Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.4 LAccepted-AOC NANDNI VIHAR ADHOIWALA DEHRADUN | L1 | Accepted-AOC L1 | |
| 2 | L2₹54.9 L+₹1.5 L (2.76%)Rejected-Finance | L2 | Rejected-Finance See Attachments | |
| 3 | L3₹56.0 L+₹2.6 L (4.96%)Rejected-Finance | L3 | Rejected-Finance See Attachments |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
27 Jan 2021, 5:00 pmClosed
Executive Engineer
Office of Ex. Eng. Uttarakhand Jal Sansthan Ring Road Jogiwala Raipur Dehradun
Supply, Laying and Jointing of different diameter HDPE pipes with testing commissioning and proper completion of work at different colonies of Miyawala and Shamshergarh (Ward No- 68) including supply of all material, labour, T and P etc. complete
2021_UKJS_29118_1
952/E-Tender Notice/2020-21 dt 14.01.2021
Open Tender
Civil Works - Water Works
Item Wise
180 days
Dehradun
As per TD
3 documents required · 3 mandatory
₹5,900
Executive Engineer Uttarakhand Jal Sansthan Raipur
₹1.1 L
Dehradun
30 Oct 2021
22 Jan 2021
28 Jan 2021
22 Jan 2021
27 Jan 2021
22 Jan 2021
25 Jan 2021
Supply, Laying and Jointing of different diameter HDPE pipes with testing commissioning and proper completion of work at different colonies of Miyawala & Shamshergarh (Ward No- 68) including supply of all material, labour, T&P etc. complete
Dismantling of Concrete road during pipe laying including all labour, material, T & P etc. complete.
Excavation in earth work requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
Provinding, lowering into trenches with true to alignment, laying & Jointing of full lenghts of HDPE pipes of specified grade as Per IS: 4984-1995 and specification, with testing of pipe line including supply of jointing materials. PE- 63 Grade, PN- 6.00 kg/Cm2 HDPE Pipes (i) 110mm dia
2) 90 mm dia
3) 75 mm dia
4) 63 mm dia
Cartage of following pipes, specials & fittings from site store to the site of works, lowering them into trenches, laying true to alignment & gradient, laying & joining of pipe line including cutting & threading of pipe for making up lengths as required for proper completion of work. MSERW Line Pipe (4.80 mm Thick). Confirming to BIS: IS / ISO 3183 / 2007 (MSERW pipe will be provided by department) 1) 150 mm dia (by welding)
(ii) 100 mm dia
(iii) 80 mm dia
(iv) 65 mm dia
(v) 50 mm dia
Supply of all materials, labour, T&P etc. and construct the following valve chamber as per type design. (a) Sluice/Refluex vlave chamber 1.20M x1.20M x 1.00M
Interconnection of new pipeline to existing laid Pipeline (i) 150 mm GI to 150 mm dia MSERW
(ii) 150 mm MSERW to 110 mm dia HDPE
(iii) 150 mm GI to 110 mm dia HDPE
(iv) 150 mm MSERW to 90 mm dia HDPE
(v) 150 mm MSERW to 75 mm dia HDPE
(vi) 150 mm MSERW to 63 mm dia HDPE
(vii) 100 mm GI to 90 mm dia HDPE
(viii) 100 mm GI to 75 mm dia HDPE
(ix) 100 mm GI to 63 mm dia HDPE
(x) 80 mm GI to 63 mm dia HDPE
Provision for restoring of house connection and that might be damaged during excavation and laying of pipe line of existing connection.
Restoration of Cement concrete pavement in plain cement concrete in 1:2:4 ratio.
sushilprasad
M/s Shaurya Associate
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .