| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹33.1 L+₹3.0 L (9.96%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹34.4 L+₹4.3 L (14.3%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹38.6 L+₹8.5 L (28.2%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L4 | Rejected-Finance HIGHER BID | |
| 5 | L5₹42.0 L+₹11.9 L (39.4%)Rejected-Finance VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L5 | Rejected-Finance HIGHER BID |
| Sl No | Description | Qty | Unit | M/s Bombay Novelty Stores L2 | Abhishek Enterprises L4 | Pelectricals L1 | JYOT ENTERPRIES L3 | NAGEL ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in replacement of Street light fitting in new generation energy saving environemental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 9000 or higher , system effiency 100-120 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, 1 LED shoud be 1 to 3 watt, impact, IK7 or higher and capacity 90 Watt,including GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories required to fix the bracket on pole or wall , angle of bracket as per manufacture or site requirement complete all as specified and directed. | 100 | Each | 3,600 ₹3,60,000 | 5,500 ₹5,50,000 | 3,500 ₹3,50,000 | 3,290 ₹3,29,000 Lowest | 5,000 ₹5,00,000 |
| 2.00 | Supply and fixing in replacement of Street light fitting in new generation energy saving environemental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 9000 or higher , system effiency 100-120 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, 1 LED shoud be 1 to 3 watt, impact, IK7 or higher and capacity 60 Watt,including GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories required to fix the bracket on pole or wall , angle of bracket as per manufacture or site requirement complete all as specified and directed. | 140 | Each | 3,000 ₹4,20,000 | 4,500 ₹6,30,000 | 3,000 ₹4,20,000 | 2,350 ₹3,29,000 Lowest | 4,500 ₹6,30,000 |
| 3.00 | Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 200 Watt all as per manufacture recommendations & all connected accesories complete all as specified and directed. | 10 | Each | 7,000 ₹70,000 Lowest | 8,500 ₹85,000 | 7,950 ₹79,500 | 7,050 ₹70,500 | 10,000 ₹1,00,000 |
| 4.00 | Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 400 Watt all as per manufacture recommendations & all connected accesories complete all as specified and directed. | 4 | Each | 9,000 ₹36,000 Lowest | 22,000 ₹88,000 | 15,500 ₹62,000 | 13,950 ₹55,800 | 18,500 ₹74,000 |
| 5.00 | M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 1.50 Sqmm for connection drawing through pole or GI brackets from junction box to light conncecto of street light fittings complete all as specified and directed. | 500 | RM | 100 ₹50,000 | 135 ₹67,500 | 50 ₹25,000 Lowest | 72 ₹36,000 | 90 ₹45,000 |
| 6.00 | M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 2.50 Sqmm for connection drawing through pole or GI brackets from junction box to light conncector of street light fittings including heavy duty PVC conduit of size 20mm dia, lugs /thimbles according to size of cable complete all as specified and directed. | 500 | RM | 149 ₹74,500 | 190 ₹95,000 | 75 ₹37,500 Lowest | 135 ₹67,500 | 150 ₹75,000 |
| 7.00 | M & L rewinding of induction motor capacity 1.5 / 2HP Motor of high mast light after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including refixing and taking down complete all as specified and directed. | 1 | Each job | 6,000 ₹6,000 | 9,500 ₹9,500 | 5,000 ₹5,000 | 3,200 ₹3,200 Lowest | 6,000 ₹6,000 |
| 8.00 | Comprehensive maintanence of High mast light including repair of gear box , oiling of rope , repair of control panel for automatic /manual up/down of light assembly , replacemnt of electrical/mechanical parts for completion operation of light mast light complete all as specified and directed.(Note: (i) major working like rewinding of motor shall be measured and paid separately under relavent item of schedule.) | 3 | Each job | 8,000 ₹24,000 | 15,000 ₹45,000 | 10,000 ₹30,000 | 3,000 ₹9,000 Lowest | 10,000 ₹30,000 |
| 9.00 | Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 ,removing of old pole to side and refixing of MS channel , restringing of conductor, providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.) | 5 | Each job | 11,000 ₹55,000 | 10,500 ₹52,500 | 10,000 ₹50,000 Lowest | 17,900 ₹89,500 | 18,000 ₹90,000 |
| 10.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified & directed. | 2.7 | Cum | 300 ₹810 | 190 ₹513 | 160 ₹432 Lowest | 220 ₹594 | 1,000 ₹2,700 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jul 2025, 6:00 pmClosed
GE ARMY
BHUJ
REPAIR TO STREET LIGHT FITTINGS WITH CONNECTED ITEMS AT BHUJ AND CERTAIN EM WKS TO BLDGS AT MIL STN GANDHIDHAM UNDER AOR OF AGE EM OF GE ARMY BHUJ
2025_MES_717865_1
8329
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹80,000
Yes
24 Sept 2025
1 Jul 2025
31 Jul 2025
1 Jul 2025
29 Jul 2025
15 Jul 2025
Amount
Supply and fixing in replacement of Street light fitting in new generation energy saving environemental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 9000 or higher , system effiency 100-120 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, 1 LED shoud be 1 to 3 watt, impact, IK7 or higher and capacity 90 Watt,including GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories required to fix the bracket on pole or wall , angle of bracket as per manufacture or site requirement complete all as specified and directed.
Supply and fixing in replacement of Street light fitting in new generation energy saving environemental friendly long life LED street light with single die ceramic base high power LED light source,PDC housing with top openable access to driver for ease maintenance , lumen output 9000 or higher , system effiency 100-120 lm/watt , color temp 5700 K , made up of LM6 high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, 1 LED shoud be 1 to 3 watt, impact, IK7 or higher and capacity 60 Watt,including GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories required to fix the bracket on pole or wall , angle of bracket as per manufacture or site requirement complete all as specified and directed.
Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 200 Watt all as per manufacture recommendations & all connected accesories complete all as specified and directed.
Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 400 Watt all as per manufacture recommendations & all connected accesories complete all as specified and directed.
M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 1.50 Sqmm for connection drawing through pole or GI brackets from junction box to light conncecto of street light fittings complete all as specified and directed.
M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 2.50 Sqmm for connection drawing through pole or GI brackets from junction box to light conncector of street light fittings including heavy duty PVC conduit of size 20mm dia, lugs /thimbles according to size of cable complete all as specified and directed.
M & L rewinding of induction motor capacity 1.5 / 2HP Motor of high mast light after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including refixing and taking down complete all as specified and directed.
Comprehensive maintanence of High mast light including repair of gear box , oiling of rope , repair of control panel for automatic /manual up/down of light assembly , replacemnt of electrical/mechanical parts for completion operation of light mast light complete all as specified and directed.(Note: (i) major working like rewinding of motor shall be measured and paid separately under relavent item of schedule.)
Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 ,removing of old pole to side and refixing of MS channel , restringing of conductor, providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded aggregates) as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply and Fix tripod based revolving search light with 350 LED security search light , with long range , high intensity,weather proof, toughed glass, high conductvity heat sink, light should be adjsut for both vertical & horziontal operation control , tripod of minium height 01 meter,castor wheels complete all as specified and directed.
M & L for fixing, drawing 4mm dia galanized iron earth conductor between street light pole with and connceting 3 core cable from light fitting to conductor and inusulating tap should be covered over knot complete all as specified and directed.
Supply install testing,commissioning of CRI tested Copper earthing electrode of length 3 metres, 40mm dia and back fill compound of 50kgs ,and conductive gel to retain moisture should be filled layer wise and inter connceted by exothermic brazing & copper strip of size 32x6mm should be suppllied and fix upto testpoint protected by GI pipe of size 50mm dia up to test point including disconnection of old earth strip and fix to new chemical earthing, PCC earth pit of standared size as per SSR part-1 and submmision of earth results and painting of Date of test , value obtain at site complete all specified and as directed.
M & L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size complete all as specified and directed.
M&L for shifting of 10 meter high mast light pole to new location including removing existing LEDs light from light and refixing the same LED after the shifting all as specfied and directed. (Note: Excavation , PCC are measured separately.)
Labour only for checking the serviceability of different spares / components / parts of security light fitting/street light any wattage/capacity of any description and in position or by taking down the fitting, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fitting and making the light fitting serviceable, connecting to electric supply and its testing on installation complete all as directed by Engineer-in-Charge. NOTES : Contractor's quoted rates are deemed to be included the following : - (a) Removal of unserviceable / broken parts of fitting, fixing of new parts(driver) in replacement to make the fitting serviceable. New parts shall be measured and paid for separately as "supply only" against respective item of Sch ‘A’ and treated as one complaint. (b) Necessary T&P i.e. ladder, tools etc required for checking, making the light fitting in serviceable conditions including necessary screws, insulating tapes, internal wiring, gasket etc fixing in position and testing, of any description on poles / on walls / on pillars etc i.e. in any position. (c) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (d) when refreshing the cable, insulation tape should be done to avoid carbon.
Supply only LED driver for street light rating upto 45W complete all as specfied and directed.
Supply only LED driver for street light rating from 45W upto 90W complete all as specfied and directed.
Supply only LED MCPCB (LED chip) upto 45W complete all as specfied and directed.
Supply only LED MCPCB (LED chip) from 45 to 90W complete all as specfied and directed.
Supplying and fixing contactor for street light timer of rating 40 Amp 9AC-1) 4 pole,220 Volts,CN 325F complete all as specifed and directed.
Supplying and fixing digital Timer for street light timer of rating 40 Amp 9AC-1) 4 pole,220 Volts,CN 325F complete all as specifed and directed.
Supply and Fix single phase 230V,5 KW infrared based street light control panel ,IP 54 , with sintex SMC with incoming MCB complete all as specfied and directed.
Supply and fix 2 core aluminium service cale of size 4 sqmm complete all as specfied and directed.
Supply and fix 2 core aluminium service cale of size 10 sqmm complete all as specfied and directed.
Taking down carefully existing unserviceable aluminum/copper point wiring (light, fan, socket or power) of any description & in any position complete including all fittings & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed
M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size concealed type fixed on wall / fixed to surface ceiling with PVC rawl plugs with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
One light/buzzer point controlled by one; one way switch complete all as specified and directed.
One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per item No. 31 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed.
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular socket, 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed.
S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed.
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting complete all as specified and directed.
S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED lamp fitting complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for MCB DB SPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, Metal clad plug, distribution boards/main switches of any type and size and S & F sheet metal enclosure powder painted for vertical type MCB DB TPN 04 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Taking down carefully MCBs, metal clad plug, distribution boards/main switches of any type and size and Supplying and fixing sheet metal enclosure powder painted for MCB DB vertical type TPN 4 way double door with dinrail and busbar with IP-43 protection with door earthing and isolated neutral bar and insulated busbar assembly including MCCB of 100 Amps complete all as specified and directed.
Supply and fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conduit/casing capping including accessaries with 4sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up complete all as specified and directed.( Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.)
M & L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up complete all as specified and directed.( Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.)
Supply and laying Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 25mm dia complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core 0.5 sqmm flexible copper conductor cases of suitable size complete all as specified and directed.
M&L for Disconnecting,taking down and removing of ceiling fan / Exhaust fan / wall mounting fan of any description, any sweep and from any position / locations and connecting up from ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying nuts, bolts, canopy, down rod, clamps, capacitor and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed by accepting officer (Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.)
Description all as per ser item No 60 here in before but for exhaust/cabin fans of any size/make complete all as specified and directed. (Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.)
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete as directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
Supply only bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 250 to 450mm sweep/cabin fan of any size complete all as specified and directed.
Rewinding of exhaust fan 250mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan 250 to 450mm sweep of different make complete all as specified and directed.
Supply only rubber reel type synthetic rubberwith 14.5 mm hole suitable for hooks of celling fans complete all as specified and directed.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" length complete all as specified and directed.
Supply only top/bottom (Set of Two) canopy of required size complete with tightening screws complete all as specified and directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD complete all as specified and directed.
Supply only fan blade made out of M S sheet suitable for any make , sweep and colour of celling fans complete all as specified and directed.
Description all as per item No 71 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan complete all as specified and directed.
M & L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete all as specified and directed.
Supply only exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete all as specified and directed.
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed. (Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A". Supply only of following items for geyser complete.)
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size complete all as specified and directed.
(b) Geyser element 1.5 KW complete all as specified and directed. (Make :- Theata/Venus)
(c) Geyser element 2.0 KW complete all as specified and directed. (Make :- Theata/Venus)
(d) Thermostate switch ISI Marked complete all as specified and directed.
(e) S/S inner tank Capacity 25 Ltrs heavy duty complete all as specified and directed.
(f) S/S Copper inner tank capacity 06/03 ltr heavy duty complete all as specified and directed.
(g) Indicator lamp of any type/colour complete all as specified and directed.
(h) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces complete all as specified and directed.
(j) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified and directed.
(k) Copper flexible cable PVC insulated 3 core 40/.0076 complete all as specified and directed.
(l) Outer body but 25 ltr capacity Geyser sutaible for existing make complete all as specified and directed.
(m) Pressure release valve ISI marked complete all as specified and directed.
(n) Safty plug of geyser for 25/35/50 Ltr capacity complete all as specified and directed.
(o) Plug top 3pin 15 Amps ISI Marked complete all as specified and directed.
(p) Non return valve 15mm dia pipe brass made ISI marked complete all as specified and directed.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank etc, complete all as specified and directed.
(a) S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed.
(b) S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed.
(c) Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as specified and directed.
(e) Supply & fixing in replacement of capacitor 4 MFD complete all as specified and directed. (Make Usha/Universal/Epcos)
(f) Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness complete all as specified and directed.
(g) S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed.
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note :- (replacement of spare part will be measured and paid separately under appropriate items )
(a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of Upto 425 ltrs capacity.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only starting relay complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only capacitors of the following capactities for ACs water coolers, refrigerators, Deep freezers etc as per site requirement.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Water coolers 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only PCB of split type AC Cap 1.5/ 2 TR as per existing make and model complete all as specified and directed.
S & F in replacement of LED street light fitting 35 watt, 230 volt AC outdoor type with LM6 high pressure die ccast aluminium housing with toughned glass, impact and corrosion resistant incl thermal management in multiple optics, heat resistant complete with driver, lamp bracket made out of 25mm dia GI pipe medium grade 1.5 mtr long, angle of bracket as per site requirement, 02 Nos of clamps, nuts, bolts and washers complete with IP 66 protection complete all as specified and directed.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
M/s Bombay Novelty Stores (BID ID -3367421)
JYOT ENTERPRIES (BID ID -3376382)
Abhishek Enterprises (BID ID -3367506)
NAGEL ENTERPRISES (BID ID -3367010)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .