Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.6 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹13.8 L+₹3.8 L (38.4%)Rejected-AOC HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | - | Rejected-Technical Not enlisted in eligible Cat and past experience doc not uploaded | |
| 4 | Rejected-Technical SHOP NO 02 DADA COMPLEX NEAR DENA BANK NALIYA TAL ABDASA KUTCH GUJRAT 370 655 | KACHCHH | GUJARAT | 370655 | - | Rejected-Technical Not enlisted in eligible Cat and past experience doc not uploaded | |
| 5 | Rejected-Technical 0 NEAR SATYANARAYAN SOCIETY GAYATRI MANDIR ROAD 0 BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | - | Rejected-Technical Not enlisted in eligible Cat and past experience doc not uploaded |
Tender Value
₹9.9 L
EMD Value
₹19,900
Closing Date
3 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NALIYA No 01
GE Air Force Station Naliya No 01
COMPREHENSIVE MAINTENANCE AND REPAIRS TO COOLING AND PAKAGE TYPE AC AT AF STN MOTHALA
2021_MES_480119_1
8786/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF NALIYA No 01
As Per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF NALIYA No 01
₹19,900
Yes
21 Jan 2022
6 Oct 2021
5 Nov 2021
6 Oct 2021
3 Nov 2021
20 Oct 2021
6 Oct 2021 - 12 Oct 2021
60 days
Amount
Taking down the Split type Air conditioners 1.5 Ton / 2.0 Ton capacity to check and repair worn out spares of existing Blower Motor Indoor Type, Supply and fix new spares of make and model as existing as given below complete all as specified and as directed. Make : GE / LG / BlueStar
All as per item No. 1.00 above but Fan Motor Out door Type without blades
All as per item No. 01 above but Fan Blade for outdoor unit
All as per item No. 1.00 above but Starting Capacitor 35 to 45 MFD Make : Tibcon / Baba / Tipcon
All as per item No. 1.00 above but Running Capacitor 50 to 60 MFD Make : Tibcon/ Baba/ Tipcon
All as per item No. 1.00 above but Air filter for Indoor Unit
All as per item No. 1.00 above but Display for Indoor unit of existing Make: LG/ Voltas/ Videocon
S&F in repairs Remote control (Hand set only) with Battery complete all as specified and as directed. Make: LG/ Voltas/ Videocon
S&F in repairs LDPE drain water pipe 15 mm bore
S&F in repairs Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit complete all as speicified and as directed. Make: Baba / Wavess
Opening the indoor unit front panel of wall mounted split type 1.5 / 2 Ton AC for cleaning the existing LDPE pipe for any block by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water complete all as specified and as directed.
Taking out unserviceable Rotary type compressor of Split type AC 1.5 ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and as directed. Make: Copeland / Tecumseh / Highly
All as per item No. 12.00 above but for Split Type AC 2 Ton capacity, Make: Copeland / Tecumseh / Highly
M&L for Top up / Gas charging with refrigerant gas R-22 for Air conditioner window type / split type of capacity 1.5 / 2 / 5.5 / 11 Ton after vacuuming & leak testing including bracing suction / discharge line and testing complete all as specified and as directed.
Supply & fix in replacement copper tubing suction and liquid line from Indoor to out door unit suitable for Split A/C 1.5 TR / 2 TR including insulation on copper tubing complete all as specified and as directed.
Supply and fix in replacement condenser coil made up of copper for split AC 1.5 TR / 2.0 TR complete all as specified and as directed.
Taking down existing split type AC from one location and re-fixing the same in another location as directed, including replacement of copper wire require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU for smooth functioning, complete all as specified as directed.
M&L for cleaning of complete indoor / outdoor window type units of size 1.5 / 2.0 TR capacity split type air conditioner by means of adding, cleaning solution HCL or any suitable solution with water, cleaning of the condenser and chillier units is done with use of nylon brushers till the scaling is removed complete all as specified and as directed.
M&L for Top up / gas charging with refrigerant R134A of required quantity for water cooler / water dispencer / Refrigerator / Deep freezer of any make including leak testing, necessary brazing of suction and discharge line and testing complete all as specified and as directed.
M&L for cleaning of 40/80 Litres size and capacity of Water coolers / Refrigerators(upto 320 ltr) / Deep freezers(300 ltr) by including cleaning of water cooler tank with use of bleaching powder and cleaning of condenser coil of water cooler by means of adding cleaning solution HCL or any suitable solution with water cleaning of the condenser and chillar units is done with use of nylon brushers till the scaling is removed complete all as specified and as directed.
Dismantling and taking out Compressor hermatically sealed suitable for 40/80 litre capacity water cooler unserviceable compressors for replacement from the existing water cooler / refrigerator / Deep freezer after cutting carefully the suction and discharge line, refixing the new compressor including first filling of gas and serviceable accessories with brazing the suction and discharge line and leak testing complete all as specified and as directed. Makes :Copeland/ Tecumseh/ Highly/Godrej
All as per item No. 21.00 above but Compressor hermetically sealed suitable for Refrigerator of 165 to 310 ltr Capacity
All as per item No. 21.00 above Compressor but hermetically sealed suitable for any capacity deep freezer
S & F in repairs thermostatic switch in replacement for Water cooler 40/80 liter capacity or refrigerator 165 to 310 Ltr & Deep freezer existing appliances complete all as specified and as directed. Make : Danfoss / Indofoss / Whirlpool / Honeywell
S&F in repairs for pump suitable for desert cooler as existing make & model, ISI marked, including taking down/out unserviceable motor& pump all with wiring complete all as specified and as directed
S&F in repairs for fan motor & fan with blade suitable for desert cooler of any capacity/make complete all as specified and as directed. Make: AUE/GE motors
Carefully opening the AC units, taking down any parts / accessories such as compressor, blower motor etc for repairs after disconnecting electric connections and taking out the defective parts for repair/replacement and re-assembling the AC after repairs, re-fixing only serviceable accessories and re-fixing the ACs to its original position including electric connections and copper tubing and testing complete for 5.5 / (2 x 5.5) 11 Ton Capacity Package AC's complete all as specified. Note : The rate quoted under this item is deemed to include for each job consisting of labour only for replacement of compressor/blower motor etc. of each AC unit. Supply only of the compressor/blower motor shall be measured and paid separately.
Supply only new compressor sealed units sutiable for unit dismantled form item No.1, as per existing any make and model, including brazing / welding of suction and discharge line, Including first filling gas and leak testing complete 5.5 Ton Capacity suitable for 5.5/(5.5X2) 11 TR package AC complete all as specified and as directed Make : Tecumseh/ Danfos/ Blue star / Copeland
Supply only blower motor of outdoor unit of any make and model as existing in position for unit dismantled under item No.1 above including other connected accessories of 5.5 Ton / (5.5X2) Ton Capacity package AC Make : AUE/GE/Crompton Greaves/Marathon
All as per item No 29.00 here in before but blower motor of indoor unit suitable for 5.5 / (5.5X2) Ton Capacity package AC complete all as specified and as directed. Make : AUE/GE/Crompton Greaves/Marathon
S&F in repairs synthetic woven Air filter for indoor unit, make and model as per existing for 5.5 Ton/(5.5X2)11TR Capacity, of existing make complete all as specified and as directed
Supply and fixing in repairs remote sensing display unit with remote & cord as per existing make and model for 5.5 TR/(5.5X2)11TR Capacities Package ACs of Existing Make complete all as specified and as diected Make: Blue star
Supply and Fix in replacement 'V' belt of existing size suitable for in door unit of 5.5/(2x5.5) ton package type AC units complete all as specified and as directed.
Supply and fix in replacement contactor 3 Phase suitable for existing 5.5/(5.5X2)11 TR all as specified and need as per site complete all as specified and as directed. Make L&T/ Siemens / Minilec/Schneider
S&F in replacement single/three phasing preventer suitable for 5.5/(5.5X2) 11 TR AC units complete all as specified and as directed Make L&T/ Siemens / C&S / Minilec
S&F in repair LDPE drain water pipe line, 25mm bore, including fittings complete all as specified and as directed.
S&F in repair gas charging valve of suction or discharge line suitable for 5.5 Ton / 11 Ton capacity AC units as per existing make & model complete all as specified and as directed
S&F in repair expansion valve suitable for 5.5Ton / (5.5X2) 11 Ton capacity AC units as per existing make & model including cutting, brazing / welding, leak testing complete all as specified and as directed Make: Voltas/Bluestar/ Danfoss
S&F in repair Liquid line air dryer with 100% molecular sieves and max working pressure of 500 PSIG suitable for 5.5Ton / (5.5X2) 11 Ton capacity AC units as per existing make & model including cutting, brazing / welding, leak testing complete all as specified and as directed Make : Danfoss / Dwelfoss/ Bluestar/ Voltas
Carefully opening the AC units, taking down any parts / accessories (Bearing, Shaft along with blower motor etc) for repairs after disconnecting electric connections and taking out the defective parts for repair / replacement and re-assembling the A/C after repairs, re-fixing only serviceable accessories and re-fixing the ACs to its original position including shaft and bearings qty 02 nos and including labour charges and testing complete for 5.5 / (2 x 5.5) 11 Ton Capacity Package AC's.(Material and Labours) complete all as specified & directed.
S&F in replacement MCCB 4 pole 16 KA with Fixed type thermal and magnetic setting, of 125 Amps complete all as specified and as directed. Make (L&T/Havells/Indo Asian/Schneider)
All as per item No. 41.00 above but of 100 Amps
S&F in replacement MCB TPN 63 Amps, 10 KA, 'C' series complete all as specified and as directed. Make : L&T/Havells/ Schneider
Supply and fix in replacement industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and as directed.
Supply and fixing / drawing wiring for Circuit / Submain wiring with PVC casing caping of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures / fittings fixed on wall / ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 6.0 sqmm and 1 x 6.0 sqmm as earth wire Complete all as Specified & directed.
Supply and fix in replacement of indoor unit of 1.5 / 2.0 TR air conditioner complete including all connected items for indoor unit & removing old indoor unit and fixing of new unit with accesories complete all as per specified and as directed.
M&L for Top up / Gas charging with refrigerant gas (R-410) for Air conditioner window type / split type of capacity 1.5 / 2 Ton after vacuuming & leak testing including bracing suction / discharge line and testing complete all as specified and as directed.
S & F in replacement of PCB set (Indoor and outdoor) electronic switch suitable for 1.5 TR split AC Inverter Type complete fitting and testing all as directed by EIC. Make Carrier / Blue Star / LG
Supply only bearing set of two suitable for (5.5x2) 11TR packaged AC blower shaft complete all as specified & directed.
Supply only blower suitable for (5.5x2) 11 TR packaged type AC blower shaft complete all as specified & directed.
Supply only shaft suitable for (5.5x2) 11 TR packaged type AC blower shaft complete all as specified & directed.
M/s Gee Cee Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .