Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical GOVT E CONT VILL PATAN PO MATLAHAR TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical GHUMARWIN DIVISION HP PWD GHUMARWIN | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical HIMACHAL PRADESH | SHIMLA | HIMACHAL PRADESH | 171001 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹6,140
Closing Date
20 Feb 2026, 10:00 amClosed
Sr. Executive Engineer
ED HPSEBL Jawali
Tender for Supply of equipment/material, design, erection, testing and commissioning for SOP to JSV by prov. 11/0.4kv, 63KVA S/Stn T/Well Near Ram Kumar house a/w HT Line in (E) Sec. Bharmar UESD Jawali.
2026_HPSEB_128392_1
JED 137/2025-26
Open Tender
Supply and Erection
Turn-key
90 days
ED Jawali
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹6,140
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
11 KV HT Line
Prov. ACSR (6/1/3.35 50mm²) { Neutral conductor including 1% (Sag, Jumpering and wastage}
Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Prov. Muffs with concerete filling
X-Arm: [Channel Iron (75x40x6 mm), Length : (2340 mm X 4 Nos] for supporting DO fuse unit & GO switch
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side)
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 5 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
Prov. Pin Insulator with GI Pin
Prov. GO AB Switch Unit (11kV, 400A,) O/D type
Prov. D.O Fuse Unit
Prov.Stay set complete HT i/c Egg
Prov. Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) (Prov. By HPSEBL)
Prov. GI Wire 8 SWG. (Prov. By HPSEBL)
Prov. Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Prov. Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Prov. Danger Plate (250X200X1.6 mm) (Prov. By HPSEBL)
Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Prov. Aluminium Paint
Erection of 9 Mtr. ST pole Single structure i.e. digging of pit, fixing of insulator, x-arms, K.B. set, Top clamp, barbed wire, danger plate, drilling of holes and filling of pit + ramming complete in all respect.
Erection of Stay set HT i.e. digging of pit, fixing of stay road, filling of pit, nozzeling & tightning.
Erection of G.O. switch 400 Amp. Comp.
Sagging of conductor i.e. laying, stringing and sagging & binding with insulator (Single wire per KM).
Sagging of GI Wire i.e. laying, stringing and sagging & binding (Single wire per KM).
Transportation Charges & Mannual carriage of material 1 KM HT line considering average distance from road to site of work (0.100 Km)
63 KVA Trsanformer
Prov. Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA
Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Prov. Muffs with concerete filling
Prov. X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
Prov. MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
Prov. X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
Prov. Transformer Bed, Belting & Knee Bracing
Prov. X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
Prov. X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
Prov. MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
Prov. MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
Prov. Transformer LT Distribution Box and GO Switch fixing Assembly
Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
Prov. MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
Prov. GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
Prov. GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
Prov. D.O Fuse Unit
Prov. Lighting Arrester, 9 kV Station Class (Porcelain Type)
Prov. Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Prov. Stay set complete
Prov. Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set) (Prov. By HPSEBL)
Prov. Pipe Earthing Set
Prov. LT Distribution Panel Box With MCCB 100 amp 3P 35kA , ICS =100 % ICU, Kit-Kit 200 Amp
Prov. Half Clamp (M.S. Flat 50X6 mm)
Prov. Full Clamps (M.S. Flat 50X6 mm)
Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Prov. Aluminium Thimble (Prov. By HPSEBL)
Prov. Aluminium Thimble (Prov. By HPSEBL)
Prov. Danger Plate (Prov. By HPSEBL)
Prov. LT Cable (3.5 Core) 95 mm²
Prov. Energy Meter 3-ɸ, 4 wire CT operated Static Tri-Vector meter with Box(CT-100-200/5A)
Prov. Aluminum Paint.
Prov. Prov. 6/1/3.35, 50mm²
Erection of 63 KVA S/Stn. i.e. digging of pit for pole & earthing two No. poles & 3 Nos. for earth drilling of holes in X-arms, preparation of plateform str. Members C.I., A.L. i.e. X-arms & K.B. set, errection of D/P, concreating of RCC muff errection of plateform, errection of X-arms, D.O., L.A., MCCB, Switch LT box, energy meter, errection of transformer, earthing connection to G.O. switch, Transformer L.A. etc., errection of stay set, jumper, pipe earthing 3 Nos set, L.T. cable, barbed wire and painting complete in all respect.
Prov. Transportation charges of 63 KVA pole mounted distribution S/Stn.
Prov. Manual Carriage of 63 KVA Pole Mounted Distribution Sub Stn. Average Distance 1 km from road to site of work (0.100 Km)
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
SBD137.pdf
Tender Documents • 3.39 MB
BOQ_189692.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .