Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.6 L+₹5,450.40 (0.25%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹22.4 L+₹79,148.46 (3.67%)Rejected-Finance 0 NEAR SATYANARAYAN SOCIETY GAYATRI MANDIR ROAD 0 BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L3 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹43,500
Closing Date
12 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BHUJ
GE AF BHUJ KHAVDA ROAD BHUJ KUTCH 370001
CONSTRUCTION OF WASHROOM FOR LLTR UNIT TOILET AT UNIT MI ROOM AT 308 TRU TOILET AT MILAN STHAL AND CERTAIN REV WORKS AT AF STN BHUJ
2020_MES_385954_2
8775/V/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF BHUJ
₹43,500
Yes
2 Feb 2021
28 Nov 2020
15 Dec 2020
28 Nov 2020
12 Dec 2020
28 Nov 2020
60 days
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Soft / loose soil complete all as specified and directed.
Excavation in trenches nt exc. 1.5 mt depth in any type of soil and getting out complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in Hard/Dense soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches exc 1.5 m wide and not exc 3.0 Mtr deep and getting out in soft/ loose soil complete all as specified and directed.
M & L PCC (1:4:8) type D2 for mass concrete and foundation filling complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil or hard dense soil.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L Reinforced cement concrete (design mix M 30) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified directed.
M&L Reinforced cement concrete (design mix M 30) as in Columns, pillars, piers, posts and struts complete all as specified directed.
M&L Reinforced cement concrete (design mix M 30) as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified directed.
M & L for RCC M-30 design mix as in slabs supported on walls ,beams and column in floors, roofs the like complete all as specified directed.
M&L Reinforced cement concrete (design mix M 30) as n Chajjas complete all as specified directed.
M & L Form work for fair finished surfaces of concrete measured flat for sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work.
M & L Form work for fair finished surfaces of concrete measured flat for sides of pillars, posts, struts, piers, columns and stanchions
M&L for formwork to sides and soffits of suspened slabs such as roof slabs, floor slabs, ladings and similar work, not exc. 200mm thick (horizontal or sloping) finished even and fair.
M&L, Formwork to edges of concrete in roof, chajja etc exc 10cm and n.exc 20cm wide complete all as specified and directed.
Use and waste of formwork, rough finished to flat sides and soffit of floor / roof beams, lintels, cantilivers, shelves etc complete all as specified and directed.
Use and waste of formwork, rough finished to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
S & F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 8 above but 6 to 8mm dia
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L 25mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) in floor as base of flooring
M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified.
M & L for Glazed ceramic coloured tiles in vertical surfaces 350x250x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:4 as in backing coat for tiles.
M&L for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement as specified.
M&L for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of Birla White Putty by finishing the surfaces even and smooth complete all as specified and directed by EIC.
M&L for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces.
M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cement sand mortar 1:4 on fair faces of brick work, PCC block masonry or concrete surfaces, mixed with water proofing compound as per manufacturer's instructions. (Note:- Supply only Integral water proofing compound will be measured and paid seperately)
Supply only integral water proofing compound.
M&L for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer all as specified and directed by EIC.
M&L for Providing Precast cement concrete block masonry type 1:5:8 using 20mm graded aggregate with solid blocks, exc 10 cm width and setting in CM 1:6 complete.
M&L for aluminium window with double side hung shutter for glazing and gauging and frame with one or more rebates made out of JINDAL/ INDAL anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle and anodised aluminum fittings such as stay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) all as specified and directed.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under above item shall be measured and paid separately
Supply , fabricate & fix anodised (15 micron) aluminium sliding windows/ ventilators made out of Jindal/Hindalco Aluminium sections as in frames , sliding/ fixed shutters etc. With one or more rebates incl. Jointing cleats & locking arrangements complete all as specified & as per manufacturer's instruction. Note- Quoted rate shall deemed to be included for supply of aluminium sections, fabricate & fixing in position of window frames & shutters, locking arrangements complete.
Supply only aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mm made out of standard aluminium moulded section of size 6mm x 7mm
M & L rubber beading for fixing of glass of item above complete.
S&F PVC door PDS-01 comprising of shutter and frame of Make : Accura Polytech Pvt Ltd (Accucel) all as shown on drg No.CEAA/TD/149 sheet No. 1/1 (PVC RIGIDE FOAM) , door frame/ chowkhats of solid rigid foam profile FP-6030 and shutter of solid PVC foam profile FP 7114 with 4 mm thick high pressure compact laminate as infill (Panel) including necessary hardeware fittings all as specified and directed by EIC.
S&F Vitrious china wash down water closet pan (pedestal pattern) white ( Excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous china urinal bowl flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe and water sprayer for flushing (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. Make - Cera Cat No-S4020101 Urinal Flat Back Large ISI marked or equivalent in Hindware all as directed by EIC.
S&F of waste pipe of 32mm dia PVC pipe for WHB with long screwed shanks and fly nut flange end beddedd in red lead cement and other end fixed
S&F stop valve 15 mm dia cast chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed
S&F stop valve 20 mm dia cast copper alloy type screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed
S&F pillar taps of 15 mm bore, fancy type with capstan head, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe & fixed.
S&F bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size 15mm bore.
S&F Aluminium anodised tubular towel rail 20mm dia D Type 60cm long between flanges
S&F PVC connection 450mm long with check nut for wash hand basin etc complete
S & F for Jet Spray to EWC with PVC nozzle, PVC fish plates and PVC flexible pipe etc complet all as specified.
S&F of UPVC drain self it pipes, single sockets ISI marked IS 13592 type 'B' in any length, jointed with solvent cement fixed in walls and the dia of pipes ( make :- Astral type 'B' pipes or equivalent)
110mm dia of pipe
75mm dia of pipe
S&F of UPVC junction single 'Tee' ISI marked IS 14735 jointed with solvent cement fixed in walls and the dia of pipes ( make :- Astral type 'B' pipes or equivalent)
110mm dia of pipe
75mm dia of pipe
S&F of UPVC sockets equal ISI marked IS 14735 jointed with solvent cement fixed in walls and the dia of pipes ( make :- Astral type 'B' pipes or equivalent)
110mm dia of pipe
75mm dia of pipe
S&F of UPVC bend equal ISI marked IS 14735 jointed with solvent cement fixed in walls and the dia of pipes ( make :- Astral type 'B' pipes or equivalent)
110mm dia of pipe
75mm dia of pipe
S&F for Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) 125mm size
Rotational moulded polyethylene water storage tanks 500 ltr capacity hoisted and fixed in position all as specified in SSR Part-I and including 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms)
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 750Ltrs capacity hoisted and fixed in position all as specified in SSR Part-I and including 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms)
S & F Rotational moulded poly ethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 Ltr with embossed ISI mark hoisted and fixed in position all as specified in SSR Part-I including taking out existing tank and including 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms)
M&L 150 mm dia RCC NP 3 dia pipes laid on 150 mm thick bed with excavation in any type of soil incl manholes/drop manholes of standard size made of PCC block masonry with SFRC ventilating cover and frame complete with depth of MH 0.70 m to 1.65 m deep.
M&L moorum / red bajri filling in floor and paving laid in layers not exc 15CM thick spread leveled and rammed inlcuding watering complete all as specified and directed.
M&L hard core of broken bricksof guage n.exc 63mm deposited spread and levelled in levelled in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L PCC 1:3:6 type C1, 75 mm thick finished even and smooth without using extra cement as in plinth protection including forming of joints 10mm wide and 75mm deep and joint filled with bitumin and sand mixture in 1:1 ratio complete all as specified and directed.
M&L, Rendering 15 mm thick in cement mortar 1: 6 on other than fair face of brick work finished even and smooth without using extra cement complete all as specified and directed.
M&L Preparing new surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L Preparing new surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
S&F, 20 mm bore gun metal globe / gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F, 75 mm dia out let PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed.
S&F vitreous china wash down water closet pan (pedestal pattern)(wall hung type) white (excluding, flushing cistern and flush pipe) complete connected to drain make : CERA, Cat No - 2033 & 2315.
S&F Vitrious china squattin pan ,Orrissa Paattern Size 580x440 mm white with integral foot rests ( Excluding flushing cistern and flush pipe)
S&F vitreous china urinal bowl flat back, size of 325 x 310 x 420 mm white (minimum), with grating and union for discharge pipe and water sprayer for flushing (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. Make - Cera Cat No-S4020104 Urinal Flat Back Large ISI marked or equivalent in Hindware all as directed by EIC
S&F, LDPE pipes of pressure rating 6Kgf/Cm Square fixed complete incl all fittings to wall and ceilings or in floors of 32 mm bore complete all as specified and directed.
M&L, cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc complete all as specified and directed.
S&F chromium plated toilet paper holder. Make Jaquar, Cat No AQN-7751.
S&F CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of Make : Astral or equivalent of Supreme / Finolex)
20mm nominal dia of pipes
25mm nominal dia of pipes
32mm nominal dia of pipes
M&L for 75 mm thick cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate as in sub base under interlocking tiles.
M &L Sand filling under floors or in foundations including watering and consolidation
M&L 60 mm thick M 35 Grade machine pressed precast concrete inter locking paver block with grey cement and no pigment any shape and size conforming to IS 15658-2006 laid dry over sand cushion complete all as specified and as directed
Cutting to existing manholes for connecting new drains, making good to pipe in 150 mm dia bore rendering cutting out existing benching for forming branch channel (1/2 or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid in trenches for 150 mm SWG pipe.
M&L , 150 mm bore , Salt glazed stone ware drain pipes, grade 'A', laid in trenches and jointed in CM 1:1 including testing complete all as specified and as directed.
M & L Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.2 M dia X 3.0M deep. complete all as specified and as directed.
M & L for replacement of 18-20mm thick pre polished (mirror) granite slab (with exposed edge duly grind and mirror polished) laid on kitchen platform top, window cill, steps, jambs and like set in neat cement slurry over and including 15mm thick screed bed in CM 1:4, pointing in white cement with pigment to match the stone all as specified and directed by Engineer -in -Charge.
M & L for 5mm thick rendering in cement mortar 1:4 (using water proofing compound @ 3 % by weight of cement) finished even and fair, over 10 mm thick rendering in cement mortar 1:6 on fair faces of concrete or block masonary all as specified and directed. Note: WPC shall be measured and paid seperately.
M & L for preparation of new external surfaces of walls including brooming down and applying a coat of thin layer of wall care putty and two coats of weather proof exterior emulsion paint, over a coat of primer as per manufacturers instructions etc complete all as specified and directed by Engr-in-charge, Make :- Nerolac (Exel), Asian 'Apex", Dulux " Weather shield water proof", Berger "weather coat all guard'.
All as per item No.77 above but on soffits of chajja, roof projection like surfaces
M&L, water proofing treatment on roof and preparing the surfaces to receive WPT treatment , applying cold bituminous primer @ 0.30 ltr / Sqm conforming to IS 3384 applied on plastered surfaces including side walls , followed by a layers of APP based polymeric membrane reinforced with polyster non woven fabric (weighing 3.5 Kg/Sqm(minimum) and 3 mm thick) with mineral finish laid on primed surface by torch application with side overlap 100 mm and ends over laps 150 mm , joints sealed properly as per manufacturers instructions all as specified and directed . Make- Tikidan Hydrostop Plus 3PY-M or equivalent as approved by GE.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors/wall.
All as per item No 34 above but 75mm bore
S & F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete as specified and directed.
S & F PVC (SWR) gully trap 125x110mm, setting and jointing with solvent cement all as specified and directed.
S & F PVC (SWR) 'P' trap 110x110mm, setting and jointing with solvent cement all as specified and directed.
S&F of PVC bend equal of any radius with door, ISI marked, IS-14735, jointed with solvent cement for 75mm size pipes. (Make : Astral type 'B' pipes or equivalent)
S&F of UPVC bend equal of any radius without door, ISI marked, IS-14735, jointed with solvent cement for 110mm size pipes. (Make : Astral type 'B' pipes or equivalent)
S&F of UPVC socket reducer 110mmx75mm size, ISI marked, IS-14735, jointed with solvent cement.(Make : Astral type 'B' pipes or equivalent)
S&F of UPVC cowl for 75mm size pipes, ISI marked, IS-14735, jointed with solvent cement. (Make : Astral type 'B' pipes or equivalent)
S & F 20mm bore Gun metal gate/globe valve, Heavy duty (ISI Marked) with iron wheel head, screwed both ends for iron pipe or for union and fixed complete all as specified & directed by Engineer-in-Charge.
S & F jet spray chromium plated 600mm long suitable for 15mm dia pipe and for European type complete all as specified and directed by Engineer-in- charge.
S & F Viterous china Wash Hand basin angle back of size 600 x 480mm white, excluding taps, waste chain plug and porcelain stopper but including brackets brass chromium plated, 32mm waste fittings and 15mm size PVC connection complete all as specified and as directed.
S & F Vitreous china wash down water closet pan (pedestal pattern) EWC including PVC seat cover closed pattern with hinging device and with jet spray with one metre long flexible pipe, all fittings complete all as specified and directed.
S & F 10 Ltr capacity PVC valveless, symphonic action type, flushing cistern low level, white, with inlet ball valve, float and handle including brackets, flushing pipe of suitable length and making good to floor/wall complete all as specified.
S & F brass CP tubular towel rail 20mm dia D Type 60cm long between flanges (heavy duty).
S&F soap dish stainless steel, heavy duty any type fixed to plugs with chromium plated brass screws.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface getting in soft/loose soil.
M&L for providing cement concrete 1:2:4,type B2 (40mm graded aggregate] in foundations, filling and mass concrete.
S&F mild stel for wind ties for roof including securing bolts ,incuding cutting tops to shape as directed , drilling holes and similar works conforming to Fe-290 Gde E-165
M & L for cement concrete Type B-2, 75mm thick 1:2:4 ( (using 20mm graded aggregate) for flooring.
S&F Steel work in tubular trusses including special shaped washer etc. Complete using ERW of induction butt welded tubes conforming to IS 1161-1998 grade St-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment GDE Fe 410-S complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n exc 10 cm and dia 11 to 15 mm complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
Ditto but plain sheets as in ridges etc
M & L for preparation of new steel surfaces and applying two coats of syanthetic enamel paints over a coat of red oxide primer of any girth & any description over 10cm in width or girth,not otherwise described complete all as specified & directed by EIC.
M & L for PCC with type D-2 1:4:8 (40 mm graded aggregate ) 100 mm thick as in sub base.
M&L for 100 mm thick cement concrete (1:2:4) type B2 (using 20mm graded aggregate) in pavement/hard standing including finishing the surfaces by brooming.
Forming construction(Dummy) joints 35 mm deep x 10 mm wide filled with sealing compound Grade B complete all as specified and directed.
Demolition of PCC block masonry built in cement mortar
S&F 35 mm thick second class H W , Plain Framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12mm veneered pariticle board with commercial veneering on bothe faces. The size of rail and stile as per IS: 1003 (Part -I), Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Aluminum anodised Tower Bolt 200mm long, of extructed section and fixed, complete all as specified and as directed.
S & F 300 MM Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of shedt, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed and complete all as specified.
S&F 105x60mm,1.25mm thick pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified including filling in frames with cement concrete type B-0, 1:2:4 (using 12.5mm graded aggregate)
M&L for cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in bed blocks for fixing of hold fasts and the like including necessary formwork.
M&L for preparation of new sufaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces.
M&L for preparation of new sufaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces.
M&L for exhaust fan,Metal body AC single phase 230/240V of size 230/250 mm sweep with sturdy metal body with metal blades,Double ball bearings heavy duty motor, corrosion resistant coating on blade & body and metal bird screen for protection from birds & foreign matter of 1350 RPM with input voltage 50W with 3 No. of blades all as directed by Engineer-in-Charge. Make:Havells or Equivalent in Bajaj//CG/Usha. Note:- (1).The rate quoated shall be in including making holes of suitable for exhaust fan of size 300 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4) on wall with two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including PVC casing capping and conduct including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:- Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately.Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.
One light point controlled by one, one way switch single pole.
One Fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket out let on independent board
S&F modular switch one way, 6 Amp, 1 module ISI Mark make Polycab Cat Part No.SLV3100601/02 or equivalent make of Anchor,Havells all as specified and directed by by Engineer-in-Charge.
S& F modular socket 6 Amp, 5 pin, combined 2 module, ISI marked make -Polycab Cat Part No.SLV0200201/02 or equivalent make of Anchor,Havells all as specified and directed by Engineer-in-Charge.
S& F modular white cover plate with frame 3 module ISI marked make - Polycab Cat Part No. SLV3200301 or equivalent make of Anchor,Havells all as specified and directed by Engineer-in-Charge.
S& F modular white cover plate with frame 4 module ISI marked make - Polycab Cat Part No.SLV3200401 or equivalent make of Anchor,Havells all as specified and directed by Engineer-in-Charge.
S&F Modular Metal flush box 3 module including cutting the GI Sheet/Plywood/wall ISI marked Polycab Cat Part No.SMB0100074 or equivalent make of Anchor,Havells all as specified and directed by Engineer-in-Charge.
S&F Modular Metal flush box 4 module including cutting the GI Sheet/Plywood/wall ISI marked Polycab Cat Part No.SMB0100075 or equivalent make of Anchor,Havells all as specified and directed by Engineer-in-Charge.
Supply and fixing Integral Sleek extruded polycarbonate LED channel with white acrylic cover 18 Watt 4 ft LED batton fitting as per Havells Cat part no. LHEXBTP7IN1W018 LED Fitting complete prewired including provision of 2core copper conductor flexible wire from ceilling rose to light fitting or equivalent Surya /Bajaj/ Havells/Orient/Polycab/CG all as directed by the engr-in-charge.
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V, 4 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/Polycab/Standard/Havells/Indoasian.
S&F isolators of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) for the following :-
(a) MCB SP of 240 volts 5-40 Amps Capacity, 'C' series 10 KA
(b) MCB, SPN of 240 volts 6 to 40 Amps 40 Amps Capacity, 'C' series
(c) MCB TPN 415 volts 63 Amps Capacity,'C' series ,10 KA
(d) MCB TPN 32 of 240 volts 5-40 Amps Capacity, 'C' series
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 25x4mm as earth lead up to 7.5 mtr length by means of bolts, nuts check muts and washers etc. of galvanised iron or steel all as shown in electrical plate No. 3 including provn of GI protection pipe light grade of 32mm bore upto 7.5m length and connected earth strip to earthing test point all as shown in electrical plate No. 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc.
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) Note:- .Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 not exceeding 10 cm grith & painting same so as to match the existing wall.
S&F switch piano flush type, 5 Amp. SP, one way with plastic enclosure for switch ISI marked all as specified and directed by Engineer-in-Charge.(Make:-Anchor,Havells,Polycab,Legrand)
S&F switch socket combination multi purpose 2 in 1, 5 pin 5 Amps, flush type, ISI marked all as specified and directed by Engineer-in-Charge. (Make:-Anchor,Havells,Polycab,Legrand)
S&F Sheet metal enclosure MCB TPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 440V, 4 Way with 200 Amp shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/Polycab/Standard/Havells.
M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
M & L unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable.
Supply and fix GI tubing light grade with all fitting laid in trenches or fixed on wall walls or poles for cable protection complete all as specified of size 40 mm bore .
S&F LED building security light, pressure die cast aluminum housing, 25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 32 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from ground with MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.Model :-ENDURAPEARLSL20WLED757SASYTOPCMP of Make:-Havells OR Equivalent in Philips/Wipro/Polycab/Orient. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
S&F ceiling rose surface bakelite 65mm x 50mm three terminal all as specified and directed
Supply and Fixing in repairs wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation integrated electronic driver T5 slim LED light fittings flicker free, instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells/ Orient/Philips/Bajaj/CG all as directed by EIC.
S & F of 40 watt LED street light luminaries comprising of cast aluminium housing, toughned glass, IP 65 and wired with all accessories enclosed with glass cover in frame including suitable size of street light bracket complete all as specified and directed. Make: Orient cat No.LSFS-040-CF or equivalent.
Supply and fix cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) of size 25 Sqmm 3.5 core 1100 Volts grade with stranded aluminium conductor of complete all as specified and directed.
supply and fix PVC weather proof flat twin core cable of size 10 sqmm 2 core stranded aluminium conductor passing through PVC pipe of suitable size complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6.3 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE/GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore , wire mesh and lugs, test point etc. complete. Note: G I strip exceeding 7.5m long shall be measured & paid seperately.
M&L for exhaust fan Metal Body, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of 300 mm dia in PCC block masonry wall, making good the side of hole and distributed surface with CM (1:4) to fix the Exhaust fan all as directed by Engineer-in-Charge. Make:- Bajaj/Havells/CG/Usha (1).The rate quoated shall be in including making holes of suitable for exhaust fan of size 300 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4) on wall with two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard.
Material and labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5mm FRLSH PVC insulated unsheathed copper earth wire including Suitable for switches and sockets complete all as specified and directed by Engineer-in-Charge.
One light point controlled by one, one way switch single pole.
One Fan point controlled by one, one way switch single pole.
One 3 pin 5 Amp socket outlet on the same board .
S&F switch socket combination 2 in 1 , 5/15 Amp, flush type, ISI marked all as specified and directed
Supply and fixing surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with white acrylic cover 10 Watt 2 ft LED batton fitting as per Havells Cat part no LUMILINEPLUSBS10WLED865SPCSS LED Fitting complete prewired including provision off 3 core copper conductor flexible wire from ceilling rose to light fitting or equivalent Surya /Bajaj/ Orient/Polycab all as directed by the Engr-in-charge.
M&L for XLPE insulated,armoured LT cable under ground cable 1100 volts grade with stranded aluminium conductor of size 16 sq mm 2 core electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed by the Engineer-in-Charge of following Sizes:- Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule "A" .
S&F 32mm bore Galvanised iron tubes light grade for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply And Fixing CPVC pipes 20mm Dia SDR-11 & Plain CPVC SDR-11 with all fittings on wall/ceiling or Laying in Floor/Wall complete with proper Steel Saddling of Half Meter apart of each complete all as specified and directed.Make:-Astral/Supreme/Finolex
Supply and Laying Pipes galvanized Medium grade laidin trenches complete including fittings 20 mm (3/4”) dia.
Supply and Fix 20mm (3/4”) dia. bore gun metal gate/globe valave with iron wheel head screw both ends for iron pipe or for union and fixed complete specified and directed by Enge-in-charge
Material and labour for Cutting existing steel / DI tubing of size upto150mm for alterations/ Water Tapping or additions and insert Tee of suitable size all as directed by Engr-in-charge. (Each cut measured)
BHAVANI PROVISION STORES
SHREE BHANU ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .