| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.0 L+₹2.2 L (24.6%)Rejected-Finance SHOP NO 02 DADA COMPLEX NEAR DENA BANK NALIYA TAL ABDASA KUTCH GUJRAT 370 655 | KACHCHH | GUJARAT | 370655 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
26 May 2020, 6:00 pmClosed
AGE I CG JAKHAU
AGE I CG JAKHAU ABDASA KUTCHH 370655
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION, CELING FAN, WITH MISC ALLIED WORKS AT ICGS JAKHAU AND CGRA NALIYA UNDER AGE I CG JAKHAU
2020_MES_341247_1
8033
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CG NALIYA AND JAKHAU
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
AGE I CG JAKHAU
₹19,800
Yes
2 Jun 2020
27 Apr 2020
28 May 2020
27 Apr 2020
26 May 2020
12 May 2020
Amount
Taking down carefully copper point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.
M & L for concealed existing conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor controlled by one switch including continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable connected to common earth dolly with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour complete all as specified and directed by the Engineer in charge.
All as per Srl item no -2 here in before but for one socket 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 2 here in before but for one socket 3 pin 15 Amps on independent board with 2.5 Sqmm copper cable complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No -2 here in before but for one three pin socket 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
M & L for point wiring complete with 1.5 Sqmm PVC insulated and unsheathed FRLS cable single core multi stranded copper conductor, 1100 volts grade drawn through and including PVC casing / capping including copper earth continuity wire of PVC insulated of size 1.50 Sqmm and connected to common earth dolly with all accessories complete as specified for : -
All as above item no- 6 but One light point controlled by one switch
All as above item no- 6 but One fan point controlled by one switch through regulator
All as above item no- 6 but One Exhaust fan point controlled by one switch .
All as above item no- 6 but One 3 pin socket out let 5 Amp on independent board
All as above item no- 6 but One 3 pin socket out let 5 Amp on same board
All as above item no- 6 but One bell/buzzer point controlled by one push button
All as per item No.6 above but with 2.5 sqmm single core cable for one 3 pin socket outlet 15 Amps on independent switch board indluding 1.50 Sqmm as earth continuity conductor and connected to common earth dolly.
S & F in replacement flush type switch socket outlet combination 2 in 1 ,multipurpose 3 pin, 5/15 Amps and 3 pin 5 Amps.
S&F in replacement switch piano flush button SP one way 5 Amp
S&F in replacement socket piano flush type 5 Amp
S&F in replacement switch socket combination 5 pin 5 Amp ,flush type, multipurpose all as specfied and directed
S&F in replacement bell Ding Dong, AC, 230 volts, single pole controlled by one bell push all as specified
S&F in replacement bell push, AC, 230 volts, single pole all as specified
S&F in replacement electronic step speed regulator, suitable for 1200 mm sweep ceiling fan up to 300 watt all as specified.
S&F in replacement lamp holder PVC/ Polycarbonate type with cord grip cap, insulated body, threaded dome pattern, suitable for pendant fittings.
S&F in replacement Modular switch 1M 6 Amps
S&F in replacement Modular switch 1M 15 Amps
S&F in replacement Modular Socket 2M 6 Amps
S&F in replacement Modular Socket 2M 15 Amps
S&F in replacement Modular Fan Regulator 2M
S&F In replacement Modular cover plate 3M
S&F In replacement Modular cover plate 6M
S & F in replacement LED batten integrated channel 18 watt having input voltage AC90-300V, 50 Hz , 6500K ,extruded aluminum body with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector and making good of existing wall surface complete all as specified and directed by Engineer - in - Charge. (Make: SYSKA LED Cat No SSK-SQ1801) and equivalent of Wipro/philips.
S & F in replacement compact & decorative energy efficient self ballasted LED batten , aluminium extruded body with PC diffuser LED tube light fitting and decorative end caps suitable for 1X10/12 watt fitting 2 ft version including LED lamp 10 watt and making good of existing wall surface complete all as specified.Make:-C&S Cat part No.LTTB2F10WLED/Wand equivalent of Bajaj/philips.
S & F in replacement LED 5watt integrated batten , energy efficient self ballasted , aluminium extruded body with PC diffuser LED tube light fitting and decorative end caps 1 ft white version including LED lamp 5 watt and making good of existing wall surface complete all as specified.Make:-C&S Cat part No.LTTB1F5WLED/W equivalent of Bajaj/philips.
Supply and fix in replacement Recess mounting LED 18/16 watt luminaire White powder coated CRCA housing with LEDs. Seamless front frame with flat white high transmission acrylic cover and fixed electronic driver (surge protecter) complete cat No LTCRSLM16HPLEDSQ/W MAKE C&S or Philips/havells
S&F in replacement of building security light fitting with LED TYPE 25 watt optic lenses with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge or Bajaj cat part No.BCLST 25 LED/SYSKA Cart part No.SSK-ST-25W/C&S Cat Part No.LTESSE25WLED/poly cab cat part No. PCGLS 25 L
M&L for Sub main wiring with two run of 4sqmm single core, PVC insulated but unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through in PVC casing caping/ Surface Rigid PVC Conduit with all accessories and 4 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire by including taking down old wiring complete all as specified and directed.Note: Two run of PVC cable with one run of PVC earth wire and one run of casing caping shall be measured and paid as one length only.
All as per Item No.34 above but with 2 runs of 6 sqmm and 1run of 6 sqmm
All as per Item No.34 above but with 2 runs of 2.5 sqmm and 1run of 2.5 sqmm
All as per Item No.34 above but with 2 runs of 1.5 sqmm and 1run of 1.5 sqmm
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / L&T)
S & F in replacement sheet metal enclosure for double door BD made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / L&T)
S & F in replacement sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 4 ways, 440 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCCB and isolators etc including fixing in Wall with Cement mortar complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Standard / Indo Asian Cat part No.811888)
S&F in replacement MCCB TPN 63 Amps with breaking capcity 25kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. (Make - Havells / Legrand / Indo Asian)
Supply and Fix in replacement the following MCBs of approved make, 'C' curve type & 10 KA breaking capacity, at locations as directed
Four pole 63 Amps
Two Pole 32 Amps
SP 6-32 Amps
S & F in replacement industrial plug socket with 20 Amp MCB with sheet metal enclosure and plug top and conduit box and all fixing arrangement on wall.
S&F in replacement Fluorescent tube light fitting flamproof type FLP-WP of T5 1X28 W including integral reflector made of alumnium alloy LM6, With electrnoic ballast bipin holders connector block etc and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size all as specified and directed
M & L in replacement for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 1991and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.
Outsourcing of servicing for daily complaint cell and attending daily routine electrical complaints of buildings and installations/street light/security light/finding fault in cables within specified time located in CGRA,naliya station and ICGS Jakhau station by providing 01 (one) Electrician Semi-skilled+01(one) Helper unskilled in Morning shift of 8 hours from 9:00 to 17:00 Hrs per day Note:- (i) T&P items,insulation tape,complaint slip and complaint register as per prescribed format will be provided by contractor. (ii) Electrician on complaint duty shall take complaints and he should be responsible to render feedback. (iii) Veh for attending E/M complaints and shifting of Sch 'B' store shall be on contractor's arrangment (iv) Store required for complaints will be issued under Sch 'B' of elect supply store. (v) Employ Electrician ITI Certificate holder from Government/Government recognised Institute having minimum 02 years of working experience in the trade only (vi) Electrician & helper shall paid their wages/ salary through bank account only and the proof there of shall be produced Striclty by the contractor while claming the Payment and their wages shall not be less than minimum wages fixed by labour commissioner. (vii) If the Electrician & helper is found Absent from duty a recovery of Rs 500/- per person shall be effected from contractor's RAR or Final Bill in addition to non payment of manning and and operation charges as per CA
Dismantling of complete Ceiling fan 1200/1400 mm sweep (i.e.,) down rod with its Canopies, Shackle, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding of starter with suitable size of Copper enamelled wire, varnishing heating as per manufactures design and directed. (b) Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.,) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
All as per Item No.50 above but exhaust fan of size up to 300 mm sweep.
All as per Item No.50 above but wall mounted fan of size 450 mm sweep. Note: for Item No. 50 to 52: (a) Supply only spare parts found unserviceable/defective will be measured and paid separately under relevant item of Sch 'A'. (b) The rate for refixing/ replacing unserviceable items are deemed to be included in unit rate of above item. (c) The Contractor has to quote credit for all retrived unserviceable item obtained from dismantling separately under relevant item of 'Schedule of Credit'.
Supply only the following spare parts of Ceiling fan of different makes 1200mm /1400mm sweep of different make.
Condenser for ceiling fan 2.5 mfd capacity make:- havells/usha/anchor
Ball bearing for ceiling fan as per existing size.
S& F in Replacement of PVC exhaust fan motor size 250 mm as per exiting size/make
S & F in Replacement foam net nozzle made up of gun metal chromium plated complete all as specified and as directed. Make: Creative or from Nova / Uxcell / Fontana as approved by AGE
S & F in Replacement 25mm bore Gun metal Angular valve with chromium plated complete all as specified and as directed.Make: Creative or Hindware / Jindal / Fontana as approved by AGE
S & F in Replacement LED based colour changing light from Red, Green, Blue, water tight with operating voltage of 18 Volts, DC, mounted near nozzel of fountain and connected from controller to lights with necessary tin/silver plated copper cabling complete all as sepcified and as directed.Make: Creative, Model 96 R or its equivalent from Fontana / ACME lighting / Techshop as approved by AGE
S & F in Replacement pop-up sprinkler made up of PVC of rating Cap 0.25 LPS and size 15 mm dia for sprinking area of 10m dia with necessary fixing accessories complete all as specified and as directed.Make: Hunter, Jain Irrigation, Rain bird
M&L for applying two coats of synthetic enamel black paint on garden lights height upto 1.0 mtr from GL including preparation of surfaces complete as per site direction complete all as specified and as directed.
M&L for painting of GI pipe bracket and clamp any size on bldg security lights applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete as per site direction complete all as specified and as directed.
Taking down the following existing worn out spares of Split type Air conditioners 1.5 Ton / 2.0 Ton capacity; supply and fix in repair new spares of make and model all as specified and as directed:-
Blower Motor Indoor Type (Make : GE/ LG/ BlueStar)
Fan Motor Out door Type without blades (Make : GE/ LG/ BlueStar)
Fan Blade for outdoor unit
Starting Capacitor 35 to 45 MFD (Tibcon/ Baba/ Tipcon)
Running Capacitor 50 to 60 MFD (Tibcon/ Baba/ Tipcon)
Air filter for Indoor Unit
Display for Indoor unit of existing Make: LG/ Voltas/ Videocon
Remote control (Hand set only) with Battery of existing Make: LG/ Voltas/ Videocon
LDPE drain water pipe 15 mm bore
M&L for replacement Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit all as directed. Make: Baba/ Wavess or its equivalent as approved by GE
M&L for replacement ,Opening the indoor unit front panel of wall mounted split type 1.5/ 2 Ton AC for cleaning the existing LDPE pipe for any block by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water complete all as specified and as directed.
M&L for replacement ,Taking out unserviceable Rotary type compressor of Split type AC 1.5 ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and as directed. Make: Copeland/ Tecumseh/ Highly
All as per item No 75 above but for Split Type AC 2 Ton capacity, Make: Copeland/ Tecumseh/ Highly
M&L for Top up / Gas charging with refrigerant gas (R-22) for Air conditioner window type / split type of capacity 1.5 / 2 / 11 Ton after vacuuming & leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
Supply & fix in replacement copper tubing suction and liquid line from Indoor to out door unit suitable for Split A/C 1.5 TR / 2 TR including insulation on copper tubing complete all as specified and as directed.
Supply and fix in replacement condenser coil made up of copper for split AC 1.5 TR/2.0 TR complete all as specified and as directed.
Taking down existing split type AC from one location and re-fixing the same in another location as directed, including replacement of copper wire require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU for smooth functioning, complete all as specified & directed.
M&L for servicing of Split AC 1.5 TR / 2.0 TR complete indoor/outdoor type units means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chillier units is done with use of nylon brushers till the scaling is removed including replacment insulation of exiting copper tubing inlet-outlet complete all as specified and as directed.
Taking down electric water heaters (geysers) of capacity 25 Litres storage type, disconnecting of electric and water connections, taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly, cleaning the inner shell (copper) with Mack solution including thermostat, geyser assembly and heating element, testing the inner tank for any leakage and rectification by soldering / brazing. Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete all as specified and directed by Engineer-in-Charge. (Note : Inner Shell, outer Cover, thermostat switch, geyser element and geyser assembly, bottom covers shall be measured and paid as supply only separately , if replaced as required).
Supply only inner ss shell for storage type water heater 25 Litres capacity to match the existing model of geysers complete all as specified and directed by Engineer-in-Charge. (Make : As per sample and as approved by Garrison Engineer)
Supply only, heating plate assembly apparatus plate with PVC rubber ring suitable for 25 litres capacity complete all as specified and directed by Engineer-in-Charge. (Make : As per model of Geyser.)
Supply only, heating element push type, 1500 watt of suitable shape and size, conforming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge. (Make : Daspass / Micron / other ISI make as approved by Garrison Engineer).
Supply only, thermostat switch suitable for storage type geysers complete all as specified and directed by Engineer-in-Charge. (Make : Bajaj, Spherehot, Racold / other ISI make as approved by Garrison Engineer)
S & F in replacement, PVC connection wire woven 15mm size with nickel plated brass adapter, both sides threaded, in standard length of 30cm to suit the size of geysers complete all as specified and directed by Engineer-in-Charge.
M & L Spray painting to geysers of 25 litres capacity with one coat of synthetic enamel white paint externally after preparation of surfaces including writing MES numbers with black paint in 25mm size letters, complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, solar plate made out of toughened glass of size 200cm x 103cm, thickness 6mm as per existing model complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, solar heating element with inbuilt thermostat of 2000 Watt as per existing model complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening up the defective Voltage Stabilizers of capacity 4.0 /5.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enameled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling all as specified and directed by Engineer – in - Charge. Make of winding wire : HTP, Atlas, Chetak, Devidayal
Deduct credit for dismantled materials as per schedule of credit Rs 32,485/-
NEELKANTHA ASSOCIATE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .