Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BID |
| 2 | L2₹1.3 Cr+₹5.3 L (4.38%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹1.3 Cr+₹5.3 L (4.38%) | L2 | Rejected-Finance HIGHER BID |
| 3 | L3₹1.8 Cr+₹58.6 L (48.5%)Rejected-Finance PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹1.8 Cr+₹58.6 L (48.5%) | L3 | Rejected-Finance HIGHER BID |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT RECOMMENDED DUE TO NOT FULFILL THE CRITERIA AS PER NIT CONDITION FOR OPENING OF F BID |
| Sl No | Description | Qty | Unit | M/s Bombay Novelty Stores L1 | Abhishek Enterprises L2 | M/S S. SINGH TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) including aluminium framework for fixing of ACP used in ceilings with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawing and complete all as specified and directed.
Note : 1. Section of aluminium will be very as per ground requirement.
2. If sliding window/ openable window both for sliding channel and another section will be paid under this item. | 487.5 | Kg | 550 ₹2,68,125 Lowest | 650 ₹3,16,875 | 650 ₹3,16,875 |
| 2.00 | M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawing and all as specified and directed. | 118 | Kg | 550 ₹64,900 Lowest | 650 ₹76,700 | 650 ₹76,700 |
| 3.00 | S&F 12mm thick Toughned glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed
Note : 1. SS Clips as required size with screw-02 Nos for each shutter.
2. SS handle 250mm long 02 Nos for each shutter.
All as above fitting and fixtures deemed in quoted rates including brackets for arresting glass etc. complete all as specified and directed. | 32 | Sqm | 2,600 ₹83,200 | 2,475 ₹79,200 Lowest | 2,500 ₹80,000 |
| 4.00 | M&L for 4mm thick ESD Epoxy floor system incl surface preparation and application of epoxy primer upto 100 microns, epoxy screed 1.8mm thick on primer surface, epoxy conductive primer 100 microns, 50mm wide copper tape and grid of copper tape from 0.6mx0.6m to 2mx2m(as required) with thickness of copper tape 1mm-3mm(as required) including coving, ESD Epoxy top coat with pigments 2mm thick final coat, resistivity 10^6 to 10^9 Ohms, ESD reading testing complete all as specified and directed. | 123 | Sqm | 3,250 ₹3,99,750 Lowest | 4,230 ₹5,20,290 | 5,500 ₹6,76,500 |
| 5.00Supply & installation standard wall partitions are a composite construction of two skins of 0.6mm PCGI the self supporting internal walls are constructed with an GI frame work. The partition seams are sealed by silicon with a perfectly flush finishing. PUF infill insulation materials is sandwiched between the two skin layers and sealed from the exterior by the PUF density-43+2 Kg/m3 with following thickness complete all as specified and directed | ||||||
| 5.01 | 80mm thick Panels | 117 | Sqm | 3,200 ₹3,74,400 Lowest | 3,256 ₹3,80,952 | 5,500 ₹6,43,500 |
| 5.02 | 50mm thick Panels | 20 | Sqm | 2,900 ₹58,000 Lowest | 3,150 ₹63,000 | 6,000 ₹1,20,000 |
| 6.00 | Supply & installation, testing & commissioning return Air riser panel 80mm thick standard wall partitions are a composite construction of two skins of 0.6mm PCGI the self supporting internal walls are constructed with an GI frame work. The partition seams are sealed by silicon with a perfectly flush finishing. PUF infill insulation materials is sandwiched between the two skin layers and sealed from the exterior by the PUF density-43+2 Kg/m3, includes SS perforated sheet, volume control damper and 20u filter complete all as specified and directed | 21 | Sqm | 4,900 ₹1,02,900 Lowest | 5,100 ₹1,07,100 | 9,000 ₹1,89,000 |
| 7.00 | Supply and fix 80 mm thick view panels (View glass Size : 1000x1000MM) (0.5 MM/ 0.5 MM) complete all as specified and directed | 2 | Each | 21,500 ₹43,000 | 19,000 ₹38,000 Lowest | 20,000 ₹40,000 |
| 8.00 | Supply and fix false ceiling panels are designed to fit within each other and suspended by threaded tension bars with adjustable turnbuckles fastened to the overhead support at fixed intervals , Standard ceiling panels are 50mm thick and have a composite construction of two skins of PCGII over an GI frame work with a sealed and insulated interior, 50mm double skins non walkable false ceiling made of 0.6mm both top and bottom plain PCGI sheets with mounting accessories and PUF in fill, PCGI type, 50 mm thick ceiling panels (0.6 MM/0.6MM) complete all as specified and directed | 60 | Sqm | 3,100 ₹1,86,000 | 3,050 ₹1,83,000 Lowest | 52,500 ₹31,50,000 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
21 Oct 2025, 6:00 pmClosed
GE ARMY
BHUJ
PROVN OF EXTERNAL SERVICES AT 996AD REGT AT MIL STN BHUJ UNDER GE ARMY BHUJ
2025_MES_731568_1
8367
Open Tender
Civil Works
Item Rate
120 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE ARMY
₹2.0 L
Yes
27 Dec 2025
18 Sept 2025
23 Oct 2025
18 Sept 2025
21 Oct 2025
9 Oct 2025
Amount
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) including aluminium framework for fixing of ACP used in ceilings with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawing and complete all as specified and directed. Note : 1. Section of aluminium will be very as per ground requirement. 2. If sliding window/ openable window both for sliding channel and another section will be paid under this item.
M&L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawing and all as specified and directed.
S&F 12mm thick Toughned glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed Note : 1. SS Clips as required size with screw-02 Nos for each shutter. 2. SS handle 250mm long 02 Nos for each shutter. All as above fitting and fixtures deemed in quoted rates including brackets for arresting glass etc. complete all as specified and directed.
M&L for 4mm thick ESD Epoxy floor system incl surface preparation and application of epoxy primer upto 100 microns, epoxy screed 1.8mm thick on primer surface, epoxy conductive primer 100 microns, 50mm wide copper tape and grid of copper tape from 0.6mx0.6m to 2mx2m(as required) with thickness of copper tape 1mm-3mm(as required) including coving, ESD Epoxy top coat with pigments 2mm thick final coat, resistivity 10^6 to 10^9 Ohms, ESD reading testing complete all as specified and directed.
Supply & installation standard wall partitions are a composite construction of two skins of 0.6mm PCGI the self supporting internal walls are constructed with an GI frame work. The partition seams are sealed by silicon with a perfectly flush finishing. PUF infill insulation materials is sandwiched between the two skin layers and sealed from the exterior by the PUF density-43+2 Kg/m3 with following thickness complete all as specified and directed
80mm thick Panels
50mm thick Panels
Supply & installation, testing & commissioning return Air riser panel 80mm thick standard wall partitions are a composite construction of two skins of 0.6mm PCGI the self supporting internal walls are constructed with an GI frame work. The partition seams are sealed by silicon with a perfectly flush finishing. PUF infill insulation materials is sandwiched between the two skin layers and sealed from the exterior by the PUF density-43+2 Kg/m3, includes SS perforated sheet, volume control damper and 20u filter complete all as specified and directed
Supply and fix 80 mm thick view panels (View glass Size : 1000x1000MM) (0.5 MM/ 0.5 MM) complete all as specified and directed
Supply and fix false ceiling panels are designed to fit within each other and suspended by threaded tension bars with adjustable turnbuckles fastened to the overhead support at fixed intervals , Standard ceiling panels are 50mm thick and have a composite construction of two skins of PCGII over an GI frame work with a sealed and insulated interior, 50mm double skins non walkable false ceiling made of 0.6mm both top and bottom plain PCGI sheets with mounting accessories and PUF in fill, PCGI type, 50 mm thick ceiling panels (0.6 MM/0.6MM) complete all as specified and directed
Supply & installation of extruded aluminium powder coated clips on type coving for entire wall to wall and ceiling R50, coving considered for ceiling to ceiling wall to wall and wall to ceiling only (for new walls and ceiling panels only) complete all as specified and directed
R50 Coving
3D Corner
80mm Bottom track
50mm Bottom track
R90 Outer corner vertical profile
R90 Outer corner radius 2D
Supply and fix modular skin wall or panel mounted clean room doors made of 45mm thick PUFF insulated panels GIPC outer and inner skin with Doorset make SS Hinges, Door Closer (T68), Mortice Lock set, Euro Cylinder, Push plate SS-304, D Handle -SS-304 19 mm Dia 254 mm, Glass clear 6mm thick W745 X H345, 3mm Tape, Silicon Tube, Hardware Nuts and Bolts, Fisher Screw, Kick Plates complete all as specified and directed
M&L for cutouts (Qty will be finalised after approval of drawings) factor made cutouts in ceiling panels & walls for light fixtures, supply air modules, magnehelic gauges & electrical conduits complete all as specified and directed
S&F socketed round UPVC conduit of size 25mm medium grade, fire retardant and corrsion free all as specified and directed.
S&F socketed round UPVC conduit of size 32mm medium grade, fire retardant and corrsion free all as specified and directed.
M&L for point wiring with using 1.5 Sqmm (nominal area) with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML No in and including medium grade, PVC conduit and it connected accessories, ISI marked with valid CML with modular sunken box externally covered with modular cover and plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and dircted for the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISI marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter and not by chiselling. 6.Including removing old unservicable wiring and finishing the surface to match with the existing surface. 7. Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
One light/buzzer point controlled by one; one way switch.
Supply and fix ceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specified and directed.
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 36/40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light,6000K complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core 0.5 sqmm flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-charge
S&F tripple pole and earthing enclosure (Industrial type) with a three pin and earth plug with socket with one tripple pole MCB of capacity 32 Amp. complete all as specified .
M/L for Sub main wiring with 4 runs + 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 16 Sqmm drawn through PVC concealed conduit in stone masonry/brick masonry including accessaries with 16sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc and connecting up and complete all as specified and directed. Note: 6 runs of cable and concealed PVC conduit will be measured as one RM length.
S&F sheet metal enclosures for distribution board suitable for MCCB as incommer MCCB of 160A to be used VTPN ( Triplepole and neutral ) 12 way, 415Volts, sheet metal powder coated, IP 42 protection with 250 Amps rated copper bus bar, double door type including MCB TP complete all as specified and directed.
S&F MCCB 4 Pole , 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA omplete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of rating 40 to 100 Amps TPN complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning of rating 6 to 32 Amps SP complete all as specified and directed.
S&F sheet metal enclosures for distribution board suitable for MCCB as incommer when MCCB 100A to be used VTPN ( Triplepole and neutral ) 4 way, 415Volts, sheet metal powder coated, IP 42 protection with 160 Amps rated copper bus bar, double door type including MCB TP complete all as specified and directed.
S & F MCCB 4 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA omplete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of rating 16 to 32 Amps TPN complete all as specified and directed.
Supply install testing,commissioning of CRI tested Copper earthing electrode of length 3 metres, 40mm dia and back fill compound of 50kgs ,and conductive gel to retain moisture should be filled layer wise and inter connceted by exothermic brazing & copper wire of should be suppllied and fix upto testpoint protected by GI pipe of size 50mm dia up to test point and fix to chemical earthing, PCC earth pit of standared size as per SSR part-1 and submmision of earth results and painting of Date of test , value obtain at site and all specified and as directed. Note : If desirable result not found through earthing the another earthing with desirable result shall be done by the contractor on its own cost.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 95Sqmm 3core and all as and complete all as specified and directed.
Supply & fix XLPE insulated, armoudred heavy duty electric cables with aluminium conductirs of 1100 V grade cross section area 300 Sq mm 3.5 Core and complete all as specified and directed.
Supply & fix XLPE insulated, armoudred heavy duty electric cables with aluminium conductirs of 1100 V grade cross section area 240 Sq mm 3.5 Core and complete all as specified and directed.
Supply & fix XLPE insulated, armoudred heavy duty electric cables with aluminium conductirs of 1100 V grade cross section area 35 Sq mm 3.5 Core and complete all as specified and directed.
Supply & fix XLPE insulated, armoudred heavy duty electric cables with aluminium conductirs of 1100 V grade cross section area 25 Sq mm 4 Core and complete all as specified and directed.
Supplying, install and errect in true vertical position pressed concrete poles of 11.00 mtr long 152mm x 152mm at top and 152mm x 260mm at bottom,class 9, painting and marking alternate white and black strip 30cm height, painting pole number, letters/figures by black paint complete all as specified and directed.
Material and labour for lightning arresters nominal discharge current Peak 65 KA rating, suitable for operation on HT 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-in forced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for withstanding from the effects of pollution, rain, heat etc, and with moisture seal , stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements,all as specified and as directed. Make-Bhel/Jaipurya brothers/National.
Supply and fix HT 11KV outdoor type mechanically operated air break switch suitable for vertical mounting fixed type with GI operating rod of suitable length and size complete on 12 porcelain insulator of rating upto 400A 11000V along with lock arrangment ,MS clamp, Bolts, Nuts, and washer etc and also including dropout explusion type fuse , rating suitable fuse ,including paint over a coat of red oxide primer on MS work complte all as specfied and directed.
Supply, install, testing and commissioning of Transformer step down,11/0.433 KVA, complete outdoor, copper wound of capacity 250KVA, level-2, compliance to IS 1180 (ammendment No 4). Including staging of transformer as shown in technical drg of HQ Jodhpur Zone. Complete all as specified and directed .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Excavation in trenches exceeding 1.5m wide and not exceeding 3.0m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
Supplying and laying un-reinforced precast concrete cable cover, class HV Type I, flat, size 300 mm x 180 mm x 40 mm. laid in trenches complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and as directed .
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and as directed .
Supply and erection of Cross arms, bracings, supports, clamps and back plates,equal channel, anchor for stay wire,stay strand fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed all as specfied and directed
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron lead of 4 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix All aluminium conductor having high strength to weight ratio for jumper of 2/4 pole structure complete all as specified
Supply and connection of new Pin type, porcelain, vitreous,brown insulator on pole or any structure including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 voltsgrade all as specfied and directed.
Supply and conncetion Disc type insulator, porcelain, vitreous145mm high and 255mm dia ball and socket type, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts grade including connection of existing OH HT line all as specfied and directed .
S&F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 50 KVA and complete all as specified and directed.
Supply and fix UPS for 60 min back up three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 7.5KVA including neceesary connction with existing system all as specfied and directed .
Supply and fix UPS for 60 min back up three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 5KVA including neceesary connction with existing system all as specfied and directed .
Supply and fix UPS for 60 min back up single phase AC input 190 to 260V and out put 220 V ± 1% of capacity 5KVA including neceesary connction with existing system all as specfied and directed. Note : For item No 56 to 58 : Connection of UPS required in light/fan and testing socket/ equipments. All cost of necessary wiring for these point/ required point and battery bank for desire capacity/ time shall be included in quoted rates and nothing extra will be paid.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with star rating and EER 3.2 of capacity 2.0 and complete all as specified and directed. Note : All items/spares required to fix/Install the AC's such as compressor stand, drill in walls, nuts, bolts, clamps etc shall be deemed to include in quoted rates. Nothing extra shall be paid on this account.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20A all as specfied and directed.
M&L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conduit concleaded including accessaries with4 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etcand connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length.
Even the smallest improvement in motor effeciency can significantly reduce energy consumption. EEF1 motors meant for countiniuos operation. These motor make the AHUs highly energy efficient. View port is provided on the fan door panel to enable monitoring the fan and motor status Marine lamp provides easy visibility door limit switch autoimatically trips the motor/ fan when the door is opened. The fan section is provided with an access door for ease of serviceability of the fan and motor user-friendly nylon handles can be operated from both inside and outside the casing complete all as specified and directed. Note : The cost of all equipments mentioned in the description such as fan, motor, slide rail, belt, flexible fire retardant canvas, coil, drain pan, various type of filter, control of damper, sand trap louvers, DIDW blowers, EEF1 motor, door unit switch, nylon handles, UPVC drain pipe line etc shall be include in the quoted rates. Nothing extra payable on this account.
Supply, intsllation, commissoing and testing of DX type AC system of capacity 11 TR. The AC system shall be air cooled type direct expansion type A.C. consists of a single phase drive axial flow fans, air cooled type condensing unit coil, hermetically/ semi -hermetically sealed R-22/ 710A refrigerant compresssor along with all compressor protection & safety devices. The accesories inmcludes all copper fitings i.e copper piping & 4 Core electrical wire as per requirment at site. Hard copper supply/ return liquid and gas line along with insulation, pipe support syastem, expansion devices, controls, for compressor safety out door unit support system along with condensate drainage system for air handling unit & also refnet joints / AHU Kits etc are includes in this job and complete all as specified and directed.
Supply, intsllation, commissoing and testing of fabrication of 24 gauge sheet metal works required and as specified at site.
Supply, intsllation, commissoing and testing of fabrication of 22 gauge sheet metal works required and as specified at site.
Supply, intsllation, commissoing and testing of fabrication of 22/ 24 gauge sheet metal works support system as required and as specified at site.
Supply, intsllation, commissoing and testing of air duct thermal insulation with site Glued, Aluminum foil faced XLPE cross linked insulation of suitable density, insulation of 13 mm Thick, class 'O' with one side factory laminated (For supply air duct insulation) and complete all as specified and directed.
Supply, intsllation, commissoing and testing of air duct thermal insulation with site Glued, Aluminum foil faced XLPE cross linked insulation of suitable density, insulation of 9 mm Thick, class 'O' with one side factory laminated (For return air duct insulation) and complete all as specified and directed.
Supply, intsllation, commissoing and testing of air & return Air Damper in extruded aluminium construction. Aluminium volume control dampers of opposed blades and in aerofoil design are provided to maintain the fresh-air to return air ration (For supply air/ return air/ fresh air)and complete all as specified and directed.
Supply, intsllation, commissoing and testing of suitable G.I. fire damper with fusible link. Complete all as specified and directed.
Supply, intsllation, commissoing and testing of therminal box is used to mount the HEPA Filter. The housing box shall be in aluminium & M. S. with all necessary fittings and easy maintenance. Boxes would be mounted to your false ceiling and connected to the supply air duct with flexible high quality canvas connector to give a vibration free installation. Guard shall be provided mechanical protection for the filters and will present a pleasing appearance in the room for following sizes.
Terminal HEPA boxes (450x450mm)
Terminal HEPA boxes (610x610mm)
Supply, intsllation, commissoing and testing of munipleat HEPA filters with multiple choice of design & dimensions, designed to remove particles down to 0.3 micron from air with effeciency exceeding 99.99%. The paper media used is folded over ribbons, glued strings and assembled into suitable casing. These filters contain much more medium for the same surface area of filter paper is compactly and safety assembled into a frame so that there is no leakage of unfiltered air passing through it for following sizes.
Minipleat HEPA filter (450x450x100mm)
Minipleat HEPA filter (610x610x100mm)
Supply, intsllation, commissoing and testing of PCGI return riser of size 610x80x2500mm, grills are manufactured by deft professionals utilising the most favourable PPGI & ultra modren technology. Provided gamut is made availble in ample range of specification and can be also well customized in other option as per site requirment and complete all as specified and directed.
Supply, intsllation, commissoing and testing of Magnahelic Gauges with M.S Powder Coated box with SS-304 top cover complete with necessary tubing to measures the diffrential pressure across the room -0-10 pa for classified area & 0-25 & 0-50mm for AHU and complete all as specified and directed.
Supply, intsllation, commissoing and testing of 6.0 KW electric heater with heater bank with all connected items/ parts/ cables etc to maintain RH 40% to 60%. Complete all as specified and directed.
Supply, installation, testing & commissioning of electric panel for AHU & AC system with RYB indicators , suitable capacity of SFU for isolation, contractors (star/ delta, DOL), Bimettalic relays, start/ stop push button, on/off/trip indicators for AHU motor & temperature indicators. Panel shall be totally enclosed with hinged doors, neoprene gasket and suitable for locking arrangement and complete all as specified and directed.
Supply, installation, testing & commissioning of air shower (01 person entry) with PRE FILTER:- Box Type PRE FILTER are made of Non-Woven Synthetic with HDPE mesh confirms to EU-06 grade, with an Efficiency rating better than 95% down to 5 micron. Motor Blower assembly:- Single phase motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of air low requirement for entire life. Pressure Gauge: - Magnehelic Gauge (0-100MM: 1 Nos.) to monitor pressure drop Lighting: Led Light (250 Lux) at work surface 40 Watt, ON/OFF Switches:- Key Pad ON/OFF Switches for motor & lights Control System: Interlocking system to ensure that both the doors cannot open at the same time & to ensure that both the doors stay locked during the time of air low. Time setting for Air shower:- Time setting for air shower operation time (Cycle for 30 seconds to 3 minutes) Emergency Operation:- Emergency stop will be provided Door Opening:- Straight entry straight exit and 90 degree door opening Operation Mode: Automatic As well as manual mode Door with door closer: -SS 304 doors with double flush glass view panels and door closer. Electric Supply: 230V AC1-050 HZ/415V AC 3-0 50 HZ, 3 Phase Supply, MOC-SS304, Noise Level: Less than 67 DB on scale 'A' when ambient is not greater than 55 DB on Scale 'A' Vibration Level :- Minimum Air Spray Nozzle& ACCESSORIES : SS 304 & SS HINGES & HANDLE MOC:SS304
S&F Aluminium extruded section body Door closer hydrau- lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F 250mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed
S&F 200mm Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete all as specified and directed
S&F Aluminium 4 lever Mortice lock, vertical type, size 100 mm complete all as specified and directed
S&F Butt hinges of size 100mm medium wt stainless steel ISI marked complete all as specified and directed
M&L sheet glass ordinary quality 5mm thick and glazing with aluminium flats in a square n exc 0.5 Sqm for aluminium door, windows and partitions complete all as specified and directed
M&L 4mm thick ACP sheet in partation/ceiling complete all as specified and directed. Note : Size and colour of the board will be decided at later stage as per ground requirement as directed.
NOTE APPLICABLE FOR ALL HVAC ITEMS :- All other items/ equipment's (minor/ major) required to maintain the temp i.e 23 degree celcius and relative humidity (RH) 40% to 60% shall be included in quoted rate and nothing extra will be paid on that account.
Abhishek Enterprises (BID ID -3450768)
M/S S. SINGH TRADERS (BID ID -3450927)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
8367TENDER.pdf
Tender Documents • 0.64 MB
BOQ_819055.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .