Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC INDUSTRIAL ESTATE PHASE III KHONMOH KHONMOH SRINAGAR JAMMU KASHMIR 191104 | 191104 | ₹3.9 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.1 Cr+₹15.7 L (4.01%)Rejected-AOC | ₹4.1 Cr+₹15.7 L (4.01%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹4.3 Cr+₹34.9 L (8.92%)Rejected-AOC | ₹4.3 Cr+₹34.9 L (8.92%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹5.7 Cr+₹1.8 Cr (45.8%)Rejected-AOC 106 DLF COMMERCIAL TOWER SHIVAJI MARG NEW DELHI | NEW DELHI | NEW DELHI | DELHI | 110015 | ₹5.7 Cr+₹1.8 Cr (45.8%) | L4 | Rejected-AOC Rejected |
| 5 | Rejected-Technical 0 KISHANI KISHANI KISHANI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | - | - | Rejected-Technical Technically Non Responsive |
| Sl No | Description | Qty | Unit | M/s AQUA ENGINEERS AND FABRICATORS L1 | M/S MIRI PIRI ENGINEERING COMPANY L2 | NATIONAL INFRA INDUSTRIES LIMITED L4 | LLOYD INSULATION (INDIA) LIMITED L3 |
|---|---|---|---|---|---|---|---|
| 1.00ACCOMODATION WORKS | |||||||
| 1.01 | Design, Providing and erection of prefabricated (Thermally Insulated) With 60 mm (Puf Insulated) walling double story shelters for office complex including plot leveling, development works, Sub soil investigation (SSI), Design and drawings to be approved by IIT/NIT, civil foundation, Walkway, Installation of steel structure with cladding. Mechnical, Electrical and telecom installation etc according to drawings and the direction of Engineer-in-Charge.
Additional requirements/Specification: -
(i) Roofing: Pre-painted GI Sheet (Min Thickness 0.50 mm)
(ii) False ceiling as per particular specification and approved design.
(iii) Doors and Windows as per approved design.
(iv) Flooring as per particular specification and direction of the Engineer-in-Charge.
(v) All electrical fittings (Quality as per direction of Engineer-in-Charge)
(vi) Water supply provisioning with 4 x 1000 Litre insulated tank and staging (3 to 4 mtr) above ground and plumbing work.
(vii) Sanitary works with provision of suitable septic tank.
(viii) A Gantry of 10 Ton capacity should be installed in working area having double storey height as per approval of the Engineer-in- Charge.
(ix) Miscellaneous works as per direction of the Engineer-in-Charge.
(x) Fixed facilities with building as per requirement of Wksp consisting of a Gantry crane.
(xi) Construction of two toilet blocks each consisting of 01xWC & 04 urinal pots respectively. | 1,444 | Sqm | 27,100 ₹3,91,32,400 Lowest | 28,186 ₹4,07,00,584 | 39,500 ₹5,70,38,000 | 29,516 ₹4,26,21,104 |
Tender Value
₹4.4 Cr
EMD Value
₹5.1 L
Closing Date
22 May 2026, 6:00 pmClosed
Chief Engineer, Project Vijayak
HQ CE (P) Vijayak, C/o 56 APO, Pin 931721
DESIGN, SUPPLY AND CONSTRUCTION OF PREFABRICATED DOUBLE STORY SHELTER FOR OFFICE COMPLEX FOR 1060 FD WKSP AT KARGIL UNDER 55 RCC / 762 BRTF PROJECT VIJAYAK IN LADAKH (UT)
2026_BRO_762916_1
CE(P)/VJK/02/2026-27
Open Tender
Civil Works
Item Rate
270 days
HQ 1060 FD at Kargil Ladakh
as per tender documents
8 documents required · 8 mandatory
₹0
₹5.1 L
Yes
HQ CE (P) Vijayak, C/o 56 APO
23 Jul 2026
1 May 2026
29 May 2026
1 May 2026
22 May 2026
15 May 2026
2 May 2026 - 12 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ACCOMODATION WORKS | |||||
| 1.01 | Design, Providing and erection of prefabricated (Thermally Insulated) With 60 mm (Puf Insulated) walling double story shelters for office complex including plot leveling, development works, Sub soil investigation (SSI), Design and drawings to be approved by IIT/NIT, civil foundation, Walkway, Installation of steel structure with cladding. Mechnical, Electrical and telecom installation etc according to drawings and the direction of Engineer-in-Charge.
Additional requirements/Specification: -
(i) Roofing: Pre-painted GI Sheet (Min Thickness 0.50 mm)
(ii) False ceiling as per particular specification and approved design.
(iii) Doors and Windows as per approved design.
(iv) Flooring as per particular specification and direction of the Engineer-in-Charge.
(v) All electrical fittings (Quality as per direction of Engineer-in-Charge)
(vi) Water supply provisioning with 4 x 1000 Litre insulated tank and staging (3 to 4 mtr) above ground and plumbing work.
(vii) Sanitary works with provision of suitable septic tank.
(viii) A Gantry of 10 Ton capacity should be installed in working area having double storey height as per approval of the Engineer-in- Charge.
(ix) Miscellaneous works as per direction of the Engineer-in-Charge.
(x) Fixed facilities with building as per requirement of Wksp consisting of a Gantry crane.
(xi) Construction of two toilet blocks each consisting of 01xWC & 04 urinal pots respectively. | 1,444 | Sqm | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
BOQ_854584.xls
BOQ • 0.26 MB
FinalTender02.pdf
Tender Documents • 12.31 MB
CorrgdmNIT021060FD.pdf
PDF • 0.08 MB
Corr02NIT02.pdf
PDF • 0.90 MB
CorrigendumNIT02.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .