Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC HOUSE NO1201 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 410 501 | PALGHAR | MAHARASHTRA | 410501 | ₹14.6 L Quoted ₹15.4 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹16.9 L+₹1.5 L (9.72%)Rejected-Finance OFFICE 4 B JAY TENAMENT MADHUWAN PARK II BEHIND NIRMAL NAGAR RAMESHWAR NAGAR JAMNAGAR 361006 | JAMNAGAR | GUJARAT | 361006 | ₹16.9 L+₹1.5 L (9.72%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹18.1 L+₹2.6 L (17.0%)Rejected-Finance HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | ₹18.1 L+₹2.6 L (17.0%) | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹19.4 L+₹3.9 L (25.6%)Rejected-Finance | ₹19.4 L+₹3.9 L (25.6%) | L4 | Rejected-Finance Not lowest bidder |
| 5 | Rejected-Technical GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | - | - | Rejected-Technical NOT RECOMMENDED NOT ENLISTED IN CATEGORY b(ii) |
| Sl No | Description | Qty | Unit | M/s. AMIT ASSOCIATES L1 | JAMDAGNI ENGG WORKS L4 | NILESH SUBHASH KARALE L3 | NAVIN K LAKHANI L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for maintenance & servicing of VCB / RMU11 KV, 400/ 630 /1200 Amps including removal of VCB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, servicing of relays, etc. refixing the VCB trolley to its original position including proper setting of manual/ motorize operation of VCB, checking/ setting of tripping system, etc complete. Note:- (i) Servicing & Maintenance shall be carried out by the Authorized person of manufacturer. (ii) After completion, test certificate shall be furnished. (iii) Quoted rates are also deemed to include for calibration of relay by injecting High voltage through CTS, checking the over load system of VCB upto 90 % rated load and artificial fault creation and setting of relay by 10 to 15 % of rated load, removing u/s overload and earth fault relay including connection with power pack and opening out the trolly, checking the operation of VCB mechanically and electrically through shunt trip coil including energizing of springs automatically including checking of TNC switch complete as directed. | 8 | Each Job | 14,000 ₹1,12,000 Lowest | 31,111 ₹2,48,888 | 15,000 ₹1,20,000 | 14,200 ₹1,13,600 |
| 2.00 | M & L for taking down carefully Transformer / Isolation transformer/SVR of 100 KVA to 500 KVA and above capacity, any make, any type from pole / plinth/ base; disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm; shifting / transporting transformer carefully from the site to the workshop; opening the top cover of the transformer, bushing, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs/replacement of worn out part; ovening the complete unit till to get desired megger value, transporting, returning back to the site, installing, re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by EIC. Note : Spares, Rewinding of transformer,reinsulating & heating if required will be measured and paid separately under respective BoQ items. | 1 | Each | 16,000 ₹16,000 | 21,111 ₹21,111 | 16,400 ₹16,400 | 15,800 ₹15,800 Lowest |
| 3.00 | Supply & Fix in repair of Top cover gasket made up of 5 mm thick cork sheet. | 1 | JOB | 800 ₹800 | 3,111 ₹3,111 | 500 ₹500 Lowest | 1,000 ₹1,000 |
| 4.00 | Supply & Fix in repair of HT bushing, porcelain vitreous brown body 11 KV grade as per IS 3347. | 3 | Each | 600 ₹1,800 Lowest | 5,111 ₹15,333 | 650 ₹1,950 | 600 ₹1,800 Lowest |
| 5.00 | Supply & Fix in repair of LT bushing, porcelain vitreous brown body 1100 V grade as per IS 3347. | 4 | Each | 580 ₹2,320 | 5,111 ₹20,444 | 558 ₹2,232 | 550 ₹2,200 Lowest |
| 6.00 | Supply & Fix in repair of HT brass studs along with washers for one terminal 11 KV transformer. | 3 | Each | 700 ₹2,100 | 5,111 ₹15,333 | 680 ₹2,040 | 670 ₹2,010 Lowest |
| 7.00 | Supply & Fix in repair of LT brass studs along with washers for one terminal 1100 Volts grade transformers. | 4 | Each | 650 ₹2,600 Lowest | 5,111 ₹20,444 | 730 ₹2,920 | 720 ₹2,880 |
| 8.00 | Supply & Fix in repair of Breather assembly complete with silica GEL of make Omkar/Kamal/ equivalent as approved by GE. | 2 | Each | 900 ₹1,800 Lowest | 2,111 ₹4,222 | 1,020 ₹2,040 | 1,000 ₹2,000 |
| 9.00 | Supply & Fix in repair of Temp level indicator including its bolts, nuts, gasket etc complete. | 2 | Each | 800 ₹1,600 Lowest | 3,111 ₹6,222 | 1,060 ₹2,120 | 1,050 ₹2,100 |
| 10.00 | M & L in repair of Rewinding old / burnt out HT/LT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, varnishing, heating, keeping coils in position, etc for transformer up to 500 KVA. | 120 | Kilogram | 1,200 ₹1,44,000 Lowest | 2,111 ₹2,53,320 | 1,300 ₹1,56,000 | 1,295 ₹1,55,400 |
Tender Value
₹14.9 L
EMD Value
₹30,000
Closing Date
26 Jun 2026, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
REPAIR/REPLACEMENT OF INSULATORS/HT VCB/RMU PANELS/MAINTENANCE OF TRANSFORMER AND TWO POLE STRUCTURE AND EARTH PITS AND ALLIED WORKS AT AF STN MOTHALA UNDER GE (AF) NALIYA
2026_MES_769491_1
85334/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NALIYA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) NALIYA
₹30,000
Yes
24 Jul 2026
3 Jun 2026
29 Jun 2026
3 Jun 2026
26 Jun 2026
18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for maintenance & servicing of VCB / RMU11 KV, 400/ 630 /1200 Amps including removal of VCB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, servicing of relays, etc. refixing the VCB trolley to its original position including proper setting of manual/ motorize operation of VCB, checking/ setting of tripping system, etc complete. Note:- (i) Servicing & Maintenance shall be carried out by the Authorized person of manufacturer. (ii) After completion, test certificate shall be furnished. (iii) Quoted rates are also deemed to include for calibration of relay by injecting High voltage through CTS, checking the over load system of VCB upto 90 % rated load and artificial fault creation and setting of relay by 10 to 15 % of rated load, removing u/s overload and earth fault relay including connection with power pack and opening out the trolly, checking the operation of VCB mechanically and electrically through shunt trip coil including energizing of springs automatically including checking of TNC switch complete as directed. | 8 | Each Job | 1 | ₹8 |
| 2 | M & L for taking down carefully Transformer / Isolation transformer/SVR of 100 KVA to 500 KVA and above capacity, any make, any type from pole / plinth/ base; disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm; shifting / transporting transformer carefully from the site to the workshop; opening the top cover of the transformer, bushing, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs/replacement of worn out part; ovening the complete unit till to get desired megger value, transporting, returning back to the site, installing, re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by EIC. Note : Spares, Rewinding of transformer,reinsulating & heating if required will be measured and paid separately under respective BoQ items. | 1 | Each | 1 | ₹1 |
| 3 | Supply & Fix in repair of Top cover gasket made up of 5 mm thick cork sheet. | 1 | JOB | 1 | ₹1 |
| 4 | Supply & Fix in repair of HT bushing, porcelain vitreous brown body 11 KV grade as per IS 3347. | 3 | Each | 1 | ₹3 |
| 5 | Supply & Fix in repair of LT bushing, porcelain vitreous brown body 1100 V grade as per IS 3347. | 4 | Each | 1 | ₹4 |
| 6 | Supply & Fix in repair of HT brass studs along with washers for one terminal 11 KV transformer. | 3 | Each | 1 | ₹3 |
| 7 | Supply & Fix in repair of LT brass studs along with washers for one terminal 1100 Volts grade transformers. | 4 | Each | 1 | ₹4 |
| 8 | Supply & Fix in repair of Breather assembly complete with silica GEL of make Omkar/Kamal/ equivalent as approved by GE. | 2 | Each | 1 | ₹2 |
| 9 | Supply & Fix in repair of Temp level indicator including its bolts, nuts, gasket etc complete. | 2 | Each | 1 | ₹2 |
| 10 | M & L in repair of Rewinding old / burnt out HT/LT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, varnishing, heating, keeping coils in position, etc for transformer up to 500 KVA. | 120 | Kilogram | 1 | ₹120 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
85334TENDER.pdf
Tender Documents • 11.43 MB
4.EM SEPERATE.pdf
Tender Documents • 9.55 MB
BOQ_861732.xls
BOQ • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .