Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L1 | Accepted-AOC L1 BID. | |
| 2 | L2₹26.4 L+₹3.0 L (12.8%)Rejected-Finance 4 E K N BANERJEE ROAD KOLKATA 700 057 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹28.6 L+₹5.2 L (22.1%)Rejected-Finance | L3 | Rejected-Finance NOT L1 BIDDER | |
| 4 | L4₹29.3 L+₹5.9 L (25.1%)Rejected-Finance M C DEPT SANTALDIH THERMAL POWER STATION SANTALDIH DIST PURULIA WEST BENGAL PIN 723146 | PURULIA | WEST BENGAL | 723146 | L4 | Rejected-Finance NOT L1 BIDDER | |
| 5 | L5₹38.2 L+₹14.8 L (63.2%)Rejected-Finance | L5 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹35.7 L
EMD Value
₹71,424
Closing Date
8 Feb 2020, 5:00 pmClosed
GM/STPS
1st floor,Admin. Building,Santaldih Thermal Power Station, Santaldih,Purulia
Repairing, maintenance and painting of steel structure of TP/32, TP/36, TP/39 and TP/40 at CHP of STPS.
2020_WBPDC_263814_1
WBPDCL/STPS/NIT/E1950/19-20
Open Tender
Support/Maintenance Service
Item Rate
120 days
Santaldih Thermal Power Station
AS PER TQR OF NIT.
3 documents required · 3 mandatory
₹1,180
The West Bengal Power Development Corporation Ltd.
₹71,424
1st floor,Admin. Building,STPS
1 Jul 2020
4 Jan 2020
11 Feb 2020
4 Jan 2020
8 Feb 2020
16 Jan 2020
14 Jan 2020
Amount
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
Brick work with Fly Ash Bricks set in cement sand mortar (1:6) including raking out joints, curing, scaffolding etc. complete in all respect. a) In ground floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). 15 mm thick plaster (with 1:6 cement mortar)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). 10 mm thick plaster (with 1:4 cement mortar)
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface.
Painting with ready mixed red lead paint of approved make and brand :One coat
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (Including scaffolding up to any height) (a) On steel or other metal surface : With super gloss (hi-gloss) - (i) Two coats (with any shade except white with first coat with light shade & second coat with deep shade as per instruction of E.I.C)
Scraping of moss, blisters etc.thoroughly from surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: a) One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction For works in foundation and upto roof of ground floor/upto 4 m Tor steel/Mild Steel (SAIL/ TATA/RINL(Supplied by the agency)
Supply of UPVC pipes (B Type) & along with all necessary fittings conforming to IS-13592-1992 along with all necessary arangement including labour in all respect to divert the existing rain water pipe at the site of work as per direction of E.I.C.
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For structural members of specified sections weighing less than 22.5 Kg./m
Supplying, fitting & fixing with all necessary materials such as bend/socket/clamp etc in all respect in proper position of UPVC pipes (B Type) conforming to IS-13592-1992 as a rain water pipe of 160 mm dia including replacement of any damaged portion of pipe or bend or any fittings if as per direction of E.I.C.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall). 3 mm thick (weighing 7.4 kg/Sq.m)
Renewing worn out putty of glass panes at any hight.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
RUDRA ENTERPRISE
M/S PANCON
CIVIL CONSTRUCTION & MAINTENANCE CONTRACTOR
M/s. SARKAR AND SARKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .