Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹4.4 Cr
EMD Value
₹8.9 L
Closing Date
30 Oct 2026, 2:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Superintending Engineer, Mechanical
Office of the Superintending Engineer, Mechanical
Establishing of central sterile supply department (CSSD) in GMC Rajouri at Associated Hospital, Kheora.
2026_PWDJK_327716_1
MHCJ/Tech/e-NIT/2026-27/10
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
180 days
GMC RAJOURI
As per ENIT
2 documents required · 2 mandatory
₹5,000
SE MECH AND HOSPITAL CIRCLE JAMMU
₹8.9 L
Office of the Superintending Engineer, Mechanical
10 Oct 2026
10 Oct 2026
31 Oct 2026
10 Oct 2026
30 Oct 2026
22 Oct 2026
10 Oct 2026 - 30 Oct 2026
17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Horizontal Rectangular High Pressure High Vaccum Double Door Sterilizer (AUTOCLAVE)
Should be ISI/BIS marked and manufactured as per IS No. 3829 (Part I) – 1978 and amendments till date, operating pressure 30 to 32 PSI corresponding to a temperature of 134 degree Celsius. The sterilizer chamber is to be formed out of SS 316, it’s jacket formed out of SS 304/316, jacket outer cover out of SS 304. The sterilizer will be provided with 2 Nos. pressure locking type hinged doors, door plate made out of SS 316 with shooting bolts flush mountings, steam generator made of SS 304, stand of the sterilizer made of SS 304/316.
The sterilizer will be automatic with PLC with 5 pre-sets programs and 1variable program MMI with DOT matrix printer wherein date time load identification no. cycle selected cycle parameter including time temperature and phase etc. can be seen and documented.
The sterilizer will also be provided with an intelligent transducer for heater protection.
The unit will be complete with vacuum pump and condenser and inter connecting pipeline. Sterilizer chamber size 600 mm x 600 mm x 1200 mm depth (20x20x40) suitable for electrical operation on 400/440 volts 3 phase AC supply electrical load 36 KW. | 4 | Nos | 100 | ₹400 |
| 2.01 | ETO Sterilizer – Fully Automatic
Ethylene Trioxide Gas Sterilizer using ethylene trioxide as a biocide to destroy bacteria, viruses, fungus and other unwanted organism. Ethylene oxide is used in sterilization of items that are heat and moisture sensitive such as anesthetic tubing and other plastic disposable materials etc.
The Chamber of size 12” x 12” x 48” (110 ltrs.) will be made of SS 316 for corrosion and gas resistant. The inner surface should be smoothly finished to minimize gas deposit.
Mode of heating - The Chamber will be heated with Strip air heater / Hot water circulated through the lumped coil of SS 304 around the chamber to maintain the chamber temp. at 40 – 75oC.
50 mm thick Resin bonded fibre glass covered with SS 304 outer cover.
The double door to be made of SS 316, hinged type with quick release locking arrangement with suitable safety interlocking so that the process cannot start unless the door is properly closed and cannot be opened during the process.
Paneling will be made of SS 304, Box type design, HMI-PLC will be located within the panel. As per SBD | 1 | Nos | 101 | ₹101 |
| 3.01 | Heat Sealing Machine
The continuous band heat-sealing machined with conveyer suitable for hospital sterile packing. It adapts electronic constant temp control system (temp control ). It has speed adjusting transmission mechanism (speed control). It can emboss upto 15 interchangeable characters for batch recording, date etc. (embossing mechanism). It can seal plastic film of various materials such as PE, PP, Aluminium foil etc. It has height adjustments as well as sealing width adjustments. As per SBD | 2 | Nos | 102 | ₹204 |
| 4.01 | Stainless Steel 316 Carriage suitable for Rectangular Sterilizer | 4 | Nos | 103 | ₹412 |
| 5.01 | Stainless Steel 304 Trolley suitable for above carriage | 8 | Nos | 104 | ₹832 |
| 6.01 | SS Control and Packing Table with drawer
This table is used for separation control and packing of various sets of sterilized goods for wards clinical operation theatres etc and is designed for standing and sitting workers. A removable hatch made of SS-304 is provided. The hatch contains a SS drawer and SS-304 plate size : 2000mm L x 1400mm W | 2 | Nos | 104 | ₹208 |
| 7.01 | SS Work Table with magnifying lamp
This table is used for wet goods with under shelf and examine the visible infectious element. The table top is fabricated out of 16 SWG SS 304 quality ground and polished to a smooth surface without high edge sections and also equipped with magnifying lamp. The table top frame is a complete assembly with front back and two ends welded together at corners overall size 1500mm x 610 x 890 HT | 4 | Nos | 104 | ₹416 |
| 8.01 | Pass Box
SS Dynamic Pass Box with HEPA filtration (class 100/ ISO 5) and UV sterilization lamp for transfer between clean and sterile zones. Size : 600 x600x600mm | 2 | Nos | 104 | ₹208 |
| 9.01 | SS Work Table with two sinks
The bench top is fabricated out of 16 SWG SS 304 qlty. ground and polished with smooth surface and edge section. The top is designed to give a stable work surface. The table top frame is a complete assembly with front back and two ends welded together. The sinks are made of stainless steel with inside ground and polished. Each sink is provided with a drain valve and a strainer on the bench top just above the sinks mixer for hot and cold water connection is provided. Overall size 2400mml x 650 mm w x 900mm HT | 3 | Nos | 104 | ₹312 |
| 10.01 | Washer Disinfector
Washer disinfector double door suitable for cleaning and disinfection of surgical instruments, anesthetic equipment, suction bottles, cleaning buckets, general circulation goods, dental tray and glassware, etc. with a fully closed washer disinfector fully automatic advanced micro processor which controls all services programming and statistic functions for safety reasons. The service and programming functions are coded.
The door would be provided with interlocking system, the chamber equipped with four spray arms which ensure good water penetration from all directions. Various attachments are provided to suit the load to be washed. Suitable dosage of detergent can be preset with the dosing pump. The provision of a double wall with insulation in between enables the washer disinfector to run with minimum sound and heat emission. The wash chamber inside the door, the pipework system and the circulation arms are made entirely of SS suitable for electrical operation on 400/440 volts 3 phase AC supply electrical load 13 KW capacity of 275 LTRS | 2 | Nos | 104 | ₹208 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
BOQ_1109241.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .