Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC VILL 76 SUNIL POST JOSHIMATH DISTT CHAMOLI UTTRAKHAND 246443 | JOSHIMATH | CHAMOLI | UTTARAKHAND | 246443 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹18.6 L+₹3.0 L (19.0%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 3 | L3₹19.3 L+₹3.7 L (23.5%)Rejected-AOC SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC OTHER THEN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Bedi Refrigeration Works L2 | NOORI ELECTRIC ENGINEERING WORKS L3 | Shri Narayan Construction L1 |
|---|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS. | ||||||
| 1.01 | Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed.
Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ. | 5 | Each | 2,000 ₹10,000 | 1,400 ₹7,000 Lowest | 2,800 ₹14,000 |
| 1.02 | Replacement of old unserviceable/ damaged overhead conductor with new overhead, aluminium conductor, steel reinforced, weasel/ Squirrel, from any type/ height of poles including proper binding with existing insulators, complete all as specified and as directed.
Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc. | 3 | Per Quintal | 20,000 ₹60,000 | 19,999 ₹59,997 Lowest | 23,000 ₹69,000 |
| 1.03 | Replacement of old unserviceable/ corrosion GI earth wire with new galvanised iron wire as in earth wire or wire guard, cradles, hexagonal/ rectangular, fabricated with galvanised steel wire of 4.0mm dia from any position, LT poles of any type and any height including binding wire, 1.60mm dia, galvanised iron, complete all as specified and as directed. | 0.3 | Per Quintal | 12,000 ₹3,600 | 12,500 ₹3,750 | 10,000 ₹3,000 Lowest |
| 1.04 | Taking down existing unserviceable/ rusted structural steel in cross arms and replacement with new mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed. | 1 | Per Quintal | 12,000 ₹12,000 | 11,300 ₹11,300 | 9,500 ₹9,500 Lowest |
| 1.05 | Replacement of old unserviceable/ damaged shackle type insulator with new shackle Type, Porcelain, vitreous, white, brown or green insulator size 50mm height, 65mm dia including galvanised mild steel straps 25x1.59mm and insulator bolts of bolts 9mm dia, washers, nuts, for working pressure 550 volts grade, complete all as specified and as directed. | 40 | Each | 120 ₹4,800 | 60 ₹2,400 Lowest | 120 ₹4,800 |
| 1.06 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed. | 243 | Per Cum | 220 ₹53,460 Lowest | 400 ₹97,200 | 300 ₹72,900 |
| 1.07 | Excavation in trenches, not exceeding 1.50mtr wide and exceeding 1.50mtr but not exceeding 3.0mtr in depth; for foundation, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed.
Note: Stone retrieved from excavation shall be issued to contractor. | 0.8 | Per Cum | 300 ₹240 Lowest | 1,200 ₹960 | 500 ₹400 |
| 1.08 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. | 167 | Per Cum | 30 ₹5,010 Lowest | 100 ₹16,700 | 130 ₹21,710 |
| 1.09 | Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. | 77 | Per Cum | 30 ₹2,310 Lowest | 200 ₹15,400 | 180 ₹13,860 |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
26 Mar 2026, 6:00 pmClosed
GARRISON ENGINEER
GE 871 EWS C/O 56 APO PIN- 913871
REPAIR/ MAINT OF LT CABLE, MCCB AND OTHER MISC E/M CONNECTED WORKS IN THE AREA OF AGE B/R RUDRAPRAYAG UNDER GE 871 EWS
2026_MES_755472_1
8987/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RUDRAPRAYAG
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹46,000
Yes
8 Jul 2026
7 Mar 2026
28 Mar 2026
7 Mar 2026
26 Mar 2026
21 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS. | |||||
| 1.01 | Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed.
Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ. | 5 | Each | - | - |
| 1.02 | Replacement of old unserviceable/ damaged overhead conductor with new overhead, aluminium conductor, steel reinforced, weasel/ Squirrel, from any type/ height of poles including proper binding with existing insulators, complete all as specified and as directed.
Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc. | 3 | Per Quintal | - | - |
| 1.03 | Replacement of old unserviceable/ corrosion GI earth wire with new galvanised iron wire as in earth wire or wire guard, cradles, hexagonal/ rectangular, fabricated with galvanised steel wire of 4.0mm dia from any position, LT poles of any type and any height including binding wire, 1.60mm dia, galvanised iron, complete all as specified and as directed. | 0.3 | Per Quintal | - | - |
| 1.04 | Taking down existing unserviceable/ rusted structural steel in cross arms and replacement with new mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed. | 1 | Per Quintal | - | - |
| 1.05 | Replacement of old unserviceable/ damaged shackle type insulator with new shackle Type, Porcelain, vitreous, white, brown or green insulator size 50mm height, 65mm dia including galvanised mild steel straps 25x1.59mm and insulator bolts of bolts 9mm dia, washers, nuts, for working pressure 550 volts grade, complete all as specified and as directed. | 40 | Each | - | - |
| 1.06 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed. | 243 | Per Cum | - | - |
| 1.07 | Excavation in trenches, not exceeding 1.50mtr wide and exceeding 1.50mtr but not exceeding 3.0mtr in depth; for foundation, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed.
Note: Stone retrieved from excavation shall be issued to contractor. | 0.8 | Per Cum | - | - |
| 1.08 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. | 167 | Per Cum | - | - |
| 1.09 | Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. | 77 | Per Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
E-Tender.pdf
Tender Documents • 1.00 MB
BOQ_846190.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .