Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.7 L+₹24,550 (5.46%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹5.6 L+₹1.1 L (24.5%)Rejected-AOC B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical LANE NO 03 PRAGATI VIHAR RISHIKESH | - | Not Admitted-Fee/PreQual/Technical Others-Tender withdrwal by the bidder | |
| 5 | Rejected-Technical 247 DHAMPURA LAKSAR ROAD DISTT HARIDWAR 249408 UTTARAKHAND | HARIDWAR | HARIDWAR | UTTARAKHAND | 249408 | - | Rejected-Technical NOT MEET TQR |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
1 Mar 2023, 1:00 pmClosed
S E (O and M) Circle,Roorkee
Superintending Engineer (O and M) Circle, PTCUL, 26 Civil Lines, Roorkee
Routine Maintenance/overhauling of 132/33 KV equipment at 132 KV Substation Laksar
2023_PTCUX_54427_1
T-31SEO and MCR/2022-23
Open Tender
Miscellaneous Services
Item Rate
60 days
Laksar Haridwar
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
S E (O and M) Circle,Roorkee
₹18,000
Yes
7 Sept 2023
31 Jan 2023
2 Mar 2023
31 Jan 2023
1 Mar 2023
31 Jan 2023
Amount
Work of preventive maintenance of 40MVA T/F including cleaning/washing of complete transformer,tightening of clamp and connector, neutral and main body earthing.
Work of repairing & overhauling of 33KV Circuit breaker through Authorised Service Engineer of manfacture of Circuit breaker
i) Work of proper cleaning, lubrication & greasing of operating mechanism, spring charge mechanism. ii) Proper Cleaning of porcelain insulator. iii) checking of SF-6 Gas pressure and rectifying leakage of SF6 Gas & refilling of SF-6 Gas upto desired pressure wherever required. iv) Checking & tightening of all electrical connections & cleaning of terminal connecetions. v) Replacement of damaged tripping/ closing coils wherver required.
Work of complete testing of 33KV Circuit breaker such as i) Measurement of Contact Resistance, closing & tripping Time,CRM,IR Values etc. ii) Checking proper remote & local/ manual operation for smooth operation of breakers.
Work of tightening of conductors/jumpers of different bays and Buses. Work includes ensuring tightening of clamps, conductors, jumpers blades at different equipments like on Isolators, CBs, CT/PTs,Transformer with proper torque etc. in the bay for BUS by opening maintaining and re-tightening the same and if required rusted nuts & bolts shall be replaced.
132 KV Bay
132KV Bus
33KV Bay
33KV Bus
Work of cleaning of porcelain insulators of different type of 132/33 KV equipmens like CBs,CT/PT,Disc Insulator and Isolator and transformers.
Work of overhauling/repairing of Isolators/earth switch mechanism of bay by oiling/greasing/proper alignment of moving part of mechanism.
132KV Bay
33KV Bay
Work of tightening of conductors/jumpers,connectors and associate jumpers/conductors of 33KV Jack Bus. Work also includes replacement of clamp/connector and cleaning of porcelain portion of Isolators.
Work of replacement of burnt and damaged jumpers of 33KV Bays complete in all respect.
Work of replacement of burnt and damaged jumpers of 132 KV Bays complete in all respect.
Work of proper cleaning of the rust and loose paint by rubbing with iron brush and emery paper and wiping it with cotton cloth for making the surface smooth. After proper cleaning applying one coat of Red oxide (primer) and two coat of first quality green color synthetic enamel paint both side of the fencing.
Work of dismantling & fixing of 3 phase AC transformer cooling fan of 40MVA T/F.work also includes complete overhauling of transformer cooling fan work which includes cleaning of fixed and moving parts, replacement of damaged bearing, oiling, greasing and re-assembling of fan.
Providing & Fixing of 100Amp capacity 3 Pole MCCB make of Anchor,Phillips, C&S,L&T in ACDB
Providing & Fixing of 63 Amp capacity 4 Pole MCCB make of Anchor,Phillips, C&S ,L&T in ACDB
Providing & Fixing of 125Amp capacity 4 Pole MCCB make of Anchor,Phillips, C&S ,L&T in Marshaling Box
M/S AMIT ASSOCIATES
M/s Singhal and Co
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .