Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹32.7 L Quoted ₹33.8 L | L1 | Accepted-AOC LOWEST TENDER |
| 2 | L2₹38.2 L+₹4.4 L (12.9%)Rejected-Finance D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹38.2 L+₹4.4 L (12.9%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹41.9 L+₹8.1 L (23.8%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹41.9 L+₹8.1 L (23.8%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹42.9 L+₹9.1 L (26.8%)Rejected-Finance MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹42.9 L+₹9.1 L (26.8%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹43.0 L+₹9.1 L (27.0%)Rejected-Finance | ₹43.0 L+₹9.1 L (27.0%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jan 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
COMPLETION OF INCOMPLETE WORK UNDER RISK AND COST FOR REPAIR/ MAINTENANCE OF FIRE FIGHTING SYSTEM UNDER AGE E/M NO.I OF GE (UTILITY-II) VISAKHAPATNAM
2019_MES_306722_1
8674
Open Tender
Electrical Maintenance Service
Item Rate
180 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹80,000
Yes
10 Feb 2020
31 Dec 2019
21 Jan 2020
31 Dec 2019
20 Jan 2020
14 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth and getting out soft / loose soil for laying of cables, pipes etc, complete all as specified and directed by Engr-in- Charge.
Returning filling in, including spreading levelling watering and well ramming in layers n.exc. 25 cm thick.
Removing excavated soil to a distance n.exc. 50 m distance and depositing where directed at a level n.exc 1.5 m above the starting point.
M&L for cutting the road/ PCC path of 230 mm width and 300 mm depth and making good the disturbed surface with concrete complete all as specified and directed by Engr-in- Charge. Note: Concrete required for filling the road cutting shall be measured and paid separately.
M&L PCC 1:3:6 type C1 (using 20 mm graded granite stone aggregate) as in coping, bed plates including necessary formwork complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B1 (using 20 mm graded granite stone aggregate) as in pavements, making good for disturbed portions etc, complete all as specified and directed by Engr-in-Charge.
Supply and replacement of MS ERW heavy grade pipe 200 mm bore, thickness not less than 5.40 mm laid in trenches etc, vertically with welded joints and including preparation and applying two coats of synthetic enamel paint over a coat of zinc chrome primer in open places and with bitumen coating / felt cover in trenches, testing / commissioning complete all as specified and directed by Engr-in-Charge.
All as per Sl. item No. 7 above but for 150 mm bore.
All as per Sl. item No. 7 above but for 100 mm bore.
All as per Sl. item No. 7 above but for 80 mm bore, thickness not less than 4.80 mm
All as per Sl. item No. 7 above but for 65 mm bore, thickness not less than 4.80 mm
Supply and replacement of fire brigade inlet connection 4 way including with accessories complete all as specified and directed.
Supply and replacement of fire brigade inlet connection 2 way including with accessories complete all as specified and directed.
Supply and replacement of fire hydrant landing valve gun metal, type 'A' (Single head outlet) of 63 mm bore conforming to IS-5290 complete all as specified and directed.
Supply and replacement of fire hydrant landing valve gun metal, type 'B' Double head outlet) of 63 mm bore conforming to IS-5290 complete all as specified and directed
Supply and replacement ABS plastic 3/4" shut off nozzle suitable for 19/20mm hose complete all as specified and directed
Supply and replacement 100 mm dia CI flanged stainer for suction complete necessary nuts, bolts, gasket etc., complete all as specified and directed
Supply and replacement 150 mm dia CI flanged stainer for suction complete necessary nuts, bolts, gasket etc., complete all as specified and directed
Supply and replacement of cast iron double flanged sluice valves of size 150 mm bore, PN-1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle complete all as specified and directed by Engineer - in - Charge.
All as per Sl. item No. 19 above but of 100 mm bore
All as per Sl. item No. 19 above but of 80 mm bore
Supply and replacement of cast Iron double flanged end, non return valve PN- 1.6, 150 mm bore, conforming to IS complete all as specified and directed.
Supply and replacement of cast Iron double flanged end, non return valve PN- 1.6, 100 mm bore, conforming to IS complete all as specified and directed.
Supply and replacement of cast Iron double flanged end, non return valve PN- 1.6, 80 mm bore, conforming to IS complete all as specified and directed.
Supply and replace existing pressure guage 4" dial, 0-14 Kg rating complete all as directed by Engr-in-charge.
Supply and replace existing pressure guage 8" dial, 0-21 Kg rating complete all as directed by Engr-in-charge.
Supply and replacement of hose reel of 19mm dia and 30 metre length conforming to IS-444 (1980) including shutoff valve and 4.6 mm dia nozzle as per IS-8090(1976) complete all as specified and directed.
M&L for arresting the leakage in junction box including replacement of rubber gasket, connecting hose with clamps, bolts etc., removing and refixing the hydrant valve, necessary welding works as per site requirement complete all as specified and directed.
Supply and replacement of Spindle of 100 mm dia sluice valve made out of EN-8 steel with check nut made out of MS/CI and including replacing perished gland packing, rubber gasket, bolts and nuts complete all as specified and directed by Engr-in-Charge:-
Supply and replacement of Spindle of 150 mm dia sluice valve made out of EN-8 steel with check nut made out of MS/CI and including replacing perished gland packing, rubber gasket, bolts and nuts complete all as specified and directed by Engr-in-Charge:-
Repairs/ servicing of fire hydrant landing valve type A/B of 63 mm dia, including spindle threading, replacement of washers, checknuts, packing serving to arrest leakage and proper functioning of valve complete all as specified and directed.
Supply and replace MCCB 4 pole 100/125 Amps, 50 Hz, 415 Volts with breaking capacity 25 KA complete all as specified and directed
Taking down existing induction motor of above 20 upto 30 HP capacity 3 phase, 415 Volts, 50 cycles AC from foundations bed / coupling, opening the motor, taking to workshop and removing the burnt windings, cleaning the stator and rotor with cleaning agent rewinding the motor with appropriate gauge of super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of motor with suitable packing materials and connecting to the pump, testing the motor to satisfactory performance complete all as directed by Engineer-in-charge.
All as per SL item No.33 above but 10 to 15 HP capacity.
All as per SL item No.33 above but above 5 to 10 HP capacity.
All as per SL item No.33 above but upto 5 HP capacity.
M & L for carrying 'B' check of 4 cylinder 85 to 105 BHP Diesel engine set for periodical checking and preventive maintenance as per manufacturer's instructions including replacement of necessary recommended filters, Engine Oil and applying one coat of synthetic enamel paint complete all as directed.
Removing the fuel pump and injectors of Kirloskar Cummins 4 cylinder 85 to 105 BHP Diesel engine set, Servicing the pump, overhauling and calibrating the injectors, fixing back, connecting, priming and commissioning the engine including replacing rocker cover gaskets etc., complete all as directed.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe- 410 (grade -E250) quality 'A' complete all as directed.
Cleaning of static water tank of 25000 litres capacity and including by pumping out the accumulated water in the bottom using pumpset, removing the complete sludge by suction process using either suction pump or vaccum process, cleaning the walls ceiling & floor using high pressure water jet to dislodge all the mud, dirt algaue, fungus and layers of calcinations, vaccum cleaning to remove the dislodged waste, cleaning with bleaching powder on walls / floor of the sump to make it sterilise and take care of any further suspend bacteria, viruses which might have remained in the tank without disturbing the water suply to the area including painting the details of sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire tank internal and external complete all as specified and directed by Engr-in-Charge.
Labour only for attending break down of CI/MS pipe line of 150 mm dia bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering complete all as specified and directed by Engr-in-Charge, for the following sizes:- Note 1 :- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- Earth work, Lead joints, Supply only CI/ DI/ MS pipes, specials, fittings will be measured and paid seperately under relevant items.
All as per SL item No.41 above but 100/80 mm dia.
Supply only MS ERW pipe 150 mm bore, thickness not less than 5.4 mm, vertically with welded joints including making leak proof joints complete.
All as per SL item No.43 above but of 100 mm bore
All as per Sl. item No.43 above but for 80 mm bore thickness not less than 4.8 mm
Supply and replacement of single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single fire hydrant valve and testing complete all as specified and directed by Engineer - in - Charge.
M&L preparation of steel surfaces and including applying two coats of synthetic enamel paint over a coat of red oxide primer on MS fire fighting pipe 150 mm bore complete all as specified and directed by Engineer - in - Charge.
All as per Sl. item No. 47 above but of 100 mm bore
All as per Sl. item No. 47 above but of 80/63 mm bore
M&L for preparation and applying spray painting of existing colour for electric driven pumpset of 10 HP capacity complete all as specified and directed by Engineer - in - Charge.
M&L for preparation and applying spray painting of existing colour for electric driven pumpset of 12.5 to 40 HP capacity complete all as specified and directed by Engineer - in - Charge.
M&L for preparation and applying spray painting of existing colour for electric driven pumpset of 45 to 100 HP capacity complete all as specified and directed by Engineer - in - Charge.
Supply and replacement of CP hose 15 metre complete all as specified and directed.
Supply and fix 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to iron pipe complete including taking down old unserviceable all as specified and directed by Engr-in-Charge.
All as per SL item No.54 above but of size 25 mm dia.
Supply and replacement of 63 mm bore gun metal nozzle conforming to IS-903 complete all as specified and directed by Engineer - in - Charge.
Supply and replacement of Branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed by Engineer - in - Charge.
M&L masonary valve chamber of size 1200x1200x1200 mm (internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 5 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unservicble compete all as specified and directed by Engr-in-Charge.
All as per Sl. item No. 58 above but of size 900x900x900 mm (internal dimensions)
All as per Sl. item No. 58 above but of size 600x600x600 mm (internal dimensions)
Supply and replace gland packing suitable for pumpsets of 60 to 100 HP capacities to arrest the leakages complete all as specified and directed
Supply and replace gland packing suitable for pumpsets upto 50 HP capacities to arrest the leakages complete all as specified and directed
Supply and replace MCCB 4 pole 250 Amps, 50 Hz, 415 Volts with breaking capacity 36 KA complete all as specified and directed
Supply and replace MCCB 4 pole 160-200 Amps, 50 Hz, 415 Volts with breaking capacity 36 KA complete all as specified and directed
AYYAPPA CONSTRUCTIONS
M/S CHANDRA ENGINEERS AND CONTRACTORS
SRI SURYA PROJECTS
Sri Surya Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .