directed by engineer - in charge.
Suply and fix in repair Dry all liquid line filter drier , working temperature range -400C to 800C, for respective capacity 5.5 TR to 12 TR AC plants with both end leak proof connection to liquid line all as per Engineer-in-charge. Note: Make shall be proivded as per existing make and as approved by GE
S & F in repairs expansion valve of capacity 5.5 TR / 6 TR all as per Engineer-in-charge.
S & F in repairs expansion valve of capacity 8.5 TR / 9 TR complete all as specified and directed.
S & F in repairs expansion valve of capacity 11 TR /12 TRcomplete all as specified and directed. Note for items No 29 to 31: Make shall be proivded as per existing make and as approved by GE
S & F in repair remote control set with remot circuit panel and suitable cord for Tower / wall mounted room air conditioner 4TR capacity all as specified and directed by Engineer-in-charge. Note: Make shall be proivded as per existing make and as approved by GE
S & F in repair remote control circuit set, electric panel and suitable cord including sensors , controller for package type AC plant 8.75 TR to 12 TR for controling temperature, cutoff compressor, on / off mode, fan swing with digital indicator / display by sensing all paremeters all as specified and directed by engineer in charge. Note: Make shall be proivded as per existing make and as approved by GE
M & L for opening air handling unit in AHU room , taking out air blower cuppled with 3HP to 10 HP electric motor, S & F in repair new central rotating shaft along with new pedestal block with bearing for bolwer shaft, on both side size inner dia 25 /65 mm, greasing, , testing and refixing same blower in air handling unit, closing air handling unit same as original all as specified and directed by Engineer-in-charge.
M & L for tracing out leakage location in AC plant refrigerant circuit ( suction /delivery line condenser line, valves, connection location) arresting the leakage location by brazing / soldering and Supply and filling refrigerant gas R-22 lossed in leakage / repair/ maint work including testing of pressure level, leakage.
M & L for tracing out leakage location in AC plant refrigerant circuit( suction /delivery line condenser line, valves, connection location) arresting the leakage location by brazing / soldering and Supply and filling refrigrant gas R-410A lossed in leakage / repair/ maint work including testing of pressure level, leakage.
M & L for tracing out leakage location in AC plant refrigerant circuit( suction /delivery line condenser line, valves, connection location) arresting the leakage location by brazing / soldering and Supply and filling refrigerant gas R-407 lossed in leakage / repair/ maint work including testing of pressure level, leakage.
M & L for disconnecting old unservisible compressor including electrical wire connection , suction and delivery line from installed location, fix in repair of scroll compressor capacity 4.0/4.5/5.0 TR for Gas R-22/ R407C/R410 for split type tower / casset AC / package type AC including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately. Note: Make shall be proivded as per existing make and as approved by GE
M & L for disconnecting old unservisible compressor including electrical wire connection , suction and delivery line from installed location, fix in repair of scroll compressor of 8.75 TR capacity model no CSC673___ /CSC753 in air/water cooled chilled based split type AC plant/ package type AC including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately.
M & L for disconnecting old unservisible compressor including electrical wire connection , suction and delivery line from installed location, fix in repair of scroll compressor of 8.75 TR capacity model no SM120___ in air/water cooled chilled based split type AC plant/ package type AC including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately.
M & L for disconnecting old unservisible compressor including electrical wire connection , suction and delivery line from installed location, fix in repair of scroll compressor having thread end (flare end) for suction and delivery of 12 TR capacity model no SM185____ in air/water cooled chilled based split type AC plant/ package type AC including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately.
M & L for disconnecting old unservisible compressor including electrical wire connection , suction and delivery line from installed location, fix in repair of scroll compressor having thread end (flare end) for suction and delivery of 12 TR capacity model no SZ185__ in air/water cooled chilled based split type AC plant/ package type AC including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately.
M & L for disconnecting old unservisible evaporator coil(Chiller) including piping connection , suction and delivery gas line from installed location, fix in repair of new evaporator coil (Chiller) suitable for 22 TR/24 TR air cooled Air conditioning unit including fixing , connection & out going pipe, pressure testing, welding, brazing connection basing etc all as originally fixed, specified and directed by Engineer-in -charge. Note: Refrigerant gas will be measured and paid saperately. Make : As per existing make and as approved by GE.
Disconnecting the electric connection of the defective motor of any make from panel board , dismentling from centrifugal pumping set/ bolwer / colling tower, transporting to workshop and dismentling motor , taking out burnt copper winding of motor, cleaning the casing, pump with wire brush, rewinding the motor using synthetic enamelled copper wire of existing gauge, re-assembling the motor to its original form, after repair of defective parts as its original parts , bringing back to site of work, reconnecting electrical connection , recoupling with centrifugal pump set for satisfaction running to the satisfactory of Engineer-in-charge for the capacities 7.5 HP to 10 HP of motors.
All as per item no 50 but of capacity 5 HP
All as per item no 50 but of capaci 2 HP to 3 HP
M & L for descaling of condenser shell and tube using sulphamic acid and feeding in a cyclic way by high pressure pump for 30 min cycles till the PH valve of fresh water inserted & collected is 7.0 and cleaning outer part with brush and rod by suitable method including S & Fing rubber gasket all as directed by engineer in charge.
S & F in repair PVC fills as per existing at site to its original quantity and position of cooling tower modular construction FRP type of capacity 30TR-50TR all as directed by engineer in charge.
S & F in repair of Copper condenser with copper fins installed in outdoor of 8.75TR (50 X 36 X 2 mm) Package/Central type AC plant including connection of suction and delivery line, pressure testing all as directed by engineer in charge.
S & F in repair of Copper condenser installed in outdoor of 5.5TR (50 X 28 X 2 mm) Package/Central type AC plant including connection of suction and delivery line, pressure testing all as directed by engineer in charge.
S & F in repair of Copper condenser installed in outdoor of 11TR / 12TR (77 X 45 X 2 mm) Package/Central type AC plant including connection of suction and delivery line, pressure testing all as directed by engineer in charge.
M & L for cleaning and removal of the dust from Outdoor unit/Air handling unit/ Cooling coil of central/Package Type AC plant of 5.0 to 50.0 TR by washing with water or by suitable method including cleaning of air filter, supply and replacement of damaged wires with copper wire PVC insulated of existing size, tightening of loose wire, nuts, bolts, servicing of condenser motor by oiling, greasing, setting of grills alignment complete including refixing in original position including provision of thermocol for air tightness, testing and commissioning to the entire satisfaction complete all as specified and directed by Engr-In-Charge.
S &F three way motorized valve suitable for chilled water pipe line 65mm to 100mm dia of 44.0 TR Air conditioning plant complete all as specified and directed by Engineer -in-Charge. Note : Make shall be provided as per existing make and as approved by GE.
S & F in repair thermister temperature sensor suitable for 22.0 TR/24.0 TR aircooled chiller. Note : Make shall be provided as per existing make and as approved by GE.
1R K Traders
M/s Bombay Novelty Stores
shivrefrigeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .