Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹23.3 L+₹2.4 L (11.5%)Rejected-Finance PLOT NO 86 SHIVAM PARK 2 AIR PORT ROAD BEHIND SANATAN MANDIR BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹23.8 L
EMD Value
₹47,600
Closing Date
12 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
REPLACEMENT OF BER SUMMER APPLIANCES AT AF STN BHUJ
2024_MES_682949_1
8774/V/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹47,600
Yes
16 Jan 2025
8 Nov 2024
14 Dec 2024
8 Nov 2024
12 Dec 2024
30 Nov 2024
11 Nov 2024 - 12 Nov 2024
Amount
Supply & install hi wall split air conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge.
Supply & install hi wall split air conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as specified and directed by Engineer-in-Charge.
Supply & fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with low and high cutoff facility including under and over current protection with accurancy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply & fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with low and high cutoff facility including under and over current protection with accurancy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engr-in-Charge.
Supply & fix PVC enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed by Engineer-in-Charge.
Material & labour for sub main wiring with two runs (two runs measured as one run) of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing caping of size width not less than 25 mm ISI marked with accessories to wall/ceiling with proper saddles and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge. (Note: Three runs of 4.0 sqmm copper cable including PVC casing caping will be measured as one RM)
Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour complete all as specified and as directed by Engineer-in-Charge.
Dismantling of split AC/window AC 1.5/2.0 TR and diposited to MES store complete all as specified and directed by Engineer-in-Charge.
Supply & installation of compact dehumidifier, moisture adsorption (process air flow) of capacity 300 CMH following with reactivation process of 100 CMH alongwith positive cealing between both chamber to prevent mixing of process and reactivation air stream, single phase 230 volts 50 Hz complete all as specified and directed by Engineer in Charge.
Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant complete all as specified and directed by Engineer in Charge.
JYOTI TRADERS (BID ID -3181302)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .