Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.9 L+₹18,982 (0.50%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹45.3 L+₹7.6 L (20.0%)Rejected-AOC 1062 C2 2 ND FLOOR OPPO NAJATH PUBIC SCHOOL MUNICIPALITY JUNCTION SOUTH KALAMASSERY ERANAKULAM KERALA 682033 | KALAMASSERY | ERNAKULAM | KERALA | 682033 | L3 | Rejected-AOC L3 |
Tender Value
₹39.7 L
EMD Value
₹50,000
Closing Date
12 Dec 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer
Chief Executive Officer Park Centre, Technopark Phase I Campus
DISMANTLING, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF BTU METERS AT TECHNOPARK PHASE I CAMPUS, PHASE III CAMPUS, AND KOLLAM PHASE V CAMPUS
2022_ETPK_533484_1
ETPK/PH-I/2022-23/AT-161
Open Tender
Miscellaneous Works
Item Rate
120 days
Technopark Phase I, Phase III and Kollam Campuses
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
₹50,000
26 Dec 2022
25 Nov 2022
13 Dec 2022
25 Nov 2022
12 Dec 2022
28 Nov 2022
26 Nov 2022 - 9 Dec 2022
Amount
DISMANTLING, SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BTU METERS AT TECHNOPARK PHASE - I CAMPUS,
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 25 (BMS Compatible – Mbus protocol) (Make:Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 40 (BMS Compatible – Mbus protocol) (Make:Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 50 (BMS Compatible – Mbus protocol) (Make: Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 65 (BMS Compatible – Mbus protocol) (Make: Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 80 (BMS Compatible – Mbus protocol) (Make: Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 100 (BMS Compatible – Mbus protocol) (Make: Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Installation, Testing and Commissioning of Ultrasonic BTU Meters DN25, DN40, DN50, DN65, DN80, DN100 at respective locations with necessary fittings including the pipe, insulations, fittings, etc. required for commissioning the units as mentioned in the tender document ETPK/PH-I/2022-23/AT-161
DISMANTLING, SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BTU METERS AT TECHNOPARK PHASE – III CAMPUS
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 65 (BMS Compatible – Mbus protocol) (Make:Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Installation, Testing and Commissioning of Ultrasonic BTU Meters DN 65 at respective locations with necessary fittings including the pipe, insulations, fittings, etc. required for commissioning the units as mentioned in the tender document ETPK/PH-I/2022-23/AT-161
DISMANTLING, SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BTU METERS AT TECHNOPARK KOLLAM PHASE – V CAMPUS.
Dismantling of existing BTU meter and supply of Ultrasonic BTU Meter, DN 50 (BMS Compatible – Mbus protocol) (Make:Landis+Gyr, Shenitech, Kamstrup, Engelmann.) The service pipe insulation shall be polyurethane foam (make seven star or equivalent to be approved by the consultant) with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft/F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket.
Installation, Testing and Commissioning of Ultrasonic BTU Meters DN50 at respective locations with necessary fittings including the pipe, insulations, fittings, etc. required for commissioning the units as mentioned in the tender document ETPK/PH-I/2022-23/AT-161
Deltat Engineering Solutions
Cadillac Automation and Controls
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_773604.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .