| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC SHOP NO 02 DADA COMPLEX NEAR DENA BANK NALIYA TAL ABDASA KUTCH GUJRAT 370 655 | KACHCHH | GUJARAT | 370655 | ₹17.3 L Quoted ₹18.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹23.0 L+₹4.9 L (27.2%)Rejected-AOC PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹23.0 L+₹4.9 L (27.2%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹23.8 L+₹5.7 L (31.5%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | ₹23.8 L+₹5.7 L (31.5%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹24.1 L+₹6.0 L (33.1%)Rejected-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | ₹24.1 L+₹6.0 L (33.1%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹24.2 L+₹6.2 L (34.1%)Rejected-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹24.2 L+₹6.2 L (34.1%) | L5 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Nov 2020, 6:00 pmClosed
GE (AF) Naliya NO 01
GE Air Force Station Naliya
REPAIR REPLACEMENT OF INTERNAL WIRING FITTINGS FIXTURES AND CONNECTED EARTHING ITEMS AT DOMESTIC AREA TECH AREA AT AF STN NALIYA
2020_MES_388464_1
8724/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Naliya NO 01
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No.01
₹60,000
Yes
3 Feb 2021
21 Oct 2020
23 Nov 2020
21 Oct 2020
21 Nov 2020
5 Nov 2020
21 Oct 2020 - 26 Oct 2020
Amount
Taking down copper/aluminum point wiring such as light, fan, socket or power complete and including fitting and fixture such as switches, socket, ceiling rose, pendent, regulators, light fittings, etc complete all as specified and as directed. NOTE:- Job includes for taking out old gutties,screws,nails,casing caping/conduit etc and making good the disturbed surface of wall,floor etc including to match with the existing surface
M & L for point wiring with 1.5 sq mm FRLS single core PVC insulated unsheathed 1100 V grade multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall / roofs ceiling etc and including provision of 1.5 sq mm FRLS single core PVC insulated unsheathed 1100 V grade multistranded copper conductor as earth continuity conductor and connected to common earth dolly including PVC box ISI marked of suitable size for mounting the switches, socket outlets, fan regulators etc complete all as specified and as directed for One light / Fan point controlled by one switch.
All as per item No. 2 above but One socket 3 pin outlet 5 amp on independent board.
All as per item No. 2 above but One light point controlled by two 2-way switches.
All as per item No. 2 above but One 3 pin socket outlet 5 amp on the same board with other switches.
All as per item No. 2 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size
All as per item No 2 above but with copper conductor cable for one 3 pin socket outlet 15 amp on independent board with 2.5 sq mm copper cable including earth continuity conductor.
S & F in replacment of switch piano flush type single pole one way 5 amp complete all as specified and as directed.
S & F in replacment of switch piano flush type single pole two way 5 amp complete all as specified and as directed.
S & F in replacment of ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified and as directed.
S&F in replacment of switch socket combination 2 in 1, 3 pin 5/15 amp flush type complete all as specified and as directed.
S&F switch socket combination 2 in 1,5 amp flush type complete all as specified and as directed.
S&F in replacment of socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type complete all as specified and as directed.
S&F in replacment of MCB DB SPN 8 ways double door vertical type with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking out old DBs of any type and capacity and making good to match with the existing surface of wall complete all as specified and as directed.
All as per item No. 14 above but 4 way
S&F in replacment of sheet metal enclosure 4 ways double door triple pole and neutral with 415 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking out old DBs any type and capacity and making good to match with the existing surface of wall complete all as specified and as directed.
S&F in replacment of vertical type DB ,double door Suitable for isolated neutral bar 4 ways,IP 43 protection, Door earthing,mechanical impact strength IK 08 insulated busbar assembly, fixed in the wall with suitable nut and bolt including 4 pole MCCB 25 Amp 16 KA fixed in DBs as incommer three phase supply fixed in the wall including taking out old DBs any type and capacity and making good to match with the existing surface of wall complete all as specified and as directed
S&F in replacment of Isolator 4 pole 100 amp complete all as specified and as directed
S&F in replacment of Isolator 4 pole 63 amp complete all as specified and as directed
S&F in replacement of MCB single pole and neutral 35-63 amps, 240 Volts, Complete all as specified and as directed.
S&F in replacement of MCB 6 to 32 amps single pole 240 Volts, Complete all as specified and as directed.
S&F in replacement of switch bell push, flush type 5 Amp complete all as specified and as directed
S&F in replacement of bell, AC, 230 Volts single pole complete all as specified and as directed
S&F in replacement of lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified & as directed.
S&F LED Batten for LED tube light with 01 Nos of LED tube 18 Watt fixed on two Nos of Square Block with twin core copper flexible wire and incl taking down old type tube light fitting etc complete all as specified and as directed.
S&F LED plastic batten with white acrylic cover fixed on two Nos of Square Block with twin core copper flexible wire and including taking down old type tube light fitting/holder any type etc complete all as specified and as directed.
S&F in replacement of energy efficient conventional LED Bulk head fitting 10 W IP 65 including twin core copper flexible wire and including taking down old type fitting/holder any type etc complete all as specified and as directed.
S&F in replacement of LED street light fitting 15 W with pressure die cast housing along with prismatic polymer carbonate diffuser and LED with secondry optic with IP 65 protection, including provision of GI pipe light grade of suitable size bent to the shape fixed in the wall with two nos of clamps,nut,bolts,screw etc and taking down old unserviceable street light fitting any type complete all as specified and as directed.
S&F in replacement of fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
S&F in replacement of LED Post top lantern warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection, including provision of suitable size of GI pipe medium grade and suitable length as required on the site fifed on the existing pillers by welding of four Nos of leg and fixed by using fastner and nut and bolts and neccessary connection with twin core copper cable multistranded 1100 volt grade,complete all as specified and as directed.
S&F in replacement of 9 Watt LED bolard in rectangular shaped victorian design with opal acrylic diffuser and IP 65 protection,including PCC work for mounting the fittings with suitable size of nut,bolts and connection with two core Copper cable complete all as specified and as directed.
S&F in replacement of 30W LED recessed 2x2 luminaire fixed in the existing Ceiling/roofs white powder coated CRCA housing with LED seamless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size complete all as specified and as directed.
S&F in replacement of 15W LED downlight sleek square recessed 1'x1' luminaire fixed in the existing Ceiling/roofs with aluminium die cast body finish with drop down PC diffuser to drive low glare illumination with optimized heat shrink for efficient heat dissipation and necessary connection with twin core copper cable of suitable size complete all as specified and as directed.
S&F in replacement sub main wiring drawn through PVC casing caping of suitable size with all fittings two run of single core 6 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 6 sq mm FRLS as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit and all accessories complete all as specified and as directed Note : Three runs of cable and one run of conduit shall be measured and one unit.
S&F in replacement sub main wiring drawing through PVC casing caping of suitable size with all fittings two run of single core 4 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor and one run of 4 sq mm FRLS as earth wire of multistranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade including taking down old unserviceable sub main wire any size with casing caping/conduit complete all as specified and as directed Note : Three runs of cable and one run of conduit shall be measured and one unit.
M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary excavation, RFR, Removal with, providing RCC 1:2:4 type B1 with 40mm thick RCC cover with 6mm dia MS rods as in reinforcement at 150mm c/c both ways including testing on completion.
Checking and attending complaints by means of repairing / rectifying the electric defects / faults related to elctrical equipments,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and as directed. Note : 1 The electrician deployed by the contractor shall have ITI / 05 years experience certificate in concerned trade. Helper deployed shall be min 8th pass with minimum 03 years experience in relevant trade. 2. Item to be replaced under this item shall be under contractors supply under respective items of this schedule. 3. Minor items such as PVC wire of any size as per requirement up to 1.0m length,thimble,electric tape etc shall be deemed to be included in the quoted rate of this item. 4.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time notified in the complaint slip failing which a penalty @ Rs.20 per complaint per day shall be leivied / imposed on the contractor and recovery shall be made from his dues. 5. Contracror shall arrange suitable T&P including necessary from work and scoffolding and safety measures to make it functional complete all as specified and as directed. 6. Contractor or his representative shall report daily at complaint cell for collection of complaints from the concerned JE's incharge,in case after checking & attending the defects, if it is fount not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engeer in charge by the contractor / his representative immediately. If Engr -in -chargr is satisfied with contractor's view, no recovery shall be made on this account.
Supply only Switch socket combination 6/16 A 250V AC universal with box in polycarbonate complete all as specified and directed.
Supply only switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
Supply only socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
Supply only electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
Supply only replacement of capaciator 2.50 Mfd, 240 V complete all as specified and directed.
Supply only Hylem sheet 3 mm thick size 9'' x 11'' including cutting of switch,socket complete all as specified
Supply only Hylem sheet 3 mm thick size 8'' x 5'' including cutting of switch,socket complete all as specified
Supply only of Isolator 4 pole 100 amp
Supply only Isolator 4 pole 63 amp
Supply only MCB single pole and neutral 35-63 amps, 240 Volts, Complete all as specified and directed.
Supply only MCB 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
Supply only switch bell push, flush type 5 Amp.
Supply only bell, AC, 230 Volts single pole.
Supply only lamp holder, insulated body with back plate batten/angle type for batten fitting complete all as specified & directed.
Supply only moduler switch 1 way 6A 1 module
Supply only moduler bell push 6 A, 1 module
Supply only moduler socket 6 A, 2/3 pin,2 module
Supply only moduler socket 6A/16A, 2/3 pin combined,2 module
Supply only moduler fan regulator 120 W. 2 module
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep. Including taking down old unserviceable board any type and removing the all unsv swinches sockets etc all as directed.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 200mmx150mmx50mm deep. Including taking down old unserviceable board any type and removing the all unsv swinches sockets etc all as directed.
Supply only PVC rectangular block for mounting switches, sockets,fan regulator,etc with 3 mm thick plastic laminated sheet cover of size 350mmx300mmx50mm deep. Including taking down old unserviceable board any type and removing the all unsv swinches sockets etc all as directed.
Supply only rigid non metalic PVC conduit including of boxes(Junction/terminal) all tees,bends,elbow,reducer,bell mouth,tubes ends and fixture accessories such as couplers lock nuts saddles pipe hooks etc 25 mm dia
Supply only LED tube 18/20 watt including taking down old Unsv led tube from the existing fitting all as directed
Supply only bipin holder suitable for 28/36/40 watt tube light fitting
Supply only electronic ballast 36/40 watt fitting including taking down of old unsv tube rod all as directed.
Supply only LED driver suitable for 25 Watt post top lantern all as specified and as directed
Supply only LED lamp suitable for 45 Watt post top lantern all as specified and as directed
Supply only LED driver suitable for 16 watt garden light all as specified and as directed
KALIKAY ENTERPRISES
M/s. Shree Shakti Enterprise
NILESH SUBHASH KARALE
Vijay Construction Co
Krishna Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .