Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹25.8 L+₹2.4 L (10.3%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹26.1 L+₹2.7 L (11.7%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹57,420
Closing Date
20 Mar 2021, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
SPECIAL REPAIRS OF ROOFING AND BIRD PROOFING OF STATION WORKSHOP AND BLDG NO P89 AT AF STN SURYALANKA
2021_MES_424012_1
CWE(AF)/TVM/SUR/82329
Open Tender
Civil Works
Item Rate
180 days
Suryalanka
As per NIT
7 documents required · 7 mandatory
₹500
AGE I AF Suryalanka
₹57,420
Yes
23 Apr 2021
20 Feb 2021
22 Mar 2021
20 Feb 2021
20 Mar 2021
6 Mar 2021
20 Feb 2021 - 2 Mar 2021
Amount
SCHEDULE 'A'
Taking down cement or cement lime plaster, any description, on brick walls including racking out joints hacking for key scrubbing down with water etc. all as specified and directed.
Demolition of Brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth with out using extra cement all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in two layers, first layer 10 mm thick in CM 1:6 and second layer 5 mm thick in CM 1:4 finishing fair and even mixed with WPC as per manufacturer's instructions all as specified and directed. (Note : Supply of water proofing compound shall be measured and paid seperately).
Supply only of integral water proofing compound of approved make all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, below or above ground level all as specified and directed.
M&L for Brickwork with sub-class `B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 all as specified and directed.
Dismantling of asbestos cement (corrugated/semi corrugated, etc.) sheets & ridge in roof coverings all as specified and directed.
Supply and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws etc fixed with L- or J- type or cranked hook bolts alongwith bituminous washers, in lieu of screws complete all as specified, directed and as per manufacturer's instructions.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of Fe 550 Mpa as in roof ridge fixed with self tapping screws as specified.
M&L 100mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate as in sub base complete all as specified and as directed.
M&L for machine cut kota stone slab 20-25 mm thick in flooring over and including 15 mm thick cement screed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed all as specified and directed.
M & L Rolled mild steel sections conforming to Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as spd and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash all as specified and directed.
S&F welded steel wire fabric n. exc. 4 kg per sqm, fixed complete to wood or steel members s all as specified and directed.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in framed work as in doors or gates of angle or other section with gusset plates, rails braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening including hold fast and fixing complete all as specified and directed by Engineer-in-charge.
M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), and aprons removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L for joint free non Skid ceramic coloured tiles (matte finish) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15 mm thick screed in cement mortar 1:6 all as specified and directed.
M&L for 100 mm high skirting with joint free non Skid ceramic coloured tiles (matte finish) 7 to 8 mm thick high area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 10 mm thick plaster in cement mortar 1:4 all as specified and directed.
Taking down chowkats or frames (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 Sqm each including making good disturbed portions with PCC 1:2:4 type B-0 or in cement mortar 1:4 after removal of frames all as specified and directed.
S&F for Pressed steel frames 105 x 60mm size for doors with one rebate including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-0 using 12.5 mm graded stone aggregate for filling of hollow portions of door frames etc., all as specified and directed.
S&F for 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), and aprons removing serviceable tiles to store and rubbish off the premises all as specified and directed.
Taking down chowkats or frames (without taking off shutters from the frame) not exceeding 1.5 Sqm each including making good disturbed portions with PCC 1:2:4 type B-0 or in cement mortar 1:4 after removal of frames all as specified and directed.
Demolition of cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed.
Taking up or down 15mm dia steel tubing and connections including cleaning for refixing or removing from site all as specified and directed.
Taking up or down 20mm dia steel tubing and connections including cleaning for refixing or removing from site all as specified and directed.
Disconnecting existing tanks, exc. 500 ltrs and n.exc. 1000 ltrs capacity, setting aside (or lowering if required) for repairs of roofs and hoisting if required, reconnecting and refixing in position all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes, 150 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes, 100 mm internal dia (Salt glazed stoneware, AC or reinforced concrete) set in cement mortar all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in screed bed below floor tiles etc. all as specified and directed.
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed in cement mortar 1:6 all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/300 x 200 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inlcuding 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for 18-20 mm thick Granite stone slabs of any type machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over and including 15 mm thick screed in cement mortar 1:6 all as specified and directed.
M&L for granite stone tiles 18- 20 mm thick machine cut in skirting/dado over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete.
S&F for Pressed steel frames 125 x 60mm size for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F for 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F for 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc. (with out sash bars), edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass, wire gauge etc. ; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats all as specified and directed.
M&L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed by Engineer-in-charge.
S&F of powder coated anodised aluminium window and ventilator glazed shutters, side hung type without sash bars aluminium sections weighing 0.55 kg/m (standard aluminium section of DG-2496 of sizes 39.4 x 17.7 mm and 1.2 mm thick (min) including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2Nos), suitable handle (1Nos) for each shutter complete all as specified and directed by Engr-in-charge.
S&F anodized aluminium window and ventilator fly proof shutters, without sash bars, with standard aluminium fly mesh sections of size 43.0x14.0mm and 1.2mm (min) thick including necessary rubber beads for fixing, joining cleats, screws as per manufacturers instructions all as specified and directed.
S & F of Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden/aluminium beeds all as specified and directed.
S&F of 4 mm thick Sheet Glass, ordinary quality and glazing with aluminium beads all as specified and directed.
S&F of 4 mm thick Figured glass, pin head type and glazing with aluminium beads all as specified and directed.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F 150 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F of 100 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F of 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F of 100 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 75 mm long Aluminium butt hinges extruded aluminium alloy with galvanised steel wire pin anodised, type C-22 all as specified and directed.
S&F of 300 mm long aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F of Mild steel 300 mm ,ordinary rat & tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F of curtain rods (drapery rods) not less than 25 mm dia, anodised aluminium alloy with fixing brackets fixed in repairs all as specified and directed.
S&F of factory made PVC Solid Door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube, fixed in opening as all as specified and directed.
S&F of Factory made Solid panel PVC Door Shutter of 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colourr PVC 'C' channel having a PVC sheet strip 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain clour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beeding and jointed together with solvent cement all as specified and directed.
S&F floor door stopper, with 140 mm long of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor all as specified and directed.
S&F in repairs,aluminium extruded section door closer hydraulically regulated, designation No.2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 61 to 80 Kg and fixed all as specified and directed by Engrineer-in-Charge.
M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 on wall finishing even and smooth with out using extra cement all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:3 in ceiling finishing even and smooth with out using extra cement all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in two layers, first layer 10 mm thick in CM 1:6 and second layer 5 mm thick in CM 1:4 finishing fair and even mixed with WPC as per manufacturer's instructions all as specified and directed. (Note : Supply of water proofing compound shall be measured and paid seperately).
Supply only of integral water proofing compound of approved make all as specified and directed.
M&L for Brickwork with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6, type C-1, using 20mm graded stone aggregate as in plinth protection, paving etc. with surfaces finished even and smooth without using extra cement all as specified and directed.
S&F of 20 mm outer dia 3 layer PP-R poly-propylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., including taking up or down steel tubing and connections all as specified and directed.
S&F of 25 mm outer dia 3 layer PP-R poly-propylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., including taking up or down steel tubing and connections all as specified and directed.
S&F rotational moulded polyethylene water storage tanks IS : 12701 - 1996 marked (cylindrical vertical with closed top) of 500 Ltrs capacity with and including 20mm dia Ball brass valve high pressure with polythene float and fly nut screwed for iron pipe or brass and fixed etc complete all as specified and as directed.
S&F for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., fixed in repairs complete including making good to floor all as specified and directed by Engrineer-in-Charge.
S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, (excluding flushing cistern) with and including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, all as specified and directed by Engrineer-in-Charge.
S&F in repairs vitreous china urinal, stall type, white complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement,fixing automatic flushing cistern with brackets, flush pipe, grating and union for complete all as specified and directed by Engrineer-in-Charge.
S&F of 10 lit capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repairs, all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China wash basin, white, flat back, of size 550x400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets and brass, 32 mm dia chromium plated waste fitting and 40 mm bore PVC waste pipe all as specified and directed by Engineer-in-Charge.
S&F of CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, all as specified and directed.
S&F in repairs of 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
S&F in repairs of Stop valves 15 mm bore, cast copper alloy screwed down high pressure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions, all as specified and directed.
S&F in repairs 15 mm bore Bib taps, chromium plated, cast copper alloy, screwed down, screwed for iron pipe, all as specified and directed.
S&F of PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and directed.
S&F of Towel rail 600 mm long of PTMT minimum weight 190 gms, fixed with and including chromium plated brass screws and wooden / plastic cleats all as specified and directed..
S&F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls or laid in floors as in soil, waste and pipes including dismantling of old pipes all as specified.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door, fixed in repairs all as specified.
S&F of 110 mm bore PVC (SWR) junction, single (Single T) equal or unequal provided with access door, fixed in repairs all as specified.
S&F of 110 mm bore PVC (SWR) Vent cowl fixed in repairs all as specified.
S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls or laid in floors as in soil, waste and pipes including dismantling of old pipes all as specified.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door, fixed in repairs all as specified.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement , fixed in repairs all as specified.
M&L for Preparing new or previously un treated surfases of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer including removal of old existing surface of wall all as specified and directed.
M&L for preparing old painted surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash all as specified and directed.
M&L for preparation of old plastered surfaces of ceilings and applying two coats of white wash all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of white wash all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
M&L for preparation of old painted surfaces of walls and applying one coat of oil bound distemper all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bulbs etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixedin and including Concealed PVC conduit, fitting and accessories, junction boxes including one 1.5 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, making good, for One light point controlled by one switch complete all as specified and directed
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixedin and including Concealed PVC conduit, fitting and accessories, junction boxes including one 1.5 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, making good, for One fan point controlled by one switch complete all as specified and directed
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixedin and including Concealed PVC conduit, fitting and accessories, junction boxes including one 1.5 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, making good, One 3 pin socket outlet 5 amps on same board controlled by one switch with 1.5 sqmm size cable complete all as specified and directed
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixedin and including Concealed PVC conduit, fitting and accessories, junction boxes including one 1.5 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, making good, for One 3 pin socket outlet 5 amps controlled by one switch on independent board with 1.5 sqmm size cable complete all as specified and as directed..
M&L for point wiring complete with 4.0 Sqmm single core multistranded copper conductor, FRLS PVC insulated unsheathed cable 1100 volts grade fixedin and including Concealed PVC conduit, fitting and accessories, junction boxes including one 4.0 Sqmm copper FRLS PVC insulated unsheathed earth continuity conductor connected in the common earth, making good, for One 3 pin socket outlet, 15 amps / AC Metal Clad, controlled by one switch on independent board with 4 sqmm size cable complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed PVC conduit, fitting and accessories, junction boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth complete all as specified and as directed including taking down existing point wiring for Light/ Fan/ Exhaust fan/ Independent 5 A Socket/ Security light complete all as specified and as directed.
All as per item No. 108 above but with 2.5 sqmm Single core wiring for Phase, neutral and earth for Independent 15 Amps power socket complete all as specified and as directed.
S&F Modular Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed.
S&F Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed.
S&F Modular Socket 5/6 Amps, 2 Module 2 and 3 pin complete all as specified and as directed.
S&F Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed.
S&F Modular Fan Regulator Step type, 2 Module 1 Way complete all as specified and as directed.
S&F 3 Module Cover Plate with frame and Metal Flush Box complete all as specified and as directed.
S&F 6 Module Cover Plate with frame and Metal Flush complete all as specified and as directed.
S&F 8 Module Cover Plate with frame and Metal Flush complete all as specified and as directed.
S&F 12 Module Cover Plate with frame and Metal Flush complete all as specified and as directed.
S&F Ceiling rose, 3 plate /PVC/ polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs 4 Feet LED Tube light of 20 Watt Batten with integrated electronic driver having THD < 20%, Burning hours not less than 50000 Hrs and aluminium housing with necessary fixing screws, and connected upto ceiling rose with flexible multicore copper cable and making Good complete all as specified and as directed.
S&F in repairs 2 Feet LED Tube light of 10 Watt Batten with integrated electronic driver having THD < 20%, Burning hours not less than 50000 Hrs and aluminium housing with necessary fixing screws, and connected upto ceiling rose with flexible multicore copper cable and making Good complete all as specified and as directed.
S&F in repairs SPN DB Double door 4 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed
S&F in repairs MCCB VTPN DB Double door 6 way with tray for provision of MCCBs as incomer and MCB as outgoing, neutral dolly, earth dolly, complete all as specified and as directed (Entrance)
S&F MCCB Four Pole 63 Amps, 16 kA, Fixed type complete all as specified and as directed.
S&F in repairs MCB Two Pole 63 Amps, 10 kA, C Curve complete all as specified and as directed.
S&F in repairs MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed.
S&F in repairs MCB Single Pole 63 Amps, 10 kA, C Curve complete all as specified and as directed.
M&L for submain wiring with two run of FRLS single core cable PVC insulated unsheathed cable 1100 volts grade 16 Sqmm copper multistranded conductor including and drawing into Concealed PVC conduit, fixed on wall, ceiling including one run of 16 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth, making good, complete all as specified and as directed. Note :- Three run of 16 sqmm cable and one run of PVC Conduit shall be measured as one Rm (For UPS in server Room)
Taking down carefully ceiling fan complete of any size and capacity, Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and refixing the same complete all as directed and as specfied.
Taking down carefully exhaust fan with louver complete of any size and capacity, Painting of fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and refixing the same fan with new louver complete all as directed and as specfied.
S&F AC metal Cald Socket with Plug and SP MCB 20 Amps complete all as specified and as directed.
M&L for Earthing complete with GI Earth Plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with GI wire of 4 mm dia by means of nuts/bolts/ check nuts/ wahers , GI pipe light grade of 15 mm bore as protection pipe, GI Strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
S&F taking down of ceiling fan complete, removing the down rod of exisiting length and providing new down rod/ Pedent of length not less than 1.5 mtr, brass with cord grip pattern, and 0.5 sq.mm copper flexible twisted twin cord up to 1.5m length for refixing ceiling fan. complete all as specified and directed.
S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, fixed on/in wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed. Note :- Three run of 4 sqmm cable and one run of PVC Conduit shall be measured as one Rm Note: From Main DB to Office DB
S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 1.5 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, fixed on/in wall, ceiling including 1.5 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed. Note :- Three run of 1.5 sqmm cable and one run of PVC Conduit shall be measured as one Rm Note: From Main DB to Office DB
S&F in replacement submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, fixed on/in wall, ceiling including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed. Note :- Three run of 6 sqmm cable and one run of PVC Conduit shall be measured as one Rm Note: From Main DB to Office DB
S&F in replacement Metal Clad enclosure with Socket and earth plug alongwith one Double Pole MCB 25 Amps, C Curve, 10 kA, Complete all as specified and as directed..
Supply & fix Heavy duty Exhaust fan, AC single phase 230/ 240 V of size 450 mm sweep, 900 RPM with louver,Complete all as specified and as directed.
Making a circular hole on Existing BrickWall at height less than 3mtrs from floor, and making good with proper plastering, paint to match the surrounding walls for fixing of 450mm exhaust fan. Note: The demolished PCC material should be removed at a distance not less than 50mtrs from the colony.
S&F in repairs MCB DB Double Door, TPN 06 way IP 54, fixed to wall in concealed by distrubing the exisitng wall surface and making good complete all as specified and as directed.
S&F MCB FP 100 Amps, C Curve, 10 kA, Complete all as specified and as directed.
S&F MCB TP 63 Amps, C Curve, 10 kA, Complete all as specified and as directed.
S&F MCB DP 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
S&F in replacement of exisiting Bldg Security light with 25 Watt LED New generation energy saving and environmental friendly long life light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 alongwith three core flexible copper connecting cable from light fitting to ceiling rose / connector complete all as specified and as directed.
S&F in replacement of GI Pipe bracket of dia 25 mm and length 1.5 RM bent to an angle as specified along with 2 Nos Clamps made upof FI 20x3 mm and fixed to wall complete all as specified and as directed.
Total of Schedule 'A'
DHANA CONSTRUCTIONS
G V N R CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .