| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance 16 12A SWAMIJI ROAD NEAR SABUJ SANGHA KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹38.7 L (27.8%)Admitted-Finance 2239 1ST FLOOR GARIA STATION RD KALITALA VILLAGE TOWN GARIA CITY KOLKATA KOLKOTA WEST BENGAL 700084 INDIA | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | ₹1.8 Cr+₹38.7 L (27.8%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 1ST FLOOR FARIDPUR SHIVMANDIR LANE KAMALPUR PLOT BHAWANI PRASAD GHOSAL BUILDING BENACHITY VILLAGE TOWN DURGAPUR CITY DURGAPUR | - | - | Rejected-Technical Techno commercially not Qualified |
| Sl No | Description | Qty | Unit | TECHNO ENGINEERING L1 | P.E. ERECTORS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | BOILER EXTERNAL CLEANING BY AIR AND FIRE WATER. | 1 | LS | - | - |
| 2.00 | SCAFFOLDING OF FURNACE ZONE & PLATEN SH . | 1 | LS | - | - |
| 3.00 | SCAFFOLDING OF FSH, R/H, LTSH & ECONOMISER ZONE | 1 | LS | - | - |
| 4.00 | SCAFFOLDING FOR CHECKING OF HANGER & SUPPORTS OF BOILER AREA & CHECKING & REPAIRING OF BOILER BUCKSTAY | 1 | LS | - | - |
| 5.00 | CLEANING OF BOILER PRESSURE PARTS (FURNACE,PLSH,FSH,RH ZONE) BY H.P. WATER JET. | 1 | LS | - | - |
| 6.00 | CLEANING OF BOILER 2ND PASS BY FIRE WATER JET. | 1 | LS | - | - |
| 7.00 | De-METERING OF PRESSURE PARTS. | 1 | LS | - | - |
| 8.00 | LIFTING AND REFITTING OF LTSH MODULE | 12 | No. | - | - |
| 9.00 | LIFTING OR LOWERING AND TAKING OUTSIDE AT DESIGNATED REPAIRING SITE & REFITTING OF ECONOMISER MODULE. | 89 | No. | - | - |
| 10.00 | WELDING JOINTS FOR INSERTION OF TUBES IN ECONOMISER COIL,LTSH COIL & STEAM COOL WALL. | 4,500 | No. | - | - |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
18 Jul 2020, 5:00 pmClosed
The GM,STPS
Admin Bldg , STPS , Santaldih , Purulia 723146
Overhauling job of Boiler Pressure Parts of Unit 6 at STPS.
2020_WBPDC_283936_1
WBPDCL/STPS/NIT/E2090/20-21
Open Tender
Support/Maintenance Service
Item Rate
30 days
STPS, Santaldih
As stated in NIT.
2 documents required · 2 mandatory
₹3,540
THE WBPDCL
₹3.1 L
STPS , Santaldih
5 Aug 2020
3 Jun 2020
21 Jul 2020
4 Jun 2020
18 Jul 2020
18 Jun 2020
17 Jun 2020
Amount
BOILER EXTERNAL CLEANING BY AIR AND FIRE WATER.
SCAFFOLDING OF FURNACE ZONE & PLATEN SH .
SCAFFOLDING OF FSH, R/H, LTSH & ECONOMISER ZONE
SCAFFOLDING FOR CHECKING OF HANGER & SUPPORTS OF BOILER AREA & CHECKING & REPAIRING OF BOILER BUCKSTAY
CLEANING OF BOILER PRESSURE PARTS (FURNACE,PLSH,FSH,RH ZONE) BY H.P. WATER JET.
CLEANING OF BOILER 2ND PASS BY FIRE WATER JET.
De-METERING OF PRESSURE PARTS.
LIFTING AND REFITTING OF LTSH MODULE
LIFTING OR LOWERING AND TAKING OUTSIDE AT DESIGNATED REPAIRING SITE & REFITTING OF ECONOMISER MODULE.
WELDING JOINTS FOR INSERTION OF TUBES IN ECONOMISER COIL,LTSH COIL & STEAM COOL WALL.
WELDING JOINTS FOR INSERTION & RECTIFICATION OF TUBES IN FSH, PLSH, R/H COILS .
WELDING JOINTS FOR INSERTION OF FURNACE WALL TUBE INCLUDING SCREEN TUBE.
ALIGNMENT OF FSH,PSH,RH COILS.
RADIOGAPHY OF PRESSURE WELDING JOINTS.
LTSH HEADER STUB JOINT RECTIFICATION/REPLACEMENT.
ECONOMISER HEADER STUB JOINT RECTIFICATION/REPLACEMENT.
D. P. TEST OF STUB JOINTS & REGULAR WELDING JOINTS.
DEPOSITION OF WELD METAL ON TUBES, STUBS, HEADERS ETC.
STRESS RELIEVING FOR PRESSURE WELDING JOINT.
FABRICATION OF DIFFERENT SIZE BENDS.
REMOVAL AND REFITTING OF GUARD TUBE AND PERFORATED GUARD PLATE FOR LTSH, ECONOMISER , CAGE WALL , FURNACE WALL SCREEN TUBE, SPACER TUBE ,STEAM COOLED WALL.
OVERHAULING OF BOILER DRUM
OVERHAULING OF TROUGH SEAL
INSPECTION & REPAIRING OF PENT HOUSE, DOG HOUSE, DEAD CHAMBER,BOTH SIDE WINDBOX & ECO HOPPER.
SKIN CASING & FINS WELDING.
SERVICING & TRIVY TEST OF DRUM,MS,CRH & HRH SAFETY VALVES SAFETY RELIEV VALVES.
SAFETY VALVE SEAT CUTTING:
SERVICING OF SOOT BLOWER SAFETY VALVE.
TOTAL ASH CLEANING OF BOILER INTERNAL.
REMOVAL & REAPPLICATION OF REFRACTORY IN BOILER INTERNAL.
REMOVAL & REAPPLICATION OF INSULATION.
REPLACEMENT OF HP VALVE SIZE UP TO 50 MM.
REPLACEMENT OF HP VALVE SIZE 50 MM TO 100 MM.
REPLACEMENT OF HP VALVE SIZE ABOVE 100 MM.
BOILER TUBE OXIDE SCALE THICKNESS MEASUREMENT.
HIRING OF 01 NO HYDRA/CRANE (CAPACITY 14 TON ) WITH OPERATOR & FUEL.
ASSISTANCE JOB FOR IN PRESSURE PARTS AREA.
P.E. ERECTORS PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_526355.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .