Tender Value
₹43.4 L
EMD Value
₹87,000
Closing Date
18 Aug 2026, 6:00 pm
CWE AF Trivandrum
HQ CWE AF TRIVANDRUM HQ SAC IAF Complex Akkulam Thruvikkal Post Trivandrum 11
PROVN OF SUN SHED AT MAIN GATE AND DG SET FOR GDCC SERVER ROOM AT AFS SURYALANKA.
2026_MES_779924_1
82659/E8
Open Tender
Civil Works
Lump-sum
180 days
AGE I AF Suryalanka
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I AF Suryalanka
₹87,000
Yes
21 Jul 2026
21 Jul 2026
20 Aug 2026
21 Jul 2026
18 Aug 2026
11 Aug 2026
21 Jul 2026 - 3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | GENERAL SUMMARY
(Note : Schedule 'A' Part I 'Building/ Structure' is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6) | - | - | - | - |
| 2 | Schedule ‘A’ Part I “BUILDING/STRUCTURES ”
Design and construction of Pre Engineered Building (PEB) steel structure with
RCC M-30 foundation for SUN SHED of size 20m x 25m and minimum clear height 8.0m with pre painted galvalume sheet roofing 0.5mm thick (Hipped roof) complete all as specified and as shown in approved Architectural drawing / Approved structural drawing.
Notes:-
1. The contractor shall submit Architectural drawing & structural design of the building under Sch 'A' part I (prepared based on details given in tender documents) duly vetted by any IIT / NIT or any Govt engineering college within the time limit shown in schedule 'A' notes.
2. The sun shed (PEB structure) shall be made by encasing the existing entry control point, which has an approximate length of 17.0m and a height of 6.5m, at AF Station Suryalanka. The width of sunshed (20m) shall be parallel to the lengthwise side of existing existing entry control point)
3. The design shall be based on SBC 9.30 T/SQM at a depth of 1.5m.
4.The contractor shall visit the site (AF station Suryulanka) with prior permission, before quoting / preparation of design. The contractor shall not have any claim whatsoever arised due to non-visit of site at a later stage. | 1 | Job | - | - |
| 3 | GENERAL SUMMARY
(Note : Schedule 'A' Part II & III are prepriced by MES under Ser No. 04 & 05. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only) | - | - | - | - |
| 4 | Total of Schedule ‘A’ Part II “INTERNAL ELECTRIFICATION" | 1 | Lump sum | 1,13,731.75 | ₹1,13,731.75 |
| 5 | Total of Schedule ‘A’ Part III “EXTERNAL ELECTRIC SUPPLY ” | 1 | Lump sum | 98,364.36 | ₹98,364.36 |
| 6 | Sch 'A' Part- IV - MISCELLANEOUS ITEMS
(Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6) | - | - | - | - |
| 7 | Supply and laying of DWC flexible pipe of 75mm x 63 nominal outer/inner dia and 63 mm nom suitable for cable protection incl coupler and fixing accessories complete all as specified and directed. | 110 | RM | - | - |
| 8 | Supply, installation and testing of 30 kVA silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms including foundation etc complete all as specified and directed. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
BOQ_873583.xls
BOQ • 0.23 MB
Prepriced.pdf
Additional Documents • 0.43 MB
Tenderdocusmerged.pdf
Tender Documents • 2.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].