Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹51.5 LAccepted-AOC | 1 | Accepted-AOC awarded to L1 | |
| 2 | 2₹55.4 L+₹3.9 L (7.60%)Rejected-Finance | 2 | Rejected-Finance Awarded to L1 | |
| 3 | 3₹67.2 L+₹15.7 L (30.6%)Rejected-Finance | 3 | Rejected-Finance Awarded to L1 |
Tender Value
₹53.6 L
EMD Value
₹1.1 L
Closing Date
3 Jan 2020, 3:00 pmClosed
AGM ELECTRICAL
AGM, O/o ENGINEERING ELECTRICAL, AIRPORTS AUTHORITY OF INDIA, VIJAYAWADA AIRPORT
Construction of New Fire Station at Vijayawada Airport. SH Electrical Works
2019_AAI_38719_1
AAI/BZ/ENGGE/AGM/NIT14/2019
Open Tender
Electrical Works
Item Rate
120 days
Airports Authority of India, Vijayawada Airport
As per NIT Criterai
9 documents required · 9 mandatory
₹1,180
AIRPORTS AUTHORITY OF INDIA
₹1.1 L
11 Sept 2020
24 Dec 2019
7 Jan 2020
24 Dec 2019
3 Jan 2020
25 Dec 2019
24 Dec 2019 - 30 Dec 2019
Amount
Supply of 125/103.5mm dia HDPE pipe PN4,PE63 ISI marked conforming to IS 4984, Part II and Laying direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective convering with all accessories, cutting, jointing etc. complete as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1KV grade of size 185 sq. mm and upto 400 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 35 sq.mm. in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of size from 185 sq. mm and upto 400 sq. mm. in the existing masonry open duct as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of size upto 35 sq. mm. in the existing masonry open duct as required.
Laying and fixing of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
Providing, laying and fixing following dia G.I. pipe (medium class) complete with G.I. fittings for road crossing including bitumin cutting of suitable width and depth of 300mm and finished with concrete (1:2:4) of 150mm thick etc. as required a) 50mm
Providing, laying and fixing following dia G.I. pipe (medium class) complete with G.I. fittings for road crossing including bitumin cutting of suitable width and depth of 300mm and finished with concrete (1:2:4) of 150mm thick etc. as required a) 150mm
Supplying and making end termination with Double Compression brass gland for 3.5C 185 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1kv grade as required.
Supplying and making end termination with Double Compression brass gland for 4C 16 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured Copper conductor cable of 1.1kv grade as required.
Supplying and making end termination with Double Compression brass compression gland for 4C 16 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1kv grade as required.
Supplying and making end termination with double compression brass compression gland for 2C 10 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1kv grade as required.
Supply and making outdoor straight through cable joint with heat shrinkable cable jointing kit including ferrules and other jointing materials for 3.5C 185 Sq.mm. PVC/XLPE insulated PVC sheathed armoured Aluminium conductor power cable of 1.1KV grade.
Supply ,Installtion, Testing And commisioning of Indoor MV Feeder Pillar Panel completely made up of 14 SWG CRCA sheet steel, door dust tight, vermin proof, totally enclosed, cubicle type, floor mounting, free standing, including providing and fixing 250A Four Pole Aluminium Bus bar with all accessories suitable for operation at 433 V, 3 phase, 4 wire, 50 Hz, A.C. Power Supply System complete with all accessories, interconnection, connection, earthing, painting, grouting, providing pedastal, Cable Entry provision etc. complete as required and comprising the following: a. 250A, 36 KA, 4P MCCB with Microprocessor based releases as incomer with R,Y,B,ON, OFF, Trip indication lamps, resin cast CT's with multifuction meter (Schheider EM 6459 or Equivalent)- 2 sets as incomer b. 250A, 4P MCCB Isolator as buscoupler with ON, OFF and three locks two key mechanical interlock- 1 set c. 63A, 25KA, 4P MCCB with TM based releases with ON, OFF, Trip indication lamps as outgoing - 8 Sets. As outgoing d. 32A, 25KA, 4P MCCB with TM based releases with ON, OFF, Trip indication lamps as outgoing - 8 Sets. As outgoing e. 32A, 25KA, 4P MCCB with TM based releases with ON, OFF, Trip indication lamps 4P Contactor of 40 Amps rating and 24 Hours Digital Timer for Automatic Control, ON/OFF/TRIP Indication Lamps as required.- 2 sets. As outgoing f.with all necessary accessories etc. complete as required.
Providing and Fixing 6 SWG dia G.I. wire for loop earthing along with existing cable as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as required.
Earthing with GI earth pipe 4.5 meter long ,40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangemnt and watering pipe etc. with charcoal/coke and salt as required.
Supplying and Fixing Cable Route Marker with Cement concrete 1:2:4 (1 Cement: 2 Coarse Sand : 4 graded stone aggregate 20mm nominal size) of size 50cmx60cm at the bottom and 50cmx50cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supply, installation, testing & commissioning of fully autonomous, CPRI tested, Early Streamer Emission Lightening Conductor (ESELC) having gain in triggering time (∆t) of minimum 60 micro sec. and radius of protection of 79 metres in Level 1 protection zone at 6Mtr. height mast (2 meter FRP mast 68mm OD, 4mm wall thick and 4 Mtr. GI B class pipe) along with all other accessories to protect the building & other structures from lightening strikes.
Supplying & laying of 70 sq.mm single core flexible copper down conductor cable from Air terminal to earth pit i/c all accessories like PVC sleeves,Saddles/clamps etc. required .complete as per specification and as required.
SITC of Lightening Transient Event counter resettable 6 digit LCD displace with in-built lithium battery in IP67 enclosure with transparent Lid, mounting arrangements etc. as complete as per specification and as required
Providing & creating of earth pits using CPRI tested and certified advanced chemical earth rod made of Copper tube of 2.5" dia, 2.4m long, 1.6mm thickness, installed vertically or horizontally as per the site conditions complete with flanges, bends and top cover dully backfilled with Earth enhancing compound of not less than 20 Kgs. alongwith required materials as per the soil condition to achieve earth resistance less than 1 ohm with one no. of heavy duty plastic inspection chamber including excavation & refilling complete etc. as required.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Supply of 80 W SMD LED floodlight with pressure die-cast aluminium housing suitable to fix on wall surface,inside canopy Low highbay application with IP65 Protection with sealed toughened glass cover,SMD LED with secondary lens, module with driver, etc complete as required. ( Similar to BAJAJ make BGPPR80WLEDVX or equivalent).
Supply of 30W SMD LED floodlight with pressure die-cast aluminium housing suitable to fix on wall surface,inside canopy Low highbay application with IP65 Protection with sealed toughened glass cover,SMD LED with secondary lens, module with driver, etc complete as required. ( Similar toBAJAJ make BJFL30WLED or equivalent).
Supply of 18 W LED Recessed Mounting round LED downlighter with doom shape opal difuser suitable for indoor application. high power LED luminaire PDC Aluminium Housing Downlights suitable to fix on wall surface, LED Luminaire, module with driver, Suitable housing etc complete as required. (Similar to BAJAJ make BGSLO SLEEK 18W WH RD or equivalent).
Supply of 20 W LED batten type T5 tubelight for surface,Al. housing with frosted PMMA/PC diffuser, High transmissitivity Elegant and sleek designed LED Batten etc complte as required. (Similar to BAJAJ make LEDBCLAB20W or equivalent).
Supply of 35/36W LED Street Light Fitting suitable for operate on 240V, 50Hz, AC Supply housed in pressure Die-Cast/Extruded Aluminium Alloy, Toughened glass with IP66 protection suitable for fixing on pole etc. complete as required. The Fitting shall have separate compartment for LEDs & electronic driver, operating voltage 140-270 V with Surge Protection of 4KV. (similiar to BAJAJ model No. BRTFG 36W LED)
Supply and fixing of Aviation Obstruction Light suitable to operate on 240V, 50Hz complete as required. The Fitting shall have compartment for LEDs & electronic driver, AC Supply Aluminium housing ,Polycorbonate enclosure,, with IP66 protection ,including suitable 1/2 inch mm GI B-class pipe of length 1.5 mtr with reducer and suitable foundation,with 3 Core 2.5 Sqmm PVC insulated flexiable copper cable to nearest switch board. so as to fix on existing Fire Tower etc as required.(similiar to BAJAJ model No. BGAV302LED)
Installation, testing and commissioning of pre-wired,LED street fitting with 1.5 mtr length , 25mm GI pipe Class B with suitable bend of all types,complete with all accessories etc. directly on wall, including clamps,connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Installation, testing and commissioning of pre-wired, LED fitting of all types,complete with all accessories etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Installation, testing and commissioning of pre-wired, 30 watt flood LED light fitting on sign board ,complete with all accessories etc. on hanging position so as to illuminate sign board clearly ,clamping ,supports made up of with 25 mm B class GI pipeup to 2.5 Mtr length with suitable bend ,including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required
Supply of Ceiling fan 1200 mm sweep, 5 star rated, Energy Efficient, air delivery - 210CMM complete with 300 mm down road, canopies, shackles, blades, but without regulator suitable to operate on single phase, 230V,50Hz A.C supply etc complete as required
Supply of heavy duty Exhaust fan of 450mm sweep , 1400 RPM, power consumption max 82W, air delivery-1900 cum/hr, noice delivery 45-50db with louvers including all accessories and suitable to operate on single phase, 230V , 50 Hz A.C Supply, etc complete as required.
Supply and fixing of Wall mounting heavy duty fan with 400 mm size, Energy Efficient, shackles, blades,with suitable speed controller regulator suitable to operate on single phase, 230V,50Hz A.C supply etc complete wiring etc as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Numbering of ceiling fan/ exhaust fan/LED fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and Fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required
Supply and Fixing of 1.5 KVA UPS , 5 Star rated with trolley & SMF battery of minimum back up 2Hours suitable to operate on single phase 230V, 50Hz frequency etc as required.
Supply and Fixing Fire bell of minimum Audible range 3 KM suitable to operate on Single phase,230 v,50HZ with inbuit motor etc., as per site requirement. (Similar to Make: National)
Supply of 40mm dia HDPE pipe PN4,PE63 ISI marked conforming to IS 4984, Part II and Laying direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective convering with all accessories, cutting, jointing etc. complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.(a) 1X6Sq.mm
Supply and Fixing of 15 Litre Capacity Water Heater(Gyser) with Copper Heating Element Suitable to operate 220V,with 3 Level Protection, 5 Star Rated etc., Complete as per Site requirement (Model No: V-GURAD EMA 15 L WHITE)
Supplying and fixing of 4 way, Double door, horizontal type TPN, sheetsteel, PPI(Per Phase Isolation withsub-Incomer) distribution board, 415 volts,IP43, on surface/ recess, complete with Insulated tinned copper bus bar, neutral bus bar, earth bar, din rail, interconnecting wire set,Blank plates, powder coated including earthing etc. as required (L&T Model: DBHPI004DD or equivalent)
Supplying and fixing of 6 way, Double door, horizontal type TPN, sheetsteel, PPI(Per Phase Isolation withsub-Incomer) distribution board, 415 volts,IP43, on surface/ recess, complete with Insulated tinned copper bus bar, neutral bus bar, earth bar, din rail, interconnecting wire set,Blank plates, powder coated including earthing etc. as required (L&T Model: DBHPI006DD or equivalent)
Supplying and fixing of 8 way, Double door, horizontal type TPN, sheetsteel, PPI(Per Phase Isolation withsub-Incomer) distribution board, 415 volts,IP43, on surface/ recess, complete with Insulated tinned copper bus bar, neutral bus bar, earth bar, din rail, interconnecting wire set,Blank plates, powder coated including earthing etc. as required (L&T Model: DBHPI008DD or equivalent)
Supplying and fixing 40A rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/ 415 volts, 10 kA, “B/C” curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 amps rating, 240/ 415 volts, 10 kA, “B/C” curve, 300mA Sensitivity Earth Leakage circuit breaker suitable for inductive load of Double pole in the existingMCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps rating, 240/ 415 volts, 10 kA, “B/C” curve, 100mA Sensitivity Earth Leakage circuit breaker suitable for inductive load of Double pole in the existingMCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure(IP 30 - Metal Door) on surface/ recess along with (6-32)amps 240 volts “B” curve DP MCB complete with connections, testing andcommissioning etc. as required.
Supply and installation of Water cooler of capacity 80 lt storage, 60ltrs per hour cooling capacity self contained storage type drinking water cooler suitable for operation on 230 v +/- 10 %, 50 Hz, single phase A.C. supply. Water Cooler with stainless Steel Storage Tank, All the four sides panel fitted with Stainless steel sheet (SS 304), with inbuilt RO,UV, 50LPH and 7 stage purification, unit fitted with suitable Compressors with faucets etc..(Make: BLUE STAR Model No: SWCSDLX6080UVROE or equivalent from approved makes).
SITC of Borewell type 7.5HP/5.5KW submersible Pump, 160LPM @90m, water filled cooling type, with SS strainer, SS Body, Noryl Impellers using anti-friction bearing, energy efficient type operated on 415V, 3 Phase,50Hz power for installation into 6' dia borewell complete etc as required. Supply and installation of Suitable star/delta starter and laying cable, conncetions between starter and motor etc as per site requirement. (Make and model :Kirloskar 125HHF0806 or equivalent)
SITC of 7.5HP/5.5KW Monoblock Pump, 180LPM @36m head, water filled cooling type, with SS strainer, CS Body, CI/Bronze SS Impellers , energy efficient type operated on 415V, 3 Phase,50Hz power complete etc as required. Supply and installation of Suitable star/delta starter and laying cable between starter and motor . (impeller - bronze) (Make and model : Kirloskar KDS844E or equivalent)
Supply of Flat Three Core X 4.0 Sq.mm PVC insulated & PVC sheathed,Copper conductor Industrial cable of 1.1 KV Grade confirming to IS-694 for Submersible pump motors, complete as required.
Supply of 1.5TR (Minimum ISEER 4.5) Split Inverter Type Air Conditioners with 5 Star Rating, fitted with Hermetically Sealed, Rotary/ScrollCompressors, Operating on Refriegerant R410A eco friendly green gas suitable for floor mounting / wall mounting / ceiling mounting, Conforming to IS:1391 (part-2)/92 (Amdt.1) (Except power consumption norms) suitable for operation on 230 V, 50 Hz, Single Phase, AC Supply capable of performing: Dehumidifying, Air Circulating, Filtering, drain and including supply of refrigerant pipe and drain pipe (up to 3 Meters as per site condition) , Outdoor Unit MS support stand as per site requirement.
Supply of 2 TR (Minimum ISEER 4.5) Split Inverter Type Air Conditioners with 5 Star Rating, fitted with Hermetically Sealed, Rotary/ Scroll Compressors, Operating on Refriegerant R410A eco friendly green gas suitable for floor mounting / wall mounting / ceiling mounting, Conforming to IS:1391 (part-2)/92 (Amdt.1) (Except power consumption norms) suitable for operation on 230 V. 50 Hz. Single Phase, AC. Supply capable of performing: Dehumidifying, Air Circulating, Filtering, drain and including supply of refrigerant pipe and drain pipe (up to 3 Meters as per site condition) , Outdoor Unit MS support stand as per site requirement.
Installation of Testing Commissioning of Split Acs upto 2 TR including wall cutting, laying of Refrigerant and draing pipe and electrical cable of standard length and making good the wall opening etc. complete as required.
Laying of Extra copper Refrigerant Piping with insulation along with Electrical Cable from Indoor to Outdoor including beyond 3.0 Meters etc. Complete as required as per tonnage requirement of respective split ac Complete as required. . [Suitable for 2 TR]
Laying of Extra Drain piping using hard PVC of diameter 1/2 inch beyond 3.0 Meters etc. Complete as required.
Supply of 2.5 TR Verti Cool (Floor Mounted) Split Type Air Conditioners, Light Commercial, fitted with Hermetically Sealed/Rotary/ Scroll/ Reciprocating Compressors, Operating on Refriegerant R410A/R-22/R-32 green gas suitable for Floor Mounting, Conforming to IS:1391 (part-2)/92 (Amdt.1) (Except power consumption norms) suitable for operation on 415 V, 50 Hz. 3 Phase, AC. Supply capable of performing: Dehumidifying, Air Circulating, Filtering, drain and, Outdoor Unit MS support stand as per site requirement.
Installation of Testing Commissioning of Verti Cool (Floor Mounted) Split AC of 2.5 TR including Wall Cutting, Hole Cutting , Plastering and making wall good condition & electrical connection with wire, complete as required.
Supply and Laying of Copper Pipe size Light Commercial Mega Split 3TR AC as per site requirement along with Electrical Cable. (a) 3/8 Inches - Liquid Line (b) 5/8 Inches - Suction Line
CHENNAI ENGINEERING SERVICES
Shantha ELectricals and Engineers Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .