Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹72.6 LAccepted-AOC AT NIMIDHI PARADEEPGARH JAGATSINGHAPUR 754141 | PARADEEPGARH | JAGATSINGHAPUR | ODISHA | 754141 | ₹72.6 L | 1 | Accepted-AOC Ist Lowest bidder |
| 2 | 2₹73.3 LRejected-Finance | ₹73.3 L | 2 | Rejected-Finance 2nd Lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Below Weightage |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Below Weightage |
Updated dates
Tender Value
₹72.6 L
EMD Value
₹72,571
Closing Date
23 Dec 2025, 5:00 pmClosed
General Manager, WATCO Division, Puri
General Manager, WATCO Division, Puri, Odisha, Phone-06752-223447
Supply installation testing and commissioning of On-Grid ground mounted 130KW solar power plants at STP Mangalaghat Puri
2025_WPURI_122377_1
GMWATCOPURI/19/2025-26
National Competitive Bid
Electrical Works
90 days
Puri
Please refer to the tender Documents
3 documents required · 3 mandatory
₹11,800
₹72,571
Yes
9 Mar 2026
8 Dec 2025
24 Dec 2025
8 Dec 2025
23 Dec 2025
8 Dec 2025
8 Dec 2025 - 12 Dec 2025
Supply, fitting, fixing of G.I structure frame using hot-dip galvanized iron (GI) for components like rails, legs, and purlins, typically with an 80-micron zinc coating, as well as Stainless Steel (SS) 304 for module fasteners over of channel poste of (100x50x6mm. Thk) 23 poles including cost of materials, transportation to site,all labour,T & P etc alll complete.
Supply, fitting, fixing of Solar Panel Mounting 41x 41 x 2mm GI Structure designed specifically for 8 panels with a power range of 550-600W. This sturdy and durable structure is made from high-quality galvanized iron. It will support 600W and above 4Panels consisting of 4 Purlin for extra protection from heavy wind. 4 Purlins will prevent panels from cracks. The mounting structure is designed to securely hold and position the solar panels, maximizing their exposure to sunlight for optimal energy generation & Its adjustable design allows for easy installation and customization according to your specific requirements with its robust construction and compatibility with a wide range of solar panels, our Solar Panel Mounting GI Structure offers a reliable and efficient solution for your solar power system. Invest in this reliable mounting structure to enhance the performance and longevity of your solar panels Hot Dip G.I End clamp & middle Clamp, SS Alen bolt. 10mm Fastners and heavy plain washers (comprising of set U Channels 40x40x40x2 mm Front Leg U Channel 29 Inch 4 No. Back Leg U Channel 45 Inch 4 No. Purlin (Support) 97 Inch 3 No.Rafter 58 Inch 2 No. Base Plate 4 No.Hot Dip Z (End) Clamp 35mm 6 No. Hot Dip U (Mid) Clamp 35mm 3 No. G.I. Degree Hanger 4 No. G.I. Spring Nut 9 No. SS Allen Bolt 40mm 9 No. G.I. Nut and Bolt 10x25 mm 24 No. G.I. Nut and Bolt 10x60 mm 6 No. G.I. Plain Washer 82 No. Fasteners 10mm 16 No. Approx. Weight 38 KG. over G.I slotted channel frame made out of channel (100x50x6mm. Thk) including cost of materials, transportation to site,all labour,T & P etc alll complete.
Supply, fitting & fixing of Photo voltic shell having 550W-600W with half cut Mono PERC Solar Module 218nos over GI structure. including cost of materials, transportation to site,all labour,T & P etc alll complete 600 watt Solar PV
Supply, fitting, fixing of three Phase String On Grid with Hybrid technology(MPPT) Solar Inverter Solar inverter of ABB/DEY make suitable to generate 120KW powerfor solar power station 2 set.including cost of materials, transportation to site,all labour,T & P etc alll complete. ( 1W+1S)
Supply, fitting, fixing of Lighting arrestor with earthing pit over solar Pv structure area .including cost of materials, transportation to site,all labour,T & P etc alll complete
Supply, fitting & fixing of DC copper cable of 6 sqmm with PVC pipe including cost of materials, transportation to site,all labour,T & P etc alll complete.
Supply, fitting & fixing of DC copper cable of 10 sqmm with suitable dia PVC pipe including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting & fixing of armored copper cable from inverter to MCC panel of size 95 sqmm with necessary cable tray including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting & fixing of net meter with copper cable from inverter to MCC pannel of required size including cost of materials, transportation to site,all labour,T & P etc alll complete
Supply fitting fixing of copper socket 10sqmm (370x2) including cost of materials, transportation to site,all labour,T & P etc alll complete
Supply fitting fixing of PVC Juction box with copper terminals including cost of materials, transportation to site,all labour,T & P etc alll complete
Supply installation, testing & commissioning of PLC in door panel with Panel Air Conditioner Made out of 2MM C.R sheet of size (800m*800mm*2100mm floor mounted) powered coated 7 tank process with following component i.e, CPU should have 1MB Program memory with extended memory slut, Redundand-24VDC, SMPS 10 AMP along with 24 v edc spd, io count as DI-20,DO-20,AI-20,AO-20 & MOSBYS-10. sUBSYSTEM SHALL BE SAME SERIES AS cpu,12 iNCH panel Mounted HMI, Modem should have support MQTT Protocol by default, 24 volt DC Industrial Switch with miniim 6 earthmate, 4SFP Port each AI shall be equiped with suitable signal isolator of 2 Nos & surge protection device 20 nos LIU I solator, 230 Volt AC/23 volt Ac torroidal transfemer, 1kVA 230V AC UPS should have capacity to charge 3 nos 12VDC 65 AH bATTERY bANK, DP MCB of Adequate current capacity, Led tube light 10 inch 5 watt door limit switch louver, 4 sqmm straighi through terminal & fuse terminal 90 nos, earthing plate. The Approved Make:L (PLC -Sieemens, Phonix, ABB, Mistubishi, SMPS-Phoneix, Slemens, Schnider Isolater-Masibus, R5ishabh, Multispan, SPD-Phones, Mersen, Dehm, UPS-Vertive, Hitachi, High Ril, Avo, Earthmate switch - Siemense, Moxa, Phoneis) Including cost material with all taxes transportation to site/storage with insurance
Supply, Installation, testing and commissioning of RACK Mounted Data logger with SSD 1TB storage including cost of labour, T&P etc all complete
Supply, Installation, testing and commissioning of RACK Mounted 3G, 4G and 5G modem for remote data communication including cost of labour, T&P etc all complete.
Supply, Installation, testing and commissioning of Post Paid Data SIM with Static IP along with 5GB/month data annualy subscription for remote data VPN communication modem including cost of labour, T&P etc all complete
Supply, installation & commissioning of SCADA software(Schneider/Siemens/Phoenix Contact) with graphical processor, visualization, Advanced alarm management, historical and real time trending, Built-in report in, Statistical process control, Multi threaded VBA programming language with 128 KB tag capacity, IKVA online 'UPS with 30Min battery backup-1Nos, CPU having preloaded with win-10, 15 latest gen processor; DDR4 8gb RAM, 500gb SSD (Make- HP/Dell/Lenovo), USB based keyboard-1 no, USB based Optical Mouse- 1no, 43" LED monitor- 1 No, A4 size Laser printer- 1No, Wooden computer table- 1 no, Preparation of P&I diagram, creation of multi visualisation screen for process control, alarm management, Historical & real time process trend, daily reporting etc complete as per requirement & 'direction of engineer - in - charge
Supplying all materials Laying ,labour, T&P, for laying of cable tray specification (Male-polycab/Lapp/Thermo) including cost of materials, transportation to site,all labour,T & P etc all complete. 1.5 SQMM 6 crore armored cable
Supply, fitting & fixing of three phase multy function eletronic energy meter wih necessary wireing for 6 set of sewerage pump set of ABB/Sequare make including cost of materials, transportation to site,all labour,T & P etc all complete.
Supply, fitting & fixing of 2 core screened cable ( Make LAP) from out let effuent channel to Control room for data transmission with necessary conduct pipe including cost of materials, transportation to site,all labour,T & P etc alll complete
Supply, fitting & fixing of 6 core screened cable ( Make LAP) from pump house to Control room for data transmission with necessary conduct pipe including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting & fixing of 12 core screened cable ( Make LAP) from pump house to Control room for data transmission with necessary conduct pipe including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting & fixing of 24 core screened cable ( Make LAP) from pump house to Control room for data transmission with necessary conduct pipe including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, installation of chemical earthing with crystalline conducting materials for Back FILL COMPOUND & INSTALLATION OF Maintenance Free Earthing Electrocode with ISI mark G.I. Pipe dia 50mm as Secondary electrode with wall thickness of 2.6mm and the primary earthing electrode will be 25mm*6mm hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the primary earthing & the secondary earthing. A solid G.I. Base plate of 300*30 mm seals the unit at the bottom. Ground filling compound will be provided in 25kg per bag-2nos. Excavation of earth pit refilling, Precast RCC chamber with lid etc. All complete as per the site requirement.
Supply, installation & commissioning of 200 Amp,415 VAC three phase contacter with protection latch & necessary wireing in the existing pannel including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, installation & commissioning of net metering with necessary wireing including cost of materials, transportation to site,all labour,T & P etc all complete.
SPV formation, processing fee and other permission approvals from TPCODL. Transportation of all equipments & its testing at site, procurement of skilled & unskilled manpower, travel expenses, lodging and boarding of engineers, etc all complete
RCC Foundations for GI post pillars with necessary excavation ,Shuttering,reinforcement,cement conconcrete of M-20 to the designed depth with 50MT/ bars, construction of foundation for PV structure contour (Area grading and clearing of jungle) and laying of water pipelines for cleaning including cost of materials, transportation to site,all labour,T & P etc all complete.
Errection & commissioning of PV solar pannels,GI structure ,Inverter including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting , fixing & commissioning of water pipe line ,necessary nozle for each pannel with pressure pump & control valve for each row,strainer with eletricla wering including cost of materials, transportation to site,all labour,T & P etc all complete
Furnishing of control room, installation of server,Solar pannel inverter AC control desk necessary eletrical weiring including cost of materials, transportation to site,all labour,T & P etc all complete
Supply, fitting , fixing & commissioning of 2000 ltr PVC water tank ,for automatic cleaning PV pannel with necessary pipeing including cost of materials, transportation to site,all labour,T & P etc all complete.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_568663.xls
BOQ • 0.34 MB
DTCN.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid