| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹52.3 L+₹2.8 L (5.62%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
26 Sept 2024, 6:00 pmClosed
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
SPECIAL REPAIR TO BLDG NO P-53A ALONGWITH PROVN OF APPROACH PATH, MESH COVERS AND FENCING FOR CERTAIN SWTs AT AF STN BHUJ
2024_MES_669026_1
8764/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹96,400
Yes
16 Dec 2024
31 Aug 2024
28 Sept 2024
31 Aug 2024
26 Sept 2024
13 Sept 2024
4 Sept 2024 - 7 Sept 2024
Amount
Demolition Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Material & labour for 25 mm PCC 1:3:6 type C-0 (using 12.5 mm graded stone aggregate) as in roof padding complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 10mm thick in CM 1:3 over RCC roof mixed with water proofing compound @ 3% by weight of cement finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for manually cleaning tha all surface removing of loose particles dust, cement etc prefebly cleaning by using mechanical equipment's like wire/Tar bruch, also use water pressure machine wash the terrace surface area open tiles joint area then use choksey SBR-800 & Cemnt to grout the open tile joints then use Epoxy tile grout to fill up this all tiles joint area complete all as specified and directed by Engineer-in-Charge.
Material & labour for clean the all surface and start the waterproofing chemicals application choksey colour membrane ezee as prime coat use 1 ltr chemical +1 Litre water then aplications of 45 GSM gio testiles clothswoth two coats of choksey colour membrane ezee complete all as specified and directed by Engineer-in-Charge.
Material & labour for application of interior & exterior walls cracks cut cracks with the help of grinder then use choksey paintex -4 CNS-50 & techseal RDL PU1 etc materials to fill up this cracks complete all as specified and directed by Engineer-in-Charge.
Removal of damaged concrete along with loose damaged and cracked concrete/cover concrete at ceiling up to beyond the corroded steel reinforcements to a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer,pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement and removal and disposal of debris within owners premises including all plant and machineries complete all as specified and directed by Engineer-in-Charge. . Note : Rates quoted for all items should include working upto 6m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tightfitting,dust-resistant goggles and mask during breaking and surface grinding works etc.
Material & labour for epoxy bond coat providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat nitobond EP- epoxy resin concrete bonding agent supplied in 1/2, 1 and 4 Litre packs, having specific gravity 1.15 to 1.2 gm/cc, compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, shear strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C, high bond strenght high bond strength : Bond strength is more than the tensile strength of good quality concrete, barrier coat : Acts as a ‘barrier coat’ to the migration of chloride ions from host concrete. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Typical application includes cleaning all loose dust, dirt, grease from host concrete surface by suitable means, mixing both components of bond coat by heavy duty slow speed mixer until a uniform consistency, apply unbroken coat of Nitobond EP with stiff brush covering complete area of patch repair before placing mortar or micro concrete. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 6 m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines :
Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Barrier creams provide additional skin protection. Do not smoke during use. Maintaine ample ventilation. If contact wiith the resin occurs, wash immediately with a strong detergent or a resin removing cream. Eye contamination must be immediatelywashed with plenty of water and medical treatment sought. complete all as specified and directed by Engineer-in-Charge.
Material & labour for polymer modified mortar-patch repair (Up to Grade M45) providing and laying Renderoc SP 40- shrinkage controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength(BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength(BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Typical application inclues mixing entire bag with clean water about 4.25L to 4.5 L, mixed in suitable container with heavy duty slow speed mixer machine to achieve uniform lump free mortar consistency, placing and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles and mask if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water remove dust, debries/ rubbish etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 15mm thick in cement Mortar 1:4 (external) on brick walls or on concrete surfaces in two coats, 1st coat of 10mm thick and 2nd coat of 5mm thick including mixing with WPC to 2nd coat as per manufacturer's instructions, plastered surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE : Integral water proofing compound shall be measured and paid separately as ‘supply only’ under relevant Items
Material & labour for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new plastered surfaces and applying two coats of distemper with acrylic washble distemper, white or tinted including one coat of wall care putty by finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of plastered or unplastered old decorated external surfaces of walls and applying two coats of exterior emulsion paint in camouflage pattern as approved by the GE complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment on wall surfaces and applying two coats of distemper with acrylic washble distemper, white or tinted including one coat of wall care putty by finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-Charge.
Material & labour for reparation of old painted sufaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint on steel and iron surfaces on roof coverings in camouflage pattern (as approved by GE) complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old painted sufaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint on wooden surfaces on roof coverings in camouflage pattern (as approved by GE) complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material & labour for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM-1:6 complete all as specified and directed by Engineer-in-Charge.
Material & labour for glazed digital ceramic coloured tiles Ist quality in vertical surfaces such as in skirting and dados 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and icluding plaster 10mm thick in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material & labour for double charged/ultra charged vitrified ceramic polished light shade tiles 10mm thick area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM-1:6 complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item 23.00 above but in vertical surfaces such as dado, skirting and riser including rendering 10mm thick in CM 1:4 etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm each complete all as specified and directed by Engineer-in-Charge.
Supply & fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by Engineer-in-Charge.
Supply & fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening complete all as specified and directed by Engineer-in-Charge.
Supply & fix powder coated (not less than 50 micron thick) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix powder coated (not less than 50 micron thick) anodised aluminium frame or partitions for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix powder coated aluminium window with double side hung shutter for glazing and gauging and frame with one or more rebates made out of anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle and anodised aluminum fittings such as stay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) complete all as specified and directed by Engineer-in-Charge.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under above item shall be measured and paid separately .
Supply & fix powder coated anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grtade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @200 mm centre to centre, including the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminum standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge.
Material & labour for 1st HW plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix 35mm thick decorative type 1st lass hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
Supply & fix 300mm brass, sliding door bolt with sand die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix 300mm brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix 100mm butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed by Engineer-in-Charge.
Supply & fix 150mm size brass handles, cast type, polished bright complete all as specified and directed by Engineer-in-Charge.
Supply & fix 150 mm size aluminium, anodised barrel tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge.
Supply & fix 140mm floor door stopper of brass body and tongue with drawn steel spring complete all as specified and directed by Engineer-in-Charge.
Supply & fix 150mm size Aluminium handles, cast type, anodised complete all as specified and directed by Engineer-in-Charge.
Supply & fix 100mm butt hinges, butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new sufaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing 15mm bore (dia) and connections, segregating the serviceable pipes and connections, stacking properly at site(s) and keep in safe custody for re-use complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing 20mm bore (dia) and connections, segregating the serviceable pipes and connections, stacking properly at site(s) and keep in safe custody for re-use complete all as specified and directed by Engineer-in-Charge.
Material & labour for cutting chases, in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-Charge.
Supply & fix 20mm CPVC pipes ISI marked with all fittings fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of plain CPVC) complete all as specified and directed by Engineer-in-Charge.
Supply & fix 25mm CPVC pipes ISI marked with all fittings fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of plain CPVC) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs chromium plated fancy type bib taps 15mm bore, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair fancy type stop valve 15 mm bore chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair angle Valve 15 mm bore chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
Supply & fix table top rectangle shaped white matte basin WHB size 420x420x155mm) fixed in repair complete all as specified and directed by Engineer-in-Charge.
Supply & fix in sensor fauct for wash basin chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair 6mm thick frame less bevelled edge mirror fixed with steel stud complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair CP soap dish Make :Jaguar or equivalent make of Parriware /Hindware complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair CP soap dispensor with glass bottle Make :Jaguar or equivalent make of parriware /hindware(Cart Part No : CPR-1135) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair CP soap dish holder Make :Jaguar or equivalent make of Parriware /Hindware(Cart Part No : CPA-1131) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair toilet roll holder with flap fixed to walls with chromium plated screws complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair towel ring round Make: (Make : CAT Part No-ACN-1121BN of Jaguar series or equivalent make of hindware / parriware complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair towel rack 600mm long with lower hangars Make: (Make : Jaguar series or equivalent make of hindware / parriware.(CAT Part No : CPA-1181) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair glass self assembly(Make : Jaguar series or equivalent make of Parriware /Hindware complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair corner glass self (Make : Jaguar series or equivalent make of Parriware /Hindware Cart Part No : CPA-1173) complete all as specified and directed by Engineer-in-Charge.
Supply & fix CP hand shower (health faucet) with 1M flexible tube with 8mm dia wall hook with NRV (back flow preventor) Make : Jaquar or equivalent in Parryware, Cera (Cart Part No : ALD-565) complete all as specified and directed by Engineer-in-Charge.
Supply & fix grating square 150mm size of PTMT (minimum weight 100 gms ) complete all as specified and directed by Engineer-in-Charge.
Material & labour for PVC (SWR ) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for 75mm dia cast iron floor trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4 ) complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron,PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed by the Engineer-in-Charge of following bore of pipe:-
110mm bore
75mm bore
Supply & fix 110mm bore of pipe of PVC(SWR) drain self it pipes, single sockets ISI marked IS 13592 type 'B' in any length, jointed with solvent cement fixed in walls and the dia of pipes complete all as specified and directed by Engineer-in-Charge.
Supply & fix 110mm bore of pipe of PVC(SWR) drain self it pipes, single sockets ISI marked IS 13592 type 'B' in any length, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge of following bore of pipe:-
110mm bore
75mm bore
Supply & fix PVC(SWR) junction single 'Tee' ISI marked IS 14735 jointed with solvent cement fixed in walls and the dia of pipes complete all as specified and as directed by the Engineer-in-Charge of following bore of pipe:-
110mm bore
75mm bore
Supply & fix PVC(SWR) bend equal ISI marked IS 14735 jointed with solvent cement fixed in walls and the dia of pipes complete all as specified and as directed by the Engineer-in-Charge of following bore of pipe:-
110mm bore
75mm bore
Supply & fixing 1000 litre capacity rotational moulded polythelene water storage tank ISI marked, cylindrical vertical with closed top including dismantling existing water tank and removing to store complete all as specified and directed by Engineer-in-Charge.
Supply & fix rimless bowl with cistern for coupled WC with UF soft close seat cover , hinges, aual flush cistern fittings with back filling, fixing acessories size 385x680x785mm, P trap 180mm with all fittings complete Cart Part No :OPS-WHT-1573P1 80UFPMZ Make- Jaguar or euivalant series in Parriware/Hindware) complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, Insulation, etc.) or Insulation boards /blankets/slabs, any description and any thickness including cover fillets, cornices, etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing 12mm thick Gyp boards in ceilings fixed to ceiling sections with screws @ 300mm centre to centre and making good joints Gypsum binder including preparing the surfaces of ceiling boards and applying 2 coats of acrylic oil emulsion distemper with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofits at approxly 900mm centre to centre with GI cleats, GI suspenders and steel expansion fasteners with and including ceiling section of 0.55mm thick having kurled web of 50 mm and flange of 26 mm each side with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centrecomplete all as specified and directed by Engineer-in-Charge.
Supply & fix false ceiling corners with designed angular shape of size 100x100mm with POP fixed on 6mm thick fibre board with 20x20mm, 0.55mm thick galvanised sections fixed at intervals not more than 750mm complete all as specified and directed by Engineer-in-Charge.
Supply & fix solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed by Engineer-in-Charge.
Supply & fix 5 mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed by Engineer-in-Charge.
Material & labour for cement concrete 1:3:6 (using 40mm graded stone aggregate), 75mm thick as in plinth protection, etc., laid in alternate bays, finishing concrete surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for machine pressed precast concrete interlocking paver block any shape and size cofirming to IS 15658-2006 of 60mm thickness M35 grade with grey cemment and no pigments interstices filled with sand and bedded with and including 25mm thick sand cushion complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete in any position complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC block masonry built in cement mortar complete all as specified and directed by Engineer-in-Charge.
Material & labour for precast cement concrete block masonry type 1:3:6 using 20mm graded aggregate with solid blocks, exc 10cm in width and setting in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing precast cement concrete type B0 (1:2:4) using 12.5mm graded aggregate as in louvres and jallies, 25mm thick (measured solid) set cement moratar (1:4) including all mouldings complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
Dismantling stone slabs and tiles of laid bedded and pointed in any mortar any description or thickness in floors, aprons etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 20mm thick granite (Z black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm thick screed bed of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer-in-Charge. NOTE : Cost of Screed Bed shall deemed to be included in QUOTED UNIT RATE
Material & labour for dholpur stone pillar/column of roughly squared stones uniform colour of each of size 140x150x900mm, cut with machine cut edges dressed and fixed with CM complete all as specified and directed by Engineer-in-Charge.
Material & labour for dholpur sand stone jali railing thickness 20-25mm natutal polished ractangular shape uniform colour cut with machine cut edges dressed and fixed with polishing, rubbing & including silicon treatment complete all as specified and directed by Engineer-in-Charge.
Material & labour for dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm area and not exceeding 0.5 sqm fixed with and including one number SS clamps (grade -202) of flat 30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment ® complete all as specified and directed by Engineer-in-Charge.
Material & labour for reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded aggergate as in beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge. Note : Supply & fix reinforcement shall be measured and paid separately .
Material & labour for reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded aggergate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. Note : Supply & fix reinforcement shall be measured and paid separately.
Material & labour for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT bars 6 mm to 8 mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
Supplu & fix GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists etc in walls, ceilings, stanchions, beams etc including all laps, cutting and waste complete all as specified and directed by Engineer-in-Charge.
Pulling down the existing U/S wires of any type from concealed wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with or without conduit, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge.
Pulling out sub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and directed by Engineer-in-Charge.
Taking down main switch/DB’s including MCB’s with board and fixture of any description and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through existing conduit including provn of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with new plastic laminated white coloured top sheet cover 3.0 mm thick on existing sunken box complete all as specified and directed by Engineer-in-Charge for :-
One light point controlled by one, one way switch single pole piano type.
One Fan point controlled by one, one way switch single pole piano type.
One 3 pin 5 Amp socket outlet on the same board.
One 3 pin 5 Amps socket out let on independent board.
One bell point controlled by one bell push
All as per item No.101 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular plastic flush box of module 1/2 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular plastic flush box of module 3 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular plastic flush box of module 4 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular plastic flush box of module 6 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular plastic flush box of module 8 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of module 1/2 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of module 3 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of module 4 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of module 6 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of module 8 flush ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing including testing of storage type water heater/geyser of vertical type of capacity 25 Ltr, Rated 2000W,230V AC, 50Hz auto cutoff with a high tech adjustable thermostat,multifuction saftey valve,Magnesium anode coated heating element, rust proof external body with unique polymer protective coated inner tank, red and green indicator lamp, suitable for highrise building suitable for water pressure head upto 8 bars star rating (BEE) 5 STAR ,high density & thick PUF that ensures energy efficiency and reduced electricity bills ,15 Amps heavy duty plug complete all as specified and directed by Engineer-in-Charge Note:-The rate quoated shall be in including hanging of geyser in wall with 2/4 nos of stainless steel fastner of suitable size no extra payment will be allowed to contractor in this regard.
Supply & fixing CPVC pipes 20mm dia SDR-11 & plain CPVC SDR-11 with all fittings on wall/ceiling or laying in floor/wall complete with proper steel saddling of half meter apart of each complete all as specified and directed by Engineer-in-Charge
Supply & fixing quarter turn bib cock with flange,fancy type,cast brass with chrome finish crutch or butterfly handle ,screwed down ,screwed for iron pipe/CPVC Pipe or for brass ferrule and fixed for size 15mm bore complete all as specified and directed by Engineer-in-Charge
Supply & fixing quarter turn angle cock with flange 15 mm dia cast brass with chrome finish plate screwed down high pressure,fancy type,with long shank and cup(connected type),screwed both ends for iron pipe/CPVC Pipe complete all as specified and directed by Engineer-in-Charge
Supply & fixing Geyser PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge
Supply & fix PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge.
Taking down and re-fixing only ceiling fans including complete overhauling of the same complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of metal body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge. (Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). .
Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing caping/conduit medium grade ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge. (Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit)
Supply & fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building security light made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source including material and labour for suitable bracket made of 20 mm dia light grade GI pipe & MS clamps complete with nuts and bolts and washers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative with 2 core copper wire from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge
Supply and fixing in repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 core copper wire from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge
Supply & fix in replacement double door sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 triple pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement double door sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 8 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of isolators, MCBs, etc. In distribution board of the following rating and capacities complete all as specified and directed by Engineer-in-Charge :-
MCB TPN 415 volts 63 Amps Capacity, 10 KA
MCB SPN of 240 volts 20/32/40 Amps Capacity, 'C' series, 10 KA
MCB SP of 240 volts 5-40 Amps Capacity, 'C' series, 10 KA
Supply & fix in replacement, modular switch flush type, 6 Amp. SP, one way ,1 module complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement modular socket outlet, 3 pin, 6 Amp, flush type 2 module complete all as specified and directed by Engr-in-Charge
Supply & fix in replacement modular swicth, 16 Amp flush type 1 module complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement modular socket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement modular bell push, flush type, 6 Amp, 1 module complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of ceiling fan regulator 120 Watt 2 module Modular Type electronic step type 5 step 360 deg complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of ceiling rose 3 phase, PVC/ Polycarbonate body complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of LED Lamp, 7 W ,Type of capacity B22, wide operating Range 140V -280V, Input current 08mA- 30mA, lumen 180-300, UV and IR free light, color temperature 6500K, cool day light, up to 80 % Energy saving over GLS complete all as specified and directed by Engineer-in-Charge
Supply & fix in replacement recessed mounting LED 2'x2' luminaire with white acrylic flat light dissipater with LED light source of 40 Watt of size 2’x2’(Feet) square shape suitable for false/POP ceiling including cutting the existing POP ceiling and fixing complete all as specified and as directed by Eng-in-Charge.
Material & labour for applying two coats of Dr fixit dampguard classic or equivalent on newly plastered surfaces by mixing the base, hardener & water in the ratio 1:1:1 in order to get a brushable consisitency. The difference between application of two coats shall be 24 hours. Theoretical coverage for coating shall be 6 to 8 sqm per kg per coat complete all as specified and directed by Engr-in-Charge.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Material & labour for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulder complete all as specified and directed by Engineer-in-Charge.
Material & labour for 100mm thick PCC type D-2 (1:4:8) using (using 40mm graded stone aggregate) for sub base floor etccomplete all as specified and directed by Engineer-in-Charge.
Material & labour for 100 mm thick cement concrete (1:2:4), type B-2, using 4050 mm graded aggregate as in floors finishes complete all as specified and directed by Engineer-in-Charge.
Material & labour for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound of grade 'B' complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
Material & labour for MS framed work by fabrication such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railings frame work of water tanks etc including portions framed and hung as gates including pintle hinges, stop, hand-made sliding bolts etc conforming to Fe.290 Gde-E-165 complete all as specified and directed by Engr-in-Charge
Supply & fix expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members n exc 4 kg per sqm complete all as specified and directed by Engineer-in-Charge
Material & labour for preparing new or previously untreatedsteel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by Engineer-in-Charge. .
Material & labour for cement concete type B-01,1:2:4 mix (using 12.50 mm grade stone aggregate) as in copings including necessary form work complete all as specified and directed by Engineer-in-Charge.
Material & labour for 25 mm thick cement concrete type B-1,1:2:4 (using 20 mm graded stone aggregate) as in levelling course including water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
Supply only water proofing compound complete all as specified and directed by Engineer-in-charge.
BHAVANI PROVISION STORES (BID ID -3114477)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .