Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹33.7 L+₹1.7 L (5.40%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.4 L+₹3.5 L (10.8%)Rejected-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹37.1 L+₹5.1 L (15.8%)Rejected-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹37.6 L+₹5.6 L (17.5%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jul 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
MANNING OF FF PH AT MOV NEW SITE,BPH AND SEWAGE PH AT M PETA, NEW AND OLD MPETA, ASHOKA PARK AND OPERATION OF DG SETS AND CERTAIN REPAIRS TO WS DISTRIBUTION SYSTEM AT MPETA, MOV, WED, NAMAC, PALLAVA PARK, NSB UNDER AGE E/M No. I OF GE (U-II) VSKP
2020_MES_342716_1
8695
Open Tender
Electrical Maintenance Service
Item Rate
330 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹90,000
Yes
8 Jul 2020
5 Jun 2020
3 Jul 2020
5 Jun 2020
2 Jul 2020
19 Jun 2020
Amount
Manning and Operation of booster pump house at M' Peta, operation of DG set, operation of sewage upmp house at 'M' Peta and controlling of distribution valves as per timings at Booster Pump House M' Peta, residential Qtrs M' Peta and Ashoka Park in three shifts per day of 08 hrs each including holidays and Sundays complete all as specified and as directed by Engineer-In-Charge. Man Power: 01 Skilled operator and 01 Unskilled per shift at Booster Pump House M' Peta Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Manning and operation of pump house MO(V), Fire Fighting Pump House at MO(V) and controlling of distribution valves as per timings at Pump House MO(V), residential Qtrs MO(V), NSB area, NAMAC area in three shifts per day of 08 hrs each including holidays and Sundays complete all as specified and as directed by Engineer-In-Charge. Man Power: 01 Skilled operator per shift at Fire fighting Pump House at MO(V) Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Manning and operation and controlling of distribution valves as per timings at Pump House MO(V), residential Qtrs MO(V), NSB area, NAMAC area, Ahoka Park valves in three shifts per day of 08 hrs each including holidays and Sundays including arresting leakages by replacing gland packing, cleaning and maintaining off all valve chambers, ensure proper locking of valve chambers complete all as specified and as directed by Engineer-In-Charge. Man Power: One Valve Man (Semi-Skilled) per shift Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Note for SL item No. 1 to 3: The quoted rate is inclusive of following :- (a) Filling the sump and pumping water to various areas as directed by Engineer-in-Charge. (b) Operation of DG Set for electric supply during power failure of (APEPDCL) electric supply. (c) Attending minor break downs such as replacing of fan belt, gland rope, gland bolts and nuts etc., (d) Supply and filling of distilled water and electrolyte in batteries and coolant in radiators, recharging of batteries as and when required.
(e) After opening the delivery valves the unskilled trades man/helper should ensure that the water is reaching in each bldg. (f) unskilled trades man/helper should control over flow of water in each building during the supply of water. (g) Unskilled trades man/helper shall maintain installations neat and clean. (h) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Supply only chlorine gas supplied in 100 kg cylinders for water treatment. Make: Andhra Sugars or its equivalent make approved by State Jal Board as approved by GE Note: (i) Testing the cylinders, and repair to outlet valves of cylinders and maintain the gas control and regulating system shall be the responsibility of Contractor and the rate is deemed to be included for the same (ii) Chlorine gas will be supplied in 100 Kg cylinder only.
Supply only calcium based, high strength chlorination chemical for disinfectant, in granual form for water treatment in factory sealed non returnable HDPE containers (40 to 50 Kg each) having chlorine concentration level of 70% complete all as specified and as directed. Make: Rayalaseema/ Declibac or its equivalent make as approved by E-in-C's branch and approved by GE.
Supply only stable bleaching powder (SBP) (calcium hypochlotite) Grade I, availability chlorine 34% min, stability 1/15 max, moisture 0.3% max, conforming to IS -1065. Make: Lion / Vikram
Maintenance of Chloronome cylinders of 100/900 kgs including periodical checking for leakage, rectifying the leakage, removing the empty cylinder from the chloronome plant and connecting the new cylinder as and when required complete all as specified and as directed. The quoted rate includes the following :- (a) Maintain the chlorine content of the treated water as per IS. (b) Maintain the record of water testing. (c) Replacing of damaged copper tubing of required size and length for connecting the cylinder to chloronome plant as and when required. (d) Connect / inject of chlorine gas to gravity feed gaseous chloronome plant.
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings of size 80 mm complete all as specified and directed by Engr-in-Charge.
All as per SI item No.8 above but 100 mm dia
All as per SI item No.8 above but 150 mm dia
All as per SI item No.8 above but 200 mm dia
All as per SI item No.8 above but 250 mm dia
All as per SI item No.8 above but 300 mm dia
All as per SI item No.8 above but 400 mm dia
Supply and laying DI K9 water supply pipe lines of size 200 mm bore flanged end having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329 including taking down old DI water mains complete all as specified and directed by Engineer-in-Charge. NOTE: (i) Earth work will be measured and paid seperately.
All as per SI item No.15 above but 150 mm dia
All as per SI item No.15 above but 100 mm dia
Supply & fix spindle of sluice valve of 80 mm bore, made out of En-8 steel with check nuts made out of MS/CI material, with and including replacing perished gland packing, rubber gasket, bolts and nuts including taking down old unserviceable spindle complete all as directed by Engineer-in-charge.
All as per Sl. Item No.18 above but 100/150 mm bore
All as per Sl. Item No.18 above but 200/250 mm bore
All as per Sl. Item No.18 above but 300 mm bore
All as per Sl. Item No.18 above but 400 mm bore
All as per Sl. Item No.18 above but 450 mm bore
M & L for Jungle cleaning by cutting and clearing away all grass vegetation, wild growth, sapling, shrubs, brushwoods, under growth roots, cutting of bushes, tree trunk of girth not execeeding 30 cm, cutting of trunk, portion protuding over ground, filling holes and leveling of ground and removing unserviceable materials to a distance n.exe 50m, compelte all as speicified
Supply replace Nuts & bolts, gland eye bolts of different sizes complete all as directed.
Supply only rubber sheet 3/4 mm thick
Supply only rubber sheet 6/8 mm thick
Supply and replace 125 mm bore CI foot valve flanged type with necessary rubber gasket, bolts, nuts and washers complete all specified and directed.
Supply and replace 100 mm bore CI foot valve flanged type with necessary rubber gasket, bolts, nuts and washers complete all specified and directed.
Supply and fix 25 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed.
All as per SL item No.30 above but 40 mm dia
All as per SL item No.30 above but 50 mm dia
All as per SL item No.30 above but 80 mm dia
Supply and laying GI pipes medium grade of 20 mm dia with all fittings and fixtures complete fixed to wall and ceilings or laid in floors including taking down unserviceable one all as specified and directed.
All as per SL item No.34 above but of size 25 mm dia.
All as per SL item No.34 above but of size 40 mm dia.
All as per SL item No.34 above but of size 50 mm dia.
All as per SL item No.34 above but of size 80 mm dia.
Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, laying cables and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50m distance and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed.
M&L for PCC 1:3:6, type C1 (using 20 mm graded granite stone aggregate) for making good the surface where road cutting/ hard standing/ paths complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) in bases/ pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC complete all as specified and directed.
M&L masonary valve chamber of size 900x900x900 mm (internal dimensions) and including necessary excavation and earth work in any type of soil, 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15 mm thick in CM 1:4, 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) coping, 50 x 50 x 6 mm thick MS angle iron, 5 mm thick MS plate cover with locking arrangement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable compete all as specified and directed.
Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, barred iron doors, ladders, walk ways, railings, framework of water tanks and similar work conforming to Fe. 290 Gde-E-165 and including dismantling of existing framed work complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description, not exc 10 cm width or girth, and including applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
M & L for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment from wall and ceiling and applying two coat of exterior weather coat paint over a coat of primer after finishing the surface with two coats of putty (Birla/JK) to get smooth finish complete all as specified and directed.
M&L for complete removal of existing treatment from wall and applying two coat of oil bound distemper over a coat of primer after finishing the surface with two coats of putty (Birla/JK) to get smooth finish complete all as specified and directed.
M & L Preparation of old painted steel/ concrete surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
M&L preparing of new/ old or untreated plastered surfaces and applying two coats of antifungal paint over one coat of primer on walls and ceilings etc complete all as specified and as directed.
Supply only chlorine test kit with coloured sample complete with all testing fitments and OT solution in rexine finished box complete all as specified and directed by Engineer-in-Charge,
Supply & replace STEQUA PURITY VERIFIER 41021: 1.Purity Verifier 41021 set, containing: 1 Comparator with lid, 30 tablets X pH RAPID (Item Code: PVPH 3041021), 30 tablets X Chlorine RAPID (Item Code: PVPH 3041021), 1 instruction sheet, 1 plastic box, pH range: 6.8-7.0-7.2-7.4-7.6-7.8-8.0-8.2, Chlorine range: 0.1-0.3-0.4-0.5-0.6-0.8-0.9-1.0-1.5-2.0-3.0-4.0-5.0-6.0 complete all as specified and directed by Engr-in-Charge.
Supply only PVPH 41021: Packet of 100 tablets pH RAPID for STEQUA Purity Verifier 41021
Supply only PVFC 41021. Packet of 100 tablets chlorine RAPID for STEQUA Purity Verifier 41021
Supply and replace DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, "Y" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 150 mm bore complete all specified and as directed.
All as per SL item No.56 above but of dia 200 mm to 450 mm
GVR CONSTRUCTIONS
Bhuvaneswari Electrical Works
Prasad and Suresh Constructions
lakshmi Engineering Works
SREE GAYATRI INFRA
SRIESWARI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .