| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹1.0 Cr+₹2.5 L (2.50%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹1.1 Cr+₹13.4 L (13.5%)Rejected-Finance RAMBHAWAN MOUNT ABU SADAR BAZAR MOUNT ABU PIN 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹1.1 Cr+₹14.6 L (14.8%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹1.1 Cr+₹15.8 L (16.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
18 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE Jodhpur Zone Jodhpur
HQ CE Jodhpur Zone Jodhpur
MODERNISATION/ UPGRADATION OF CENTRAL ENGG SERVICES AT BHUJ MIL STATION (JOB NO 006/AMWP/12C/2019-20)
2020_MES_352626_1
800504/BHUJ/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Bhuj
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE Army Bhuj
₹2.6 L
Yes
7 Aug 2020
13 Jun 2020
20 Jul 2020
13 Jun 2020
18 Jul 2020
4 Jul 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for foundation of pole/stay/cable etc and getting in soft/loose soil complete all as specified and as directed by Engr-in-charge
All as per item No 1 here-in-before but depth exceeding 1.5 m & not exceeding 3 m all as specified and directed
Returning refiling including spreading, leveling, watering and well raming in layers each not exceeding 25 cm thickness complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
M&L for dry sand cushioning to under ground cable intrenches including spreading,levelling, ramming,watering and consolidation complete all as specified and directed. Note : Punnend thickness of sand layer shall be measured and paid to contractor.
Supply and laying un-reinforced precast concrete cable cover, class HVP, Type1 with peak size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for PCC type D-2 (1:4:8) using 40mm graded stone aggregates in foundation and bed plates of electric poles, struts etc incl neccessary form work and fair finish to exposed surface without using extra cement etc. complete all as specified and directed.
M&L for PCC type C-1 (1:3:6) using 20mm graded stone aggregates in foundation and bed plates of electric poles, struts etc incl neccessary form work and fair finish to exposed surface without using extra cement etc. complete all as specified and directed.
M&L for PCC type B-1 (1:2:4) using 20mm graded stone aggregates as in bands, coping etc. including slightly rounded or chamfered angles complete as specified and directed.
Supply laying & testing cable (earthed) XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 11000 volts grade, of size 3 core 185 Sq MM.
Supply and fix cable end termination kit for 11 KV grade cable for outdoor type heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 185 Sq mm
M&L for cable jointing kit 11 KV (Earthed) grade cable for straight heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 185 Sqmm
M & L for lightning arrestor expulsion type, distribution class with all fittings, discharge capacity 65 KA, current rating 10KA, suitable for 11000 volts, complete connecting with ACSR jumper from LA to Air Break Switch with PVC sleeve complete all as specified and directed by Engineer in Charge
M & L HT 11 KV TP outdoor type gang operated device suitable for horizontal/vertical type mounting on insulator and steel frame with GI operating rod of suitable length and size and rating upto 200 Amps 11000 Volts 3 Phase alongwith locking arrangement, MS clamps, bolts, nuts and washers etc including two coats of aluminium paint over a coat of redoxide primer on MS work complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm, burried vertically in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5m below ground level, connected to galvanised steel earth lead wire 4.00 mm dia (8 SWG) of any length as reqd at site, by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 15mm bore G.I. light grade pipe for protection of GI wires 20 mm dia watering pipe medium grade including charcoaldust and common salt packed all around the earth plate, including necessary excavation and earth work in any typeof soil/strata and testing complete all as specified and directed and shown on electrical plate No. 5 of SSR Part I (1991) Note:-GI strip/Wire more than 7.5 m will be measured separately.
All as per item No 17 here-in-before but using galvanised iron strip 32 x 6mm as earthing lead
Supply and fix HT cable route indicator duly painted with grey colour synthetic enamel paint two coats over one coat of red oxide primer, oval shape of size 200mmx150mmx6mm thick cast iron disc with letters embossed and fixed on 25mmx25mmx5mm thick MS angle iron for 50mm long including necessary PCC in 1:3:6 type C1 cement concrete 20mm aggregate and 15mm thick plastering all around below ground level of size 650mmx300mmx250mm embedded in PCC block all as specified
M & L Pre-stressed concrete pole, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specified and directed. Note:- Excavation, earthwork and foundation concrete shall be measured and paid separately under respective items.
Supply and Fix energy efficient Integrated Solar LED Standalone Street Light 24 Watt 92 days backup) in Single body Solar PV Panel 100 Wp Low maintenance Lead Acid Tubular Battery 12 V, 60 AH , 2400 Lumen, with adjustable MS clamp suitable for pole/wall mounting of height 5 meter above ground with base plate complete.
Boring of holes under road, pavement hard standing by trenchless technology using ultra sounding technique and necessary machine incl HDPE pipe 150 mm dia suitable for 0.4 mpa working pressure
S&F Danger notice plate of 1.6mm thick mild steel sheet,vitreous enamelled white,with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size,for HT 25X20 cm size
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white brown or green, single disc assembly all as specified and as directed.
S&F Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia suitable for 11000 volts grade all as specified and as directed.
M&L for Cross arms, bracings supports clamps and back plates fabricated fro structural steel sections including nuts, bolts and washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and directed
M&L for Aluminium conductor,steel reinforced for overhead lines complete all as specified and directed.
M & L for aluminium lugs of size 35 Sqmm suitable for overhead conductor/end termination kit to GOD (11 KV) complete all as specified and directed by Engineer in Charge.
M&L for 100 mm (4") dia galvanised pipe light grade for cable protection complete all as specified and directed
S&F Anti climbing device spikes type fabricated out of M.S bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole
Dismantling of Concrete poles/struts of any size and capacity
Dismantling cross arms of MS Channels or angle sections etc complete and setting aside
Dismantling of earthwire guard wire etc complete
Dismantling insulators of any type capacity and size
Dismantling stay assembly complete.
Dismantling ACSR Conductor or AAC Conductor
Anil Builders
M/s Matadeen Ramchandra Agarwal
M/s SK Traders
JAMNAGAR ELECTRIC AND MACHINERY CO
KB PROJECTS
MUKUL ENGINEERING
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .